This describes the Z-Wave device DSB09, manufactured by AEON Labs with the thing type UID of aeon_dsb09_00_000
.
The device is in the category of Sensor, defining Device used to measure something.
The DSB09 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Your Home Energy Meter can be reset to default factory settings with ease.
- Press and hold the Action Button for 10 seconds.
- If successful, the LED on the HEM should begin to blink slowly.
The electrical installation of your Home Energy Meter (HEM) is now complete. You must now wirelessly link it to your Z-Wave network.
- Put your primary Z-Wave controller, usually a gateway or hub, into inclusion mode. If you are not sure how to do this, please refer to your controller’s user manual.
- Press the Action Button on your HEM. If it has been successfully linked to your network, its LED will remain illuminated. If the linking was unsuccessful, your HEM’s LED will continue to blink.
Your Home Energy Meter (HEM) can be removed from your Z-Wave network at any time. You'll need to use your Z-Wave network’s primary to do this.
- Put your main controller into its device removal mode. If you are unsure how to do this, please refer to your controller’s user manual.
- Press the Action Button on your HEM. If it has been successfully removed from your network, its LED will blink. If the removal was unsuccessful, its LED will be solid and it will be then repeated again.
NOTE: If a report is included in more then one Report Group, it will only be sent in the Report Group with the most recently updated configuration parameter.
The following table summarises the channels available for the DSB09 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Sensor (power) | sensor_power | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
Reset Meter | meter_reset | Energy | Switch |
Battery Level | battery-level | Battery | Number |
Sensor (power) 1 | sensor_power1 | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | Energy | Number |
Electric meter (watts) 1 | meter_watts1 | Energy | Number |
Sensor (power) 2 | sensor_power2 | Energy | Number |
Electric meter (kWh) 2 | meter_kwh2 | Energy | Number |
Electric meter (watts) 2 | meter_watts2 | Energy | Number |
Sensor (power) 3 | sensor_power3 | Energy | Number |
Electric meter (kWh) 3 | meter_kwh3 | Energy | Number |
Electric meter (watts) 3 | meter_watts3 | Energy | Number |
Indicates the energy consumption (kWh).
The sensor_power
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel supports the Switch
item and is in the Energy
category.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Indicates the energy consumption (kWh).
The sensor_power1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The sensor_power2
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh2
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts2
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The sensor_power3
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh3
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts3
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 49 configuration parameters available in the DSB09. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Voltage | Voltage to calculate wattage from amperage. |
3 | Selective Reporting: Whole HEM | |
3 | Selective Reporting: Clamp 1 | |
3 | Selective Reporting: Clamp 2 | |
3 | Selective Reporting: Clamp 3 | |
4 | Current Threshold - Whole HEM | Threshold change in wattage to induce an automatic report (Whole HEM). |
5 | Current Threshold - Clamp 1 | Threshold change in wattage to induce an automatic report (Clamp 1) |
6 | Current Threshold - Clamp 2 | Threshold change in wattage to induce an automatic report (Clamp 2) |
7 | Current Threshold - Clamp 3 | Threshold change in wattage to induce an automatic report (Clamp 3) |
8 | Percent Change - Whole HEM | Percentage change in wattage to induce an automatic report (Whole HEM) |
9 | Percent Change - Clamp 1 | Percentage change in wattage to induce an automatic report (Clamp 1) |
10 | Percent Change - Clamp 2 | Percentage change in wattage to induce an automatic report (Clamp 2) |
11 | Percent Change - Clamp 3 | Percentage change in wattage to induce an automatic report (Clamp 3) |
100 | Set parameters 101-103 to default values | |
101 | Report Group 1: Battery Report | |
101 | Report Group 1: MultiSensor Report for Watt (whole HEM) | |
101 | Report Group 1: Meter Report for Watt (whole device) | |
101 | Report Group 1: Meter Report for kWh (whole HEM) | |
101 | Report Group 1: Meter Report for Watt (clamp 1) | |
101 | Report Group 1: Meter Report for Watt (clamp 2) | |
101 | Report Group 1: Meter Report for Watt (clamp 3) | |
101 | Report Group 1: Meter Report for kWh (clamp 1) | |
101 | Report Group 1: Meter Report for kWh (clamp 2) | |
101 | Report Group 1: Meter Report for kWh (clamp 3) | |
102 | Report Group 2: Battery Report | |
102 | Report Group 2: MultiSensor Report for Watt (whole HEM) | |
102 | Report Group 2: Meter Report for Watt (whole device) | |
102 | Report Group 2: Meter Report for kWh (whole HEM) | |
102 | Report Group 2: Meter Report for Watt (clamp 1) | |
102 | Report Group 2: Meter Report for Watt (clamp 2) | |
102 | Report Group 2: Meter Report for Watt (clamp 3) | |
102 | Report Group 2: Meter Report for kWh (clamp 1) | |
102 | Report Group 2: Meter Report for kWh (clamp 2) | |
102 | Report Group 2: Meter Report for kWh (clamp 3) | |
103 | Report Group 3: Battery Report | |
103 | Report Group 3: MultiSensor Report for Watt (whole HEM) | |
103 | Report Group 3: Meter Report for Watt (whole device) | |
103 | Report Group 3: Meter Report for kWh (whole HEM) | |
103 | Report Group 3: Meter Report for Watt (clamp 1) | |
103 | Report Group 3: Meter Report for Watt (clamp 2) | |
103 | Report Group 3: Meter Report for Watt (clamp 3) | |
103 | Report Group 3: Meter Report for kWh (clamp 1) | |
103 | Report Group 3: Meter Report for kWh (clamp 2) | |
103 | Report Group 3: Meter Report for kWh (clamp 3) | |
110 | Set parameters 111-113 to default values | |
111 | Interval to send Report Group 1 | |
112 | Interval to send Report Group 2 | |
113 | Interval to send Report Group 3 | |
255 | Reset to Factory | Reset all settings to factory defaults |
Voltage to calculate wattage from amperage.
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 240
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_3_1_00000001
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_3_1_00000002
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_3_1_00000004
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_3_1_00000008
and is of type INTEGER
.
Threshold change in wattage to induce an automatic report (Whole HEM). Valid values: 0-60,000 Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Threshold change in wattage to induce an automatic report (Clamp 1) Valid values: 0-60,000 Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
Threshold change in wattage to induce an automatic report (Clamp 2) Valid values: 0-60,000 Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
Threshold change in wattage to induce an automatic report (Clamp 3) Valid values: 0-60,000 Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_7_2
and is of type INTEGER
.
Percentage change in wattage to induce an automatic report (Whole HEM) Valid values: 0-100 Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Percentage change in wattage to induce an automatic report (Clamp 1) Valid values: 0-100 Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Percentage change in wattage to induce an automatic report (Clamp 2) Valid values: 0-100 Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Percentage change in wattage to induce an automatic report (Clamp 3) Valid values: 0-100 Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | No change |
1 | Reset |
The manufacturer defined default value is 0
(No change).
This parameter has the configuration ID config_100_4_wo
and is of type INTEGER
.
This is a write only parameter.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00000001
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00000002
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00000004
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00000008
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00000100
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00000200
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00000400
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00000800
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00001000
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_101_4_00002000
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00000001
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00000002
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00000004
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00000008
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00000100
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00000200
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00000400
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00000800
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00001000
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_102_4_00002000
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00000001
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00000002
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00000004
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00000008
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00000100
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00000200
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00000400
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00000800
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00001000
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_103_4_00002000
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | No change |
1 | Reset |
The manufacturer defined default value is 0
(No change).
This parameter has the configuration ID config_110_4_wo
and is of type INTEGER
.
This is a write only parameter.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Reset all settings to factory defaults Reset all settings in unit to factory settings. If you're getting crazy voltage readings in a unit after upgrading firmware, use this then reconfigure the unit.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Do nothing |
1 | Reset to factory defaults |
The manufacturer defined default value is 0
(Do nothing).
This parameter has the configuration ID config_255_4_wo
and is of type INTEGER
.
This is a write only parameter.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSB09 supports 3 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_METER_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.