DSC10 Heavy Duty Smart Switch

This describes the Z-Wave device DSC10, manufactured by AEON Labs with the thing type UID of aeon_dsc10_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

DSC10 product image

The DSC10 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Aeotec by Aeon Labs Heavy Duty Smart Switch Gen5.

Heavy Duty Smart Switch Gen5 has been crafted to power connected lighting using Z-Wave Plus. It is powered by Aeotec’s Gen5 technology. 

To see whether Heavy Duty Smart Switch Gen5 is known to be compatible with your Z-Wave system or not, please reference our Z-Wave gateway comparison listing. The technical specifications of Heavy Duty Smart Switch Gen5can be viewed at that link.

Familiarize** yourself with your Heavy Duty Smart Switch Gen5.**

Action button: Used for Heavy Duty Smart Switch Z-Wave network inclusion and exclusion and to manually turn on or off.

Status LED: Indicates your Heavy Duty Smart Switch's status. (While unpaired, this LED will blink slowly constantly).

**Terminals: **There are two groups of terminals. As marked, mains power is to be connected to AC Power and the electric load to Load.

Heavy Duty Smart Switch Gen5 current can not exceed 40 amps.

Inclusion Information

Your Heavy Duty Smart Switch must be paired with a Z-Wave network  before it can receive wireless commands or report the energy consumption of the attached electronics.

** 
**

**Note: **The LED on your Heavy Duty Smart Switch will blink if it is not currently paired with a Z-Wave network. 

Tip: Turn off any devices connected to your Heavy Duty Smart Switch before adding or removing it to/from a Z-Wave network. This will help to prevent load damage. 

Adding your Heavy Duty Smart Switch Gen5 to a Z-Wave network.

Pairing your Heavy Duty Smart Switch Gen5 into your existing Z-Wave network.

  1. Place your gateway or controller into Z-Wave pair or inclusion mode. (Please refer to your controller/gateway manual on how to do this)

  2. Press the Action Button on your Switch.

  3. If your switch has been successfully linked to your network, its LED will no longer blink. If linking was unsuccessful, the LED will continue to blink.

Exclusion Information

Unpairing your Heavy Duty Smart Switch Gen5 from your existing Z-Wave network

  1. Place your gateway or controller into Z-Wave unpair or exclusion mode. (Please refer to your controller/gateway manual on how to do this)

  2. Press the Action Button on your Switch.

  3. If your switch has been successfully unlinked to your network, its LED will begin to blink. If linking was unsuccessful, the LED will return to its last LED state.

General Usage Information

Turn your Heavy Duty Smart Switch Gen5 on or off.

Your Heavy Duty Smart Switch can be turned on or off through the use of  Z-Wave commands built into Z- Wave certified controllers and gateways. The specific Z-Wave commands supporting this function are the Basic Command Class and Binary Switch Command Class. 

Monitoring power consumption.

Your Heavy Duty Smart Switch can report Watts energy usage or kWh energy usage to a Z-Wave gateway or controller. If this function is supported by the gateway/controller, your energy consumption will be displayed within its user interface. The specific Z-Wave commands supporting energy monitoring are the Meter Command Class and Multilevel Sensor Command Class. Automatic reports go to association group 1, which is setup via the  Association Command Class. 

More advanced configurations.

The Smart Switch Gen5 has a longer list of device configurations that you can do with Smart Switch Gen5. 

You can find the configuration sheet here: https://aeotec.freshdesk.com/helpdesk/attachments/6052990296

The temperature sensor only measures the internal temperature of product (Circuit board).

Channels

The following table summarises the channels available for the DSC10 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the DSC10. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Current Overload Protection See overview
20 Output Load Status Configure the output load status after re‐power on.
80 Notification on Status Change The type of report to send when the device status changes
90 Enables/disables parameter 91/92
91 Minimum Change to send Report (Watt) The value represents the minimum change in wattage for a Report to be sent.
92 Minimum Change to send Report (%) The minimum change in wattage Percent for a report to be sent
200 Partner ID
252 Lock/unlock Configuration Changes
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Current Overload Protection

See overview Load will be closed when the Current more than 39.5A and the time more than 5 seconds. The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Activate Overload Protection
1 Deactivate Overload Protection

The manufacturer defined default value is 0 (Activate Overload Protection).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 20: Output Load Status

Configure the output load status after re‐power on.

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 Last Status
1 Always ON
2 Always OFF

The manufacturer defined default value is 0 (Last Status).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 80: Notification on Status Change

The type of report to send when the device status changes

The following option values may be configured -:

Value Description
0 Nothing
1 Hail
2 Basic CC Report

The manufacturer defined default value is 0 (Nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 90: Enables/disables parameter 91/92

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Enable parameters 91 and 92
1 Disable parameters 91 and 92

The manufacturer defined default value is 0 (Enable parameters 91 and 92).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Minimum Change to send Report (Watt)

The value represents the minimum change in wattage for a Report to be sent.

Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum Change to send Report (%)

The minimum change in wattage Percent for a report to be sent

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 200: Partner ID

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Aeon Labs
1 Other

The manufacturer defined default value is 0 (Aeon Labs).

This parameter has the configuration ID config_200_1 and is of type INTEGER. This is a read only parameter.

Parameter 252: Lock/unlock Configuration Changes

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Unlocked
1 Locked

The manufacturer defined default value is 0 (Unlocked).

This parameter has the configuration ID config_252_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DSC10 supports 2 association groups.

Group 1: Group 1

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_METER_V3
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_HAIL_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links