Skip to content

Latest commit

 

History

History
71 lines (56 loc) · 3.16 KB

4512702.md

File metadata and controls

71 lines (56 loc) · 3.16 KB
title description addedAt pageClass
Namron 4512702 control via MQTT
Integrate your Namron 4512702 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2020-03-16 20:23:37 UTC
device-page

Namron 4512702

Model 4512702
Vendor Namron
Description Zigbee 1 channel switch K4
Exposes battery, action, linkquality
Picture Namron 4512702

Notes

Pairing

  1. Remove the remote from previous zigbee network if it has already been added to it, otherwise pairing will fail. Please refer to the part "Factory Reset".
  2. From your zigbee controller or hub interface, choose to add device or accessory and enter Pairing mode as instructed by the controller.
  3. Press and hold down top two buttons (channel 1 ON and OFF) until LED indicator turns on.
  4. Immediately short press to search nearby network, indicator flashes every 1 second, 20 seconds timeout if there is no network. Indicator will then blink 5 times quickly for successful pairing.

Factory Reset

  1. Press and hold down top two buttons (channel 1 ON and OFF) until LED indicator turns on
  2. Immediately short press 5 times continuously, indicator flashes 3 times quickly to indicate successful reset.

Options

How to use device type specific configuration

  • simulated_brightness: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Example:
simulated_brightness:
  delta: 20 # delta per interval, default = 20
  interval: 200 # interval in milliseconds, default = 200

Exposes

Battery (numeric)

Remaining battery in %. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Action (enum)

Triggered action (e.g. a button click). Value can be found in the published state on the action property. It's not possible to read (/get) or write (/set) this value. The possible values are: on, off, brightness_move_up, brightness_move_down, brightness_stop, brightness_step_up, brightness_step_down.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.