forked from vilppuvuorinen/pymelcloud
-
Notifications
You must be signed in to change notification settings - Fork 8
Expand file tree
/
Copy pathtest_atw_properties.py
More file actions
301 lines (267 loc) · 10.5 KB
/
test_atw_properties.py
File metadata and controls
301 lines (267 loc) · 10.5 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
"""Ecodan tests."""
import pytest
import src.pymelcloud
from src.pymelcloud import DEVICE_TYPE_ATW
from src.pymelcloud.atw_device import (
OPERATION_MODE_AUTO,
OPERATION_MODE_FORCE_HOT_WATER,
STATUS_HEAT_WATER,
STATUS_HEAT_ZONES,
STATUS_UNKNOWN,
ZONE_OPERATION_MODE_COOL_FLOW,
ZONE_OPERATION_MODE_COOL_THERMOSTAT,
ZONE_OPERATION_MODE_CURVE,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_STATUS_HEAT,
ZONE_STATUS_IDLE,
ZONE_STATUS_UNKNOWN,
AtwDevice,
)
from .util import build_device
def _build_device(device_conf_name: str, device_state_name: str) -> AtwDevice:
device_conf, client = build_device(device_conf_name, device_state_name)
return AtwDevice(device_conf, client)
@pytest.mark.asyncio
async def test_1zone():
device = _build_device("atw_1zone_listdevice.json", "atw_1zone_get.json")
assert device.name == "Heater and Water"
assert device.device_type == DEVICE_TYPE_ATW
assert device.temperature_increment == 0.5
assert device.operation_mode is None
assert device.operation_modes == [
OPERATION_MODE_AUTO,
OPERATION_MODE_FORCE_HOT_WATER,
]
assert device.tank_temperature is None
assert device.status is STATUS_UNKNOWN
assert device.target_tank_temperature is None
assert device.target_tank_temperature_min == 40
assert device.target_tank_temperature_max == 60
assert device.flow_temperature_boiler == 25
assert device.return_temperature_boiler == 25
assert device.mixing_tank_temperature == 0
assert device.holiday_mode is None
assert device.wifi_signal == -73
assert device.has_error is False
assert device.error_code is None
zones = device.zones
assert len(zones) == 1
assert zones[0].name == "Zone 1"
assert zones[0].zone_index == 1
assert zones[0].room_temperature is None
assert zones[0].target_temperature is None
assert zones[0].flow_temperature == 57.5
assert zones[0].return_temperature == 53.0
assert zones[0].target_flow_temperature is None
assert zones[0].operation_mode is None
assert zones[0].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
]
assert zones[0].status == ZONE_STATUS_UNKNOWN
await device.update()
assert device.operation_mode == OPERATION_MODE_AUTO
assert device.status == STATUS_HEAT_ZONES
assert device.tank_temperature == 52.0
assert device.target_tank_temperature == 50.0
assert device.flow_temperature_boiler == 25
assert device.return_temperature_boiler == 25
assert device.mixing_tank_temperature == 0
assert device.immersion_heater_enabled is False
assert device.holiday_mode is False
assert device.wifi_signal == -73
assert device.has_error is False
assert device.error_code == 8000
assert zones[0].room_temperature == 27.0
assert zones[0].target_temperature == 30
assert zones[0].target_flow_temperature == 60.0
assert zones[0].operation_mode == ZONE_OPERATION_MODE_HEAT_FLOW
assert zones[0].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
]
assert zones[0].status == ZONE_STATUS_HEAT
@pytest.mark.asyncio
async def test_2zone():
device = _build_device("atw_2zone_listdevice.json", "atw_2zone_get.json")
assert device.name == "Home"
assert device.device_type == DEVICE_TYPE_ATW
assert device.temperature_increment == 0.5
assert device.operation_mode is None
assert device.operation_modes == [
OPERATION_MODE_AUTO,
OPERATION_MODE_FORCE_HOT_WATER,
]
assert device.tank_temperature is None
assert device.status is STATUS_UNKNOWN
assert device.target_tank_temperature is None
assert device.target_tank_temperature_min == 40
assert device.target_tank_temperature_max == 60
assert device.flow_temperature_boiler == 25
assert device.return_temperature_boiler == 25
assert device.mixing_tank_temperature == 0
assert device.holiday_mode is None
assert device.wifi_signal == -37
assert device.has_error is False
assert device.error_code is None
zones = device.zones
assert len(zones) == 2
assert zones[0].name == "Downstairs"
assert zones[0].zone_index == 1
assert zones[0].room_temperature is None
assert zones[0].target_temperature is None
assert zones[0].flow_temperature == 36.0
assert zones[0].return_temperature == 30.0
assert zones[0].target_flow_temperature is None
assert zones[0].operation_mode is None
assert zones[0].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
]
assert zones[0].status == ZONE_STATUS_UNKNOWN
assert zones[1].name == "Upstairs"
assert zones[1].zone_index == 2
assert zones[1].room_temperature is None
assert zones[1].target_temperature is None
assert zones[1].flow_temperature == 36.0
assert zones[1].return_temperature == 30.0
assert zones[1].target_flow_temperature is None
assert zones[1].operation_mode is None
assert zones[1].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
]
assert zones[1].status == ZONE_STATUS_UNKNOWN
await device.update()
assert device.operation_mode == OPERATION_MODE_AUTO
assert device.status == STATUS_HEAT_ZONES
assert device.tank_temperature == 49.5
assert device.target_tank_temperature == 50.0
assert device.flow_temperature_boiler == 25
assert device.return_temperature_boiler == 25
assert device.mixing_tank_temperature == 0
assert device.immersion_heater_enabled is True
assert device.holiday_mode is False
assert device.wifi_signal == -37
assert device.has_error is False
assert device.error_code == 8000
assert zones[0].room_temperature == 20.5
assert zones[0].target_temperature == 19.5
assert zones[0].target_flow_temperature == 25.0
assert zones[0].operation_mode == ZONE_OPERATION_MODE_HEAT_THERMOSTAT
assert zones[0].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
]
assert zones[0].status == ZONE_STATUS_HEAT
assert zones[1].room_temperature == 19.5
assert zones[1].target_temperature == 18
assert zones[1].target_flow_temperature == 25.0
assert zones[1].operation_mode == ZONE_OPERATION_MODE_HEAT_THERMOSTAT
assert zones[1].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
]
assert zones[1].status == ZONE_STATUS_HEAT
@pytest.mark.asyncio
async def test_2zone_cancool():
device = _build_device(
"atw_2zone_cancool_listdevice.json", "atw_2zone_cancool_get.json"
)
assert device.name == "Mitsubishi"
assert device.device_type == DEVICE_TYPE_ATW
assert device.temperature_increment == 0.5
assert device.operation_mode is None
assert device.operation_modes == [
OPERATION_MODE_AUTO,
OPERATION_MODE_FORCE_HOT_WATER,
]
assert device.tank_temperature is None
assert device.status is STATUS_UNKNOWN
assert device.target_tank_temperature is None
assert device.target_tank_temperature_min == 40
assert device.target_tank_temperature_max == 60
assert device.flow_temperature_boiler == 25
assert device.return_temperature_boiler == 25
assert device.mixing_tank_temperature is None
assert device.holiday_mode is None
assert device.wifi_signal == -82
assert device.has_error is False
assert device.error_code is None
zones = device.zones
assert len(zones) == 2
assert zones[0].name == "Zone 1"
assert zones[0].zone_index == 1
assert zones[0].room_temperature is None
assert zones[0].target_temperature is None
assert zones[0].flow_temperature == 50.5
assert zones[0].return_temperature == 50.5
assert zones[0].target_flow_temperature is None
assert zones[0].operation_mode is None
assert zones[0].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
ZONE_OPERATION_MODE_COOL_THERMOSTAT,
ZONE_OPERATION_MODE_COOL_FLOW,
]
assert zones[0].status == ZONE_STATUS_UNKNOWN
assert zones[1].name == "Zone 2"
assert zones[1].zone_index == 2
assert zones[1].room_temperature is None
assert zones[1].target_temperature is None
assert zones[1].flow_temperature == 50.5
assert zones[1].return_temperature == 50.5
assert zones[1].target_flow_temperature is None
assert zones[1].operation_mode is None
assert zones[1].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
ZONE_OPERATION_MODE_COOL_THERMOSTAT,
ZONE_OPERATION_MODE_COOL_FLOW,
]
assert zones[1].status == ZONE_STATUS_UNKNOWN
await device.update()
assert device.operation_mode == OPERATION_MODE_AUTO
assert device.status == STATUS_HEAT_WATER
assert device.tank_temperature == 47.5
assert device.target_tank_temperature == 52.0
assert device.flow_temperature_boiler == 25
assert device.return_temperature_boiler == 25
assert device.mixing_tank_temperature is None
assert device.holiday_mode is False
assert device.wifi_signal == -82
assert device.has_error is False
assert device.error_code == 8000
assert zones[0].room_temperature == 21.5
assert zones[0].target_temperature == 20.5
assert zones[0].target_flow_temperature == 5.0
assert zones[0].operation_mode == ZONE_OPERATION_MODE_CURVE
assert zones[0].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
ZONE_OPERATION_MODE_COOL_THERMOSTAT,
ZONE_OPERATION_MODE_COOL_FLOW,
]
assert zones[0].status == ZONE_STATUS_IDLE
assert zones[1].room_temperature == 21.0
assert zones[1].target_temperature == 21.0
assert zones[1].target_flow_temperature == 5.0
assert zones[1].operation_mode == ZONE_OPERATION_MODE_CURVE
assert zones[1].operation_modes == [
ZONE_OPERATION_MODE_HEAT_THERMOSTAT,
ZONE_OPERATION_MODE_HEAT_FLOW,
ZONE_OPERATION_MODE_CURVE,
ZONE_OPERATION_MODE_COOL_THERMOSTAT,
ZONE_OPERATION_MODE_COOL_FLOW,
]
assert zones[1].status == ZONE_STATUS_IDLE