title | description | addedAt | pageClass |
---|---|---|---|
AduroSmart 81848 control via MQTT |
Integrate your AduroSmart 81848 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2021-11-30 12:10:17 -0800 |
device-page |
Model | 81848 |
Vendor | AduroSmart |
Description | ERIA smart plug (with power measurements) |
Exposes | switch (state), power, current, voltage, linkquality |
Picture |
How to use device type specific configuration
-
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number. -
power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number. -
current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number. -
voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Instantaneous measured power.
Value can be found in the published state on the power
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.