DSB45 - ZWave |
{% include base.html %}
This describes the Z-Wave device DSB45, manufactured by AEON Labs with the thing type UID of aeon_dsb45_00_000
.
The device is in the category of Sensor, defining Device used to measure something.
The DSB45 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The DSB45 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The DSB45 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
To wake up the sensor, don't push the wake up button, as it does nothing. Instead, tap the zwave button once. Use wake up button to put back to sleep immediately.
Press WakeUp button or hold z-wave button
The Water Sensor will keep waking up for 8 seconds after sending the wake up notification command.
The Water Sensor will keep waking up for 8 seconds to waiting for the next command after receiving a command.
The Water Sensor will be woken up for 10 minutes when power is on (configurable).
There are 3 ways to exit the Wake up 10 minutes state:
- Triple click the tamper switch, and the Water Sensor will sleep immediately
- Receive the “Wake up no more information CC” command , sleep right now;
- Receive the other command except “Wake up no more information CC” , the Water Sensor will wake up for 8 seconds and then go to sleep.
The following table summarises the channels available for the DSB45 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Binary Sensor | sensor_binary | Door | Switch |
Flood Alarm | alarm_flood | Door | Switch |
Battery Level | battery-level | Battery | Number |
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if the flood alarm is triggered.
The alarm_flood
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 5 configuration parameters available in the DSB45. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Sensor Binary Report | Toggle the sensor binary report value |
2 | Wake up | Enable wake up 10 minutes when the power is switched on. |
3 | Basic set value | Toggle the basic set value when the Magnet switch is opened /closed. |
121 | Reports that will be sent | configuration Value 4(LSB) |
121 | Parameter 121 Value 3 | See documentation |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Toggle the sensor binary report value
The following option values may be configured -:
Value | Description |
---|---|
0 | Open: 00, Close: FF |
1 | Open: FF, Close: 00 |
The manufacturer defined default value is 0
(Open: 00, Close: FF).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Enable wake up 10 minutes when the power is switched on.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Toggle the basic set value when the Magnet switch is opened /closed.
The following option values may be configured -:
Value | Description |
---|---|
0 | Open: 00, Close: FF |
1 | Open: FF, Close: 00 |
The manufacturer defined default value is 0
(Open: 00, Close: FF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
configuration Value 4(LSB) See documentation for bytes
Setting to 1 send BATTERY
Setting to 16 sends SENSOR BINARY
Setting to 17 sends SENSOR BINARY and BATTERY The following option values may be configured -:
Value | Description |
---|---|
0 | Do not send anything |
1 | Send battery report |
16 | Send Sensor Binary report |
17 | Send Sensor Binary and Battery reports |
The manufacturer defined default value is 0
(Do not send anything).
This parameter has the configuration ID config_121_4_000000FF
and is of type INTEGER
.
See documentation set to 1 sends BASIC SET
set to 16 sends ALARM
set to 17 sends ALARM and BASIC SET The following option values may be configured -:
Value | Description |
---|---|
0 | Do not send anything |
1 | Send Basic Set |
16 | Send ALARM |
17 | Send Basic Set and ALARM |
The manufacturer defined default value is 1
(Send Basic Set).
This parameter has the configuration ID config_121_4_0000FF00
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSB45 supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |