title | description | addedAt | pageClass |
---|---|---|---|
Smartenit 4040B control via MQTT |
Integrate your Smartenit 4040B via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2020-04-08 17:49:06 UTC |
device-page |
Model | 4040B |
Vendor | Smartenit |
Description | Wireless metering 30A dual-load switch/controller |
Exposes | switch (state), power, energy, linkquality |
Picture |
How to use device type specific configuration
-
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.
The current state of this switch is in the published state under the state_l1
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l1": "ON"}
, {"state_l1": "OFF"}
or {"state_l1": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l1": ""}
.
The current state of this switch is in the published state under the state_l2
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l2": "ON"}
, {"state_l2": "OFF"}
or {"state_l2": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l2": ""}
.
Instantaneous measured power.
Value can be found in the published state on the power
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Sum of consumed energy.
Value can be found in the published state on the energy
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is kWh
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.