title | description | addedAt | pageClass |
---|---|---|---|
Legrand 412171 control via MQTT |
Integrate your Legrand 412171 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2020-12-30 11:31:00 UTC |
device-page |
Model | 412171 |
Vendor | Legrand |
Description | DIN contactor module (BTicino FC80CC ) |
Exposes | switch (state), power, device_mode, auto_mode, linkquality |
Picture |
How to use device type specific configuration
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Instantaneous measured power.
Value can be found in the published state on the power
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power": ""}
.
It's not possible to write (/set
) this value.
The unit of this value is W
.
Switch: allow manual on/off, auto uses contact's C1/C2 wired actions for Peak/Off-Peak electricity rates.
Value can be found in the published state on the device_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"device_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"device_mode": NEW_VALUE}
.
The possible values are: switch
, auto
.
Off/auto/on (override) (works only if device is set to "auto" mode).
Value can be found in the published state on the auto_mode
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"auto_mode": NEW_VALUE}
.
The possible values are: off
, auto
, on_override
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.