title description addedAt pageClass
TuYa D3-DPWK-TY control via MQTT
Integrate your TuYa D3-DPWK-TY via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2020-08-11 22:17:44 UTC
device-page

TuYa D3-DPWK-TY

Model D3-DPWK-TY
Vendor TuYa
Description HVAC controller
Exposes climate (current_heating_setpoint, local_temperature, system_mode, running_state), linkquality
Picture TuYa D3-DPWK-TY

Exposes

Climate

This climate device supports the following features: current_heating_setpoint, local_temperature, system_mode, running_state.

  • current_heating_setpoint: Temperature setpoint. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"current_heating_setpoint": VALUE} where VALUE is the °C between 5 and 30. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"current_heating_setpoint": ""}.
  • local_temperature: Current temperature measured on the device (in °C). Reading (/get) this attribute is not possible.
  • system_mode: Mode of this device. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"system_mode": VALUE} where VALUE is one of: off, auto, heat. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"system_mode": ""}.
  • running_state: The current running state. Possible values are: idle, heat, cool. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"running_state": ""}.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.