This describes the Z-Wave device ZIR010, manufactured by ACT - Advanced Control Technologies with the thing type UID of act_zir010_00_000
.
The device is in the category of Motion Detector, defining Motion sensors/detectors.
The ZIR010 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZIR010 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The ZIR010 Wall Mounted Sensor is a component of the HomePro lighting control system. Inclusion of this Wall Mounted Sensor on the ZTH200 Wireless Controller menu allows remote turn-on of HomePro receivers and their connected lighting when the ZIR010 is triggered. Z-Wave nodes of other types can be added to the system and will also act as repeaters if they support this function of repeating the signal received to other modules in the system.
ZIR010 must be installed in its permanent location. To include or exclude the ZIR010 from the Z-Wave network, press the brown button marked “button” (inside) when prompted by a Z-Wave controller. For ZIR010 to work properly over longer distances (i.e. communicate via more nodes), add it to the network after you have added all other non-battery operated devices. Now replace the cover and screw. The ZIR010 will stay “awake” for ten minutes when power is first applied to allow time for configuration.
To exclude the ZIR010 from the Z-Wave network, press the brown button marked “button” (inside) when prompted by a Z-Wave controller.
The ZIR010 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZIR010 will send a Wakeup Notification Command approximately 3 minutes after power up IF and only IF it has been included into a Z-Wave network. From that point on, the ZIR010 will wake up every 4 hours and re-send the Wakeup Notification Command unless configured for another time interval. The ZIR010 will stay awake by default for 30 seconds and then go back to sleep to conserve battery life.
The time interval between Wakeup Notification Commands can be adjusted if you have a device that supports this. Refer to that device’s instructions.
The time the ZIR010 stays awake can be adjusted from 15 seconds to 45 seconds by sending a value of 15 to 45 to the ZIR010 using Configuration Parameter # 22 (when asked for the number of bytes, select 1). This awake time period starts over every time the ZIR010 receives a command or request.
The following table summarises the channels available for the ZIR010 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Binary Sensor | sensor_binary | Door | Switch |
Alarm | alarm_general | Door | Switch |
Battery Level | battery-level | Battery | Number |
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 4 configuration parameters available in the ZIR010. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
17 | Mode | Notification modes: 0=light, 1=alarm, 2=sensor |
18 | Off/Idle delay | Configuring the off/idle delay |
19 | Unsolicited Commands | Disabling the zir010 trom sending commands unsolicited |
22 | Awake Time | Duration ranges from 15 to 45 seconds. Valid values range from 15 to 45. |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Notification modes: 0=light, 1=alarm, 2=sensor The ZIR010 can be configured to operate in 1 of 3 modes. Those modes are:
• Lighting Mode (factory default)
• Alarm Mode
• Sensor Mode
To change the mode of operation:
For Lighting Mode: Send a value of 0 to Configuration Parameter #17.
For Alarm Mode: Send a value of 1 to Configuration Parameter #17.
For Sensor Mode: Send a value of 2 to Configuration Parameter # 17.
The following option values may be configured -:
Value | Description |
---|---|
0 | Lightning |
1 | Alarm |
2 | Sensor |
The manufacturer defined default value is 0
(Lightning).
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Configuring the off/idle delay OFF/IDLE (Applicable only when the ZIR010 is configured for Lighting or Binary Sensor Mode).
The ZIR010 will consider there to be “No Activity” after 2 minutes passes during which the ZIR010 detected no motion. At that point, the ZIR010 can be configured to immediately send the OFF or IDLE command or it can be configured to send it from 1 minute to 255 minutes later. (+/- 1 minute). Values in the range 0 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Disabling the zir010 trom sending commands unsolicited The ZIR010 can be disabled from sending commands unsolicited without removing associated devices by setting Configuration Parameter # 19 to 0 (when asked for number of bytes, select 1). Setting it back to 1 will re-enable the ZIR010. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(enabled).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Duration ranges from 15 to 45 seconds. Valid values range from 15 to 45. The ZIR010 will send a Wakeup Notification Command approximately 3 minutes after power up IF and only IF it has been included into a Z-Wave network. From that point on, the ZIR010 will wake up every 4 hours and re-send the Wakeup Notification Command unless configured for another time interval. The ZIR010 will stay awake by default for 30 seconds and then go back to sleep to conserve battery life.
The time interval between Wakeup Notification Commands can be adjusted if you have a device that supports this. Refer to that device’s instructions.
The time the ZIR010 stays awake can be adjusted from 15 seconds to 45 seconds by sending a value of 15 to 45 to the ZIR010 using Configuration Parameter # 22 (when asked for the number of bytes, select 1). This awake time period starts over every time the ZIR010 receives a command or request. Values in the range 15 to 45 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZIR010 supports 3 association groups.
If the ZIR010 is configured to operate in Lighting Mode, any device that is associated into Group 1 will be sent ON and OFF commands. See OFF/IDLE command section below for how to configure the length of a delay before an OFF command is sent*.
If the ZIR010 is configured to operate in Alarm Mode, any device that is associated into Group 1 will be sent an ALARM command when the ZIR010 detects motion.
If the ZIR010 is configured to operate in Binary Sensor Mode, any device that is associated into Group 1 will be sent an update whenever the ZIR010 detects motion or stops detecting motion.
- See OFF/IDLE command section below to configure the length of a delay before an OFF command is sent.
Association group 1 supports 5 nodes.
If the ZIR010 is configured to operate in Lighting Mode, any device that is associated into Group 2 will be sent ON commands when the housing of the ZIR010 is opened.
If the ZIR010 is configured to operating in Alarm Mode, any device that is associated into Group 2 will be sent an Alarm command when the housing of the ZIR010 is opened.
If the ZIR010 is configured to operate in Binary Sensor Mode, any device that is associated into Group 2 will be sent an update when the housing of the ZIR010 is opened.
Association group 2 supports 5 nodes.
Any device that is associated into Group 3 will be sent battery level indications at specific intervals. There can be up to 5 devices associated into each group.
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.