I have EVCC running with load management enabled (using Homewizard P1 meter). My situation:
Symptom: EVCC thinks it needs to manage load and fully stops the car from charging.
[lp-1 ] DEBUG 2026/05/01 13:17:58 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:17:58 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:17:58 vehicle range: 126km
[lp-1 ] DEBUG 2026/05/01 13:17:58 soc estimated: 52.44% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:17:58 vehicle soc (estimator): 52%
[lp-1 ] DEBUG 2026/05/01 13:17:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:17:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:17:58 validate current: 18.8A + (18.7A -> 32A) > 25A capped at 24.9A
[lp-1 ] DEBUG 2026/05/01 13:17:58 set charge current limit: 24.9A
[site ] DEBUG 2026/05/01 13:17:58 solar forecast: accumulated 0.030Wh from 2026-05-01 13:17:28 +0200 CEST to 2026-05-01 13:17:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:17:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:17:58 solar forecast: accumulated 1255.565kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:18:28 ----
[lp-1 ] DEBUG 2026/05/01 13:18:28 charge power: 4126W
[lp-1 ] DEBUG 2026/05/01 13:18:28 charge currents: [18.7 0.036 0.033]A
[main ] DEBUG 2026/05/01 13:18:28 power: 6998W
[main ] DEBUG 2026/05/01 13:18:28 current: 17.9A
[site ] DEBUG 2026/05/01 13:18:28 grid power: 6998W
[site ] DEBUG 2026/05/01 13:18:28 grid currents: [17.9 0 12.6]A
[site ] DEBUG 2026/05/01 13:18:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:18:28 site power: 6998W
[lp-1 ] DEBUG 2026/05/01 13:18:28 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:18:28 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:18:28 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:18:28 vehicle range: 126km
[lp-1 ] DEBUG 2026/05/01 13:18:28 soc estimated: 52.44% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:18:28 vehicle soc (estimator): 52%
[lp-1 ] DEBUG 2026/05/01 13:18:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:18:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:18:28 validate current: 17.9A + (18.7A -> 32A) > 25A capped at 25.8A
[lp-1 ] DEBUG 2026/05/01 13:18:28 set charge current limit: 25.8A
[site ] DEBUG 2026/05/01 13:18:28 solar forecast: accumulated 0.030Wh from 2026-05-01 13:17:58 +0200 CEST to 2026-05-01 13:18:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:18:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:18:28 solar forecast: accumulated 1255.595kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:18:58 ----
[lp-1 ] DEBUG 2026/05/01 13:18:59 charge power: 4275W
[lp-1 ] DEBUG 2026/05/01 13:18:59 charge currents: [18.1 0.039 0.032]A
[main ] DEBUG 2026/05/01 13:18:59 power: 7045W
[main ] DEBUG 2026/05/01 13:18:59 current: 18.8A
[site ] DEBUG 2026/05/01 13:18:59 grid power: 7045W
[site ] DEBUG 2026/05/01 13:18:59 grid currents: [18.8 0 11.8]A
[site ] DEBUG 2026/05/01 13:18:59 pv power: 0W
[site ] DEBUG 2026/05/01 13:18:59 site power: 7045W
[lp-1 ] DEBUG 2026/05/01 13:18:59 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:18:59 session energy: 0.910kWh
[lp-1 ] DEBUG 2026/05/01 13:18:59 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:18:59 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:18:59 vehicle range: 126km
[lp-1 ] DEBUG 2026/05/01 13:18:59 soc estimated: 52.55% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:18:59 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:18:59 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:18:59 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:18:59 validate current: 18.8A + (18.1A -> 32A) > 25A capped at 24.2A
[lp-1 ] DEBUG 2026/05/01 13:18:59 set charge current limit: 24.2A
[site ] DEBUG 2026/05/01 13:18:59 solar forecast: accumulated 0.032Wh from 2026-05-01 13:18:28 +0200 CEST to 2026-05-01 13:18:59 +0200 CEST
[site ] DEBUG 2026/05/01 13:18:59 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:18:59 solar forecast: accumulated 1255.627kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:19:28 ----
[lp-1 ] DEBUG 2026/05/01 13:19:28 charge power: 4275W
[lp-1 ] DEBUG 2026/05/01 13:19:28 charge currents: [18.1 0.039 0.032]A
[main ] DEBUG 2026/05/01 13:19:28 power: 7180W
[main ] DEBUG 2026/05/01 13:19:28 current: 19.2A
[site ] DEBUG 2026/05/01 13:19:28 grid power: 7180W
[site ] DEBUG 2026/05/01 13:19:28 grid currents: [19.2 0 12.3]A
[site ] DEBUG 2026/05/01 13:19:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:19:28 site power: 7180W
[lp-1 ] DEBUG 2026/05/01 13:19:28 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:19:28 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:19:28 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:19:28 vehicle range: 126km
[lp-1 ] DEBUG 2026/05/01 13:19:28 soc estimated: 52.55% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:19:28 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:19:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:19:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:19:28 validate current: 19.2A + (18.1A -> 32A) > 25A capped at 23.8A
[lp-1 ] DEBUG 2026/05/01 13:19:28 set charge current limit: 23.8A
[site ] DEBUG 2026/05/01 13:19:28 solar forecast: accumulated 0.029Wh from 2026-05-01 13:18:59 +0200 CEST to 2026-05-01 13:19:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:19:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:19:28 solar forecast: accumulated 1255.656kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:19:58 ----
[lp-1 ] DEBUG 2026/05/01 13:19:58 charge power: 4275W
[lp-1 ] DEBUG 2026/05/01 13:19:58 charge currents: [18.1 0.039 0.032]A
[main ] DEBUG 2026/05/01 13:19:58 power: 7108W
[main ] DEBUG 2026/05/01 13:19:58 current: 19.1A
[site ] DEBUG 2026/05/01 13:19:58 grid power: 7108W
[site ] DEBUG 2026/05/01 13:19:58 grid currents: [19.1 0 12.1]A
[site ] DEBUG 2026/05/01 13:19:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:19:58 site power: 7108W
[lp-1 ] DEBUG 2026/05/01 13:19:58 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:19:58 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:19:58 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:19:58 vehicle range: 126km
[lp-1 ] DEBUG 2026/05/01 13:19:58 soc estimated: 52.55% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:19:58 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:19:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:19:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:19:58 validate current: 19.1A + (18.1A -> 32A) > 25A capped at 24A
[lp-1 ] DEBUG 2026/05/01 13:19:58 set charge current limit: 24A
[site ] DEBUG 2026/05/01 13:19:58 solar forecast: accumulated 0.030Wh from 2026-05-01 13:19:28 +0200 CEST to 2026-05-01 13:19:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:19:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:19:58 solar forecast: accumulated 1255.687kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:20:28 ----
[lp-1 ] DEBUG 2026/05/01 13:20:28 charge power: 4275W
[lp-1 ] DEBUG 2026/05/01 13:20:28 charge currents: [18.1 0.039 0.032]A
[main ] DEBUG 2026/05/01 13:20:28 power: 9044W
[main ] DEBUG 2026/05/01 13:20:28 current: 20.7A
[site ] DEBUG 2026/05/01 13:20:28 grid power: 9044W
[site ] DEBUG 2026/05/01 13:20:28 grid currents: [19 0 20.7]A
[site ] DEBUG 2026/05/01 13:20:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:20:28 site power: 9044W
[lp-1 ] DEBUG 2026/05/01 13:20:28 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:20:28 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:20:28 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:20:28 vehicle range: 126km
[lp-1 ] DEBUG 2026/05/01 13:20:28 soc estimated: 52.55% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:20:28 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:20:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:20:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:20:28 validate current: 20.7A + (18.1A -> 32A) > 25A capped at 22.4A
[lp-1 ] DEBUG 2026/05/01 13:20:28 set charge current limit: 22.4A
[site ] DEBUG 2026/05/01 13:20:28 solar forecast: accumulated 0.030Wh from 2026-05-01 13:19:58 +0200 CEST to 2026-05-01 13:20:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:20:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:20:28 solar forecast: accumulated 1255.717kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:20:58 ----
[lp-1 ] DEBUG 2026/05/01 13:20:58 charge power: 4457W
[lp-1 ] DEBUG 2026/05/01 13:20:58 charge currents: [19.6 0.045 0.027]A
[main ] DEBUG 2026/05/01 13:20:58 power: 8951W
[main ] DEBUG 2026/05/01 13:20:58 current: 20.6A
[site ] DEBUG 2026/05/01 13:20:58 grid power: 8951W
[site ] DEBUG 2026/05/01 13:20:58 grid currents: [18.6 0 20.6]A
[site ] DEBUG 2026/05/01 13:20:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:20:58 site power: 8951W
[lp-1 ] DEBUG 2026/05/01 13:20:58 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:20:58 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:20:58 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:20:58 vehicle range: 126km
[lp-1 ] DEBUG 2026/05/01 13:20:58 soc estimated: 52.55% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:20:58 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:20:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:20:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:20:58 validate current: 20.6A + (19.6A -> 32A) > 25A capped at 24A
[lp-1 ] DEBUG 2026/05/01 13:20:58 set charge current limit: 24A
[site ] DEBUG 2026/05/01 13:20:58 solar forecast: accumulated 0.030Wh from 2026-05-01 13:20:28 +0200 CEST to 2026-05-01 13:20:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:20:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:20:58 solar forecast: accumulated 1255.747kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:21:28 ----
[lp-1 ] DEBUG 2026/05/01 13:21:28 charge power: 4198W
[lp-1 ] DEBUG 2026/05/01 13:21:28 charge currents: [19.4 0.03 0.033]A
[main ] DEBUG 2026/05/01 13:21:28 power: 9260W
[main ] DEBUG 2026/05/01 13:21:28 current: 21.3A
[site ] DEBUG 2026/05/01 13:21:28 grid power: 9260W
[site ] DEBUG 2026/05/01 13:21:28 grid currents: [19.5 0 21.3]A
[site ] DEBUG 2026/05/01 13:21:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:21:28 site power: 9260W
[lp-1 ] DEBUG 2026/05/01 13:21:28 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:21:28 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:21:30 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:21:30 vehicle range: 128km
[lp-1 ] DEBUG 2026/05/01 13:21:30 soc estimated: 52.55% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:21:30 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:21:30 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:21:30 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:21:30 validate current: 21.3A + (19.4A -> 32A) > 25A capped at 23.2A
[lp-1 ] DEBUG 2026/05/01 13:21:30 set charge current limit: 23.2A
[site ] DEBUG 2026/05/01 13:21:30 solar forecast: accumulated 0.033Wh from 2026-05-01 13:20:58 +0200 CEST to 2026-05-01 13:21:30 +0200 CEST
[site ] DEBUG 2026/05/01 13:21:30 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:21:30 solar forecast: accumulated 1255.780kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:21:58 ----
[lp-1 ] DEBUG 2026/05/01 13:21:58 charge power: 4198W
[lp-1 ] DEBUG 2026/05/01 13:21:58 charge currents: [19.4 0.03 0.033]A
[main ] DEBUG 2026/05/01 13:21:58 power: 9291W
[main ] DEBUG 2026/05/01 13:21:58 current: 21.4A
[site ] DEBUG 2026/05/01 13:21:58 grid power: 9291W
[site ] DEBUG 2026/05/01 13:21:58 grid currents: [19.6 0 21.4]A
[site ] DEBUG 2026/05/01 13:21:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:21:58 site power: 9291W
[lp-1 ] DEBUG 2026/05/01 13:21:58 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:21:58 session energy: 1.112kWh
[lp-1 ] DEBUG 2026/05/01 13:21:58 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:21:58 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:21:58 vehicle range: 128km
[lp-1 ] DEBUG 2026/05/01 13:21:58 soc estimated: 52.89% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:21:58 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:21:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:21:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:21:58 validate current: 21.4A + (19.4A -> 32A) > 25A capped at 23.1A
[lp-1 ] DEBUG 2026/05/01 13:21:58 set charge current limit: 23.1A
[site ] DEBUG 2026/05/01 13:21:58 solar forecast: accumulated 0.028Wh from 2026-05-01 13:21:30 +0200 CEST to 2026-05-01 13:21:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:21:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:21:58 solar forecast: accumulated 1255.808kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:22:28 ----
[lp-1 ] DEBUG 2026/05/01 13:22:28 charge power: 4515W
[lp-1 ] DEBUG 2026/05/01 13:22:28 charge currents: [19.9 0.037 0.033]A
[main ] DEBUG 2026/05/01 13:22:28 power: 8980W
[main ] DEBUG 2026/05/01 13:22:28 current: 20.9A
[site ] DEBUG 2026/05/01 13:22:28 grid power: 8980W
[site ] DEBUG 2026/05/01 13:22:28 grid currents: [18.8 0 20.9]A
[site ] DEBUG 2026/05/01 13:22:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:22:28 site power: 8980W
[lp-1 ] DEBUG 2026/05/01 13:22:28 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:22:28 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:22:28 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:22:28 vehicle range: 128km
[lp-1 ] DEBUG 2026/05/01 13:22:28 soc estimated: 52.89% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:22:28 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:22:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:22:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:22:28 validate current: 20.9A + (19.9A -> 32A) > 25A capped at 24A
[lp-1 ] DEBUG 2026/05/01 13:22:28 set charge current limit: 24A
[site ] DEBUG 2026/05/01 13:22:28 solar forecast: accumulated 0.030Wh from 2026-05-01 13:21:58 +0200 CEST to 2026-05-01 13:22:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:22:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:22:28 solar forecast: accumulated 1255.839kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:22:58 ----
[lp-1 ] DEBUG 2026/05/01 13:22:58 charge power: 4602W
[lp-1 ] DEBUG 2026/05/01 13:22:58 charge currents: [19.9 0.039 0.038]A
[main ] DEBUG 2026/05/01 13:22:58 power: 10812W
[main ] WARN 2026/05/01 13:22:58 over current detected: 30A > 25A
[site ] DEBUG 2026/05/01 13:22:58 grid power: 10812W
[site ] DEBUG 2026/05/01 13:22:58 grid currents: [18 0 30]A
[site ] DEBUG 2026/05/01 13:22:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:22:58 site power: 10812W
[lp-1 ] DEBUG 2026/05/01 13:22:58 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:22:58 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:22:58 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:22:58 vehicle range: 128km
[lp-1 ] DEBUG 2026/05/01 13:22:58 soc estimated: 52.89% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:22:58 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:22:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:22:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:22:58 validate current: 30A + (19.9A -> 32A) > 25A capped at 14.9A
[lp-1 ] DEBUG 2026/05/01 13:22:58 set charge current limit: 14.9A
[site ] DEBUG 2026/05/01 13:22:58 solar forecast: accumulated 0.030Wh from 2026-05-01 13:22:28 +0200 CEST to 2026-05-01 13:22:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:22:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:22:58 solar forecast: accumulated 1255.869kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:23:28 ----
[lp-1 ] DEBUG 2026/05/01 13:23:28 charge power: 3113W
[lp-1 ] DEBUG 2026/05/01 13:23:28 charge currents: [14.1 0.025 0.027]A
[main ] DEBUG 2026/05/01 13:23:28 power: 9211W
[main ] WARN 2026/05/01 13:23:28 over current detected: 27.9A > 25A
[site ] DEBUG 2026/05/01 13:23:28 grid power: 9211W
[site ] DEBUG 2026/05/01 13:23:28 grid currents: [12.7 0 27.9]A
[site ] DEBUG 2026/05/01 13:23:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:23:28 site power: 9211W
[lp-1 ] DEBUG 2026/05/01 13:23:28 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:23:28 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:23:28 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:23:28 vehicle range: 128km
[lp-1 ] DEBUG 2026/05/01 13:23:28 soc estimated: 52.89% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:23:28 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:23:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:23:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:23:28 validate current: 27.9A + (14.1A -> 32A) > 25A capped at 11.2A
[lp-1 ] DEBUG 2026/05/01 13:23:28 set charge current limit: 11.2A
[site ] DEBUG 2026/05/01 13:23:28 solar forecast: accumulated 0.030Wh from 2026-05-01 13:22:58 +0200 CEST to 2026-05-01 13:23:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:23:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:23:28 solar forecast: accumulated 1255.900kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:23:58 ----
[lp-1 ] DEBUG 2026/05/01 13:23:58 charge power: 2403W
[lp-1 ] DEBUG 2026/05/01 13:23:58 charge currents: [10.5 0.048 0.034]A
[main ] DEBUG 2026/05/01 13:23:58 power: 8685W
[main ] WARN 2026/05/01 13:23:58 over current detected: 27.7A > 25A
[site ] DEBUG 2026/05/01 13:23:58 grid power: 8685W
[site ] DEBUG 2026/05/01 13:23:58 grid currents: [10.9 0 27.7]A
[site ] DEBUG 2026/05/01 13:23:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:23:58 site power: 8685W
[lp-1 ] DEBUG 2026/05/01 13:23:58 detected active phases: 1p
[lp-1 ] DEBUG 2026/05/01 13:23:58 charger status: C
[lp-1 ] DEBUG 2026/05/01 13:23:58 vehicle soc: 51%
[lp-1 ] DEBUG 2026/05/01 13:23:58 vehicle range: 128km
[lp-1 ] DEBUG 2026/05/01 13:23:58 soc estimated: 52.89% (vehicle: 51.00%)
[lp-1 ] DEBUG 2026/05/01 13:23:58 vehicle soc (estimator): 53%
[lp-1 ] DEBUG 2026/05/01 13:23:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:23:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:23:58 validate current: 27.7A + (10.5A -> 32A) > 25A capped at 7.89A
[lp-1 ] DEBUG 2026/05/01 13:23:58 charger disable
[site ] DEBUG 2026/05/01 13:23:58 solar forecast: accumulated 0.031Wh from 2026-05-01 13:23:28 +0200 CEST to 2026-05-01 13:23:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:23:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:23:58 solar forecast: accumulated 1255.930kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:24:28 ----
[lp-1 ] DEBUG 2026/05/01 13:24:28 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:24:28 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:24:28 power: 6203W
[main ] WARN 2026/05/01 13:24:28 over current detected: 27.8A > 25A
[site ] DEBUG 2026/05/01 13:24:28 grid power: 6203W
[site ] DEBUG 2026/05/01 13:24:28 grid currents: [0.013 0 27.8]A
[site ] DEBUG 2026/05/01 13:24:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:24:28 site power: 6203W
[lp-1 ] DEBUG 2026/05/01 13:24:28 session energy: 1.260kWh
[lp-1 ] DEBUG 2026/05/01 13:24:28 charger status: B
[lp-1 ] INFO 2026/05/01 13:24:28 stop charging <-
[lp-1 ] DEBUG 2026/05/01 13:24:30 vehicle soc: 56%
[lp-1 ] DEBUG 2026/05/01 13:24:30 vehicle range: 138km
[lp-1 ] DEBUG 2026/05/01 13:24:30 vehicle soc (estimator): 56%
[lp-1 ] DEBUG 2026/05/01 13:24:30 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:24:30 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:24:30 validate current: 27.8A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:24:30 solar forecast: accumulated 0.032Wh from 2026-05-01 13:23:58 +0200 CEST to 2026-05-01 13:24:30 +0200 CEST
[site ] DEBUG 2026/05/01 13:24:30 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:24:30 solar forecast: accumulated 1255.963kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:24:58 ----
[lp-1 ] DEBUG 2026/05/01 13:24:58 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:24:58 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:24:58 power: 6241W
[main ] WARN 2026/05/01 13:24:58 over current detected: 28.1A > 25A
[site ] DEBUG 2026/05/01 13:24:58 grid power: 6241W
[site ] DEBUG 2026/05/01 13:24:58 grid currents: [0.013 0 28.1]A
[site ] DEBUG 2026/05/01 13:24:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:24:58 site power: 6241W
[lp-1 ] DEBUG 2026/05/01 13:24:58 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:24:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:24:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:24:58 validate current: 28.1A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:24:58 solar forecast: accumulated 0.028Wh from 2026-05-01 13:24:30 +0200 CEST to 2026-05-01 13:24:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:24:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:24:58 solar forecast: accumulated 1255.991kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:25:28 ----
[lp-1 ] DEBUG 2026/05/01 13:25:28 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:25:28 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:25:28 power: 6168W
[main ] WARN 2026/05/01 13:25:28 over current detected: 27.7A > 25A
[site ] DEBUG 2026/05/01 13:25:28 grid power: 6168W
[site ] DEBUG 2026/05/01 13:25:28 grid currents: [0.013 0 27.7]A
[site ] DEBUG 2026/05/01 13:25:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:25:28 site power: 6168W
[lp-1 ] DEBUG 2026/05/01 13:25:28 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:25:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:25:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:25:28 validate current: 27.7A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:25:28 solar forecast: accumulated 0.030Wh from 2026-05-01 13:24:58 +0200 CEST to 2026-05-01 13:25:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:25:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:25:28 solar forecast: accumulated 1256.021kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:25:58 ----
[lp-1 ] DEBUG 2026/05/01 13:25:58 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:25:58 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:25:58 power: 6119W
[main ] WARN 2026/05/01 13:25:58 over current detected: 27.4A > 25A
[site ] DEBUG 2026/05/01 13:25:58 grid power: 6119W
[site ] DEBUG 2026/05/01 13:25:58 grid currents: [0.013 0 27.4]A
[site ] DEBUG 2026/05/01 13:25:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:25:58 site power: 6119W
[lp-1 ] DEBUG 2026/05/01 13:25:58 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:25:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:25:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:25:58 validate current: 27.4A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:25:58 solar forecast: accumulated 0.030Wh from 2026-05-01 13:25:28 +0200 CEST to 2026-05-01 13:25:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:25:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:25:58 solar forecast: accumulated 1256.052kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:26:28 ----
[lp-1 ] DEBUG 2026/05/01 13:26:28 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:26:28 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:26:28 power: 5717W
[main ] WARN 2026/05/01 13:26:28 over current detected: 25.5A > 25A
[site ] DEBUG 2026/05/01 13:26:28 grid power: 5717W
[site ] DEBUG 2026/05/01 13:26:28 grid currents: [0.013 0 25.5]A
[site ] DEBUG 2026/05/01 13:26:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:26:28 site power: 5717W
[lp-1 ] DEBUG 2026/05/01 13:26:28 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:26:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:26:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:26:28 validate current: 25.5A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:26:28 solar forecast: accumulated 0.030Wh from 2026-05-01 13:25:58 +0200 CEST to 2026-05-01 13:26:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:26:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:26:28 solar forecast: accumulated 1256.082kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:26:58 ----
[lp-1 ] DEBUG 2026/05/01 13:26:58 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:26:58 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:26:58 power: 5737W
[main ] WARN 2026/05/01 13:26:58 over current detected: 25.7A > 25A
[site ] DEBUG 2026/05/01 13:26:58 grid power: 5737W
[site ] DEBUG 2026/05/01 13:26:58 grid currents: [0.013 0 25.7]A
[site ] DEBUG 2026/05/01 13:26:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:26:58 site power: 5737W
[lp-1 ] DEBUG 2026/05/01 13:26:58 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:26:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:26:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:26:58 validate current: 25.7A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:26:58 solar forecast: accumulated 0.030Wh from 2026-05-01 13:26:28 +0200 CEST to 2026-05-01 13:26:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:26:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:26:58 solar forecast: accumulated 1256.113kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:27:28 ----
[lp-1 ] DEBUG 2026/05/01 13:27:28 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:27:28 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:27:28 power: 5697W
[main ] WARN 2026/05/01 13:27:28 over current detected: 25.3A > 25A
[site ] DEBUG 2026/05/01 13:27:28 grid power: 5697W
[site ] DEBUG 2026/05/01 13:27:28 grid currents: [0.013 0 25.3]A
[site ] DEBUG 2026/05/01 13:27:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:27:28 site power: 5697W
[lp-1 ] DEBUG 2026/05/01 13:27:28 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:27:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:27:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:27:28 validate current: 25.3A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:27:28 solar forecast: accumulated 0.030Wh from 2026-05-01 13:26:58 +0200 CEST to 2026-05-01 13:27:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:27:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:27:28 solar forecast: accumulated 1256.143kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:27:58 ----
[lp-1 ] DEBUG 2026/05/01 13:27:58 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:27:58 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:27:58 power: 5855W
[main ] WARN 2026/05/01 13:27:58 over current detected: 26.1A > 25A
[site ] DEBUG 2026/05/01 13:27:58 grid power: 5855W
[site ] DEBUG 2026/05/01 13:27:58 grid currents: [0.013 0 26.1]A
[site ] DEBUG 2026/05/01 13:27:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:27:58 site power: 5855W
[lp-1 ] DEBUG 2026/05/01 13:27:58 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:27:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:27:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:27:58 validate current: 26.1A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:27:58 solar forecast: accumulated 0.030Wh from 2026-05-01 13:27:28 +0200 CEST to 2026-05-01 13:27:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:27:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:27:58 solar forecast: accumulated 1256.174kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:28:28 ----
[lp-1 ] DEBUG 2026/05/01 13:28:28 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:28:28 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:28:28 power: 5749W
[main ] WARN 2026/05/01 13:28:28 over current detected: 25.8A > 25A
[site ] DEBUG 2026/05/01 13:28:28 grid power: 5749W
[site ] DEBUG 2026/05/01 13:28:28 grid currents: [0.013 0 25.8]A
[site ] DEBUG 2026/05/01 13:28:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:28:28 site power: 5749W
[lp-1 ] DEBUG 2026/05/01 13:28:28 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:28:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:28:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:28:28 validate current: 25.8A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:28:28 solar forecast: accumulated 0.030Wh from 2026-05-01 13:27:58 +0200 CEST to 2026-05-01 13:28:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:28:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:28:28 solar forecast: accumulated 1256.204kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:28:58 ----
[lp-1 ] DEBUG 2026/05/01 13:28:58 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:28:58 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:28:58 power: 5736W
[main ] WARN 2026/05/01 13:28:58 over current detected: 25.7A > 25A
[site ] DEBUG 2026/05/01 13:28:58 grid power: 5736W
[site ] DEBUG 2026/05/01 13:28:58 grid currents: [0.013 0 25.7]A
[site ] DEBUG 2026/05/01 13:28:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:28:58 site power: 5736W
[lp-1 ] DEBUG 2026/05/01 13:28:58 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:28:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:28:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:28:58 validate current: 25.7A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:28:58 solar forecast: accumulated 0.030Wh from 2026-05-01 13:28:28 +0200 CEST to 2026-05-01 13:28:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:28:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:28:58 solar forecast: accumulated 1256.235kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:29:28 ----
[lp-1 ] DEBUG 2026/05/01 13:29:28 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:29:28 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:29:28 power: 5795W
[main ] WARN 2026/05/01 13:29:28 over current detected: 25.9A > 25A
[site ] DEBUG 2026/05/01 13:29:28 grid power: 5795W
[site ] DEBUG 2026/05/01 13:29:28 grid currents: [0.013 0 25.9]A
[site ] DEBUG 2026/05/01 13:29:28 pv power: 0W
[site ] DEBUG 2026/05/01 13:29:28 site power: 5795W
[lp-1 ] DEBUG 2026/05/01 13:29:28 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:29:28 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:29:28 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:29:28 validate current: 25.9A + (0.024A -> 32A) > 25A capped at 0A
[site ] DEBUG 2026/05/01 13:29:28 solar forecast: accumulated 0.030Wh from 2026-05-01 13:28:58 +0200 CEST to 2026-05-01 13:29:28 +0200 CEST
[site ] DEBUG 2026/05/01 13:29:28 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:29:28 solar forecast: accumulated 1256.265kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:29:58 ----
[lp-1 ] DEBUG 2026/05/01 13:29:58 charge power: 0W
[lp-1 ] DEBUG 2026/05/01 13:29:58 charge currents: [0.023 0.023 0.024]A
[main ] DEBUG 2026/05/01 13:29:58 power: 3786W
[main ] DEBUG 2026/05/01 13:29:58 current: 16.9A
[site ] DEBUG 2026/05/01 13:29:58 grid power: 3786W
[site ] DEBUG 2026/05/01 13:29:58 grid currents: [0.013 0 16.9]A
[site ] DEBUG 2026/05/01 13:29:58 pv power: 0W
[site ] DEBUG 2026/05/01 13:29:58 site power: 3786W
[lp-1 ] DEBUG 2026/05/01 13:29:58 charger status: B
[lp-1 ] DEBUG 2026/05/01 13:29:58 !! plan: plan time zero
[lp-1 ] DEBUG 2026/05/01 13:29:58 smart consumption active: -0.47
[main ] DEBUG 2026/05/01 13:29:58 validate current: 16.9A + (0.024A -> 32A) > 25A capped at 8.14A
[site ] DEBUG 2026/05/01 13:29:58 solar forecast: accumulated 0.030Wh from 2026-05-01 13:29:28 +0200 CEST to 2026-05-01 13:29:58 +0200 CEST
[site ] DEBUG 2026/05/01 13:29:58 solar forecast: produced 0.000
[site ] DEBUG 2026/05/01 13:29:58 solar forecast: accumulated 1256.295kWh, produced 0.000kWh, scale 0.000
[site ] DEBUG 2026/05/01 13:30:28 ----
Describe the bug
I have EVCC running with load management enabled (using Homewizard P1 meter). My situation:
Symptom: EVCC thinks it needs to manage load and fully stops the car from charging.
Steps to reproduce
Configuration details
Log details
What type of operating system or environment does evcc run on?
Docker container
External automation
Nightly build
Version
0.305.1