title description addedAt pageClass
Schneider Electric 545D6102 control via MQTT
Integrate your Schneider Electric 545D6102 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2021-07-01 18:17:29 UTC
device-page

Schneider Electric 545D6102

Model 545D6102
Vendor Schneider Electric
Description LK FUGA wiser wireless dimmer
Exposes light (state, brightness, level_config), ballast_minimum_level, ballast_maximum_level, dimmer_mode, action, linkquality
Picture Schneider Electric 545D6102

Options

How to use device type specific configuration

  • transition: Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to 0 (no transition). The value must be a number with a minimum value of 0

  • simulated_brightness: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Example:

simulated_brightness:
  delta: 20 # delta per interval, default = 20
  interval: 200 # interval in milliseconds, default = 200

Exposes

Light (l1 endpoint)

This light supports the following features: state, brightness, level_config.

  • state: To control the state publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state_l1": "ON"}, {"state_l1": "OFF"} or {"state_l1": "TOGGLE"}. To read the state send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"state_l1": ""}.
  • brightness: To control the brightness publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"brightness_l1": VALUE} where VALUE is a number between 0 and 254. To read the brightness send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"brightness_l1": ""}.

Ballast_minimum_level (numeric, l1 endpoint)

Specifies the minimum light output of the ballast. Value can be found in the published state on the ballast_minimum_level_l1 property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"ballast_minimum_level_l1": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"ballast_minimum_level_l1": NEW_VALUE}. The minimal value is 1 and the maximum value is 254.

Ballast_maximum_level (numeric, l1 endpoint)

Specifies the maximum light output of the ballast. Value can be found in the published state on the ballast_maximum_level_l1 property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"ballast_maximum_level_l1": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"ballast_maximum_level_l1": NEW_VALUE}. The minimal value is 1 and the maximum value is 254.

Dimmer_mode (enum, l1 endpoint)

Controls Capacitive or Inductive Dimming Mode. Value can be found in the published state on the dimmer_mode_l1 property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"dimmer_mode_l1": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"dimmer_mode_l1": NEW_VALUE}. The possible values are: RC, RL.

Action (enum)

Triggered action (e.g. a button click). Value can be found in the published state on the action property. It's not possible to read (/get) or write (/set) this value. The possible values are: on, off, brightness_move_up, brightness_move_down, brightness_stop, recall_*.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.