This describes the Z-Wave device DSC11, manufactured by AEON Labs with the thing type UID of aeon_dsc11_00_000
.
The device is in the category of Light Bulb, defining Devices that illuminate something, such as bulbs, etc..
The DSC11 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Update command classes -:
METER:5 :: ADD
METER:6 :: ADD
The following table summarises the channels available for the DSC11 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Electric meter (kWh) entire strip | meter_kwh | Energy | Number |
Electric meter (watts) entire strip | meter_watts | Energy | Number |
Switch 1 | switch_binary1 | Switch | Switch |
Electric meter (kWh) 1 | meter_kwh1 | Energy | Number |
Electric meter (watts) 1 | meter_watts1 | Energy | Number |
Switch 2 | switch_binary2 | Switch | Switch |
Electric meter (kWh) 2 | meter_kwh2 | Energy | Number |
Electric meter (watts) 2 | meter_watts2 | Energy | Number |
Switch 3 | switch_binary3 | Switch | Switch |
Electric meter (kWh) 3 | meter_kwh3 | Energy | Number |
Electric meter (watts) 3 | meter_watts3 | Energy | Number |
Switch 4 | switch_binary4 | Switch | Switch |
Electric meter (kWh) 4 | meter_kwh4 | Energy | Number |
Electric meter (watts) 4 | meter_watts4 | Energy | Number |
Switch 5 | switch_binary5 | Switch | Switch |
Electric meter (kWh) 5 | meter_kwh5 | Energy | Number |
Electric meter (watts) 5 | meter_watts5 | Energy | Number |
Switch 6 | switch_binary6 | Switch | Switch |
Electric meter (kWh) 6 | meter_kwh6 | Energy | Number |
Electric meter (watts) 6 | meter_watts6 | Energy | Number |
Entire strip
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary1
channel supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary2
channel supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh2
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts2
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary3
channel supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh3
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts3
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary4
channel supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh4
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts4
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary5
channel supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh5
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts5
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary6
channel supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh6
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts6
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 26 configuration parameters available in the DSC11. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Voltage to calculate power | Line voltage used for device calculations of wattage |
4 | Selective Reporting | Enable selective reporting only when power changes |
5 | Wattage Threshold - Whole strip | Threshold change in wattage to induce a automatic report |
6 | Wattage Threshold - Socket 1 | Threshold change in wattage to induce a automatic report |
7 | Wattage Threshold - Socket 2 | Threshold change in wattage to induce a automatic report |
8 | Wattage Threshold - Socket 3 | Threshold change in wattage to induce a automatic report |
9 | Wattage Threshold - Socket 4 | Threshold change in wattage to induce a automatic report |
10 | Wattage Threshold - Socket 5 | Threshold change in wattage to induce a automatic report |
11 | Wattage Threshold - Socket 6 | Threshold change in wattage to induce a automatic report |
12 | Percent Change - Whole Strip | Percentage change in wattage to induce a automatic report |
13 | Percent Change - Socket 1 | Percentage change in wattage to induce a automatic report |
14 | Percent Change - Socket 2 | Percentage change in wattage to induce a automatic report |
15 | Percent Change - Socket 3 | Percentage change in wattage to induce a automatic report |
16 | Percent Change - Socket 4 | Percentage change in wattage to induce a automatic report |
17 | Percent Change - Socket 5 | Percentage change in wattage to induce a automatic report |
18 | Percent Change - Socket 6 | Percentage change in wattage to induce a automatic report |
80 | Status of load changed report | Status of load changed,send group 1 |
90 | Get Temperature | Get temperature of Smart Strip |
100 | Reset 0x65~0x67 to default value | Reset 0x65~0x67 to default value |
101 | select channels to report consumtion as item 1 | A binary field for reporting consumption (kWh) of channels |
101 | Select channels to report power as item 1 | A binary field to choose channels to report power |
102 | Item 2 (kWh) | Channel(s) to auto-report kWh |
102 | Item 2 (power) | Channel(s) to auto-report wattage |
111 | Interval to send out reports of Group 1 | |
112 | Interval to send out reports of Group 2 | |
113 | Interval to send out reports of Group 3 | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Line voltage used for device calculations of wattage
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 120
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
Enable selective reporting only when power changes Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. Values in the range 0 to 16 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Threshold change in wattage to induce a automatic report Threshold change in wattage to induce a automatic report (Whole HEM). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
Threshold change in wattage to induce a automatic report Threshold change in wattage to induce a automatic report (Socket 1). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
Threshold change in wattage to induce a automatic report Threshold change in wattage to induce a automatic report (Socket 2). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_7_2
and is of type INTEGER
.
Threshold change in wattage to induce a automatic report Threshold change in wattage to induce a automatic report (Socket 3). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
Threshold change in wattage to induce a automatic report Threshold change in wattage to induce a automatic report (Socket 4). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_9_2
and is of type INTEGER
.
Threshold change in wattage to induce a automatic report Threshold change in wattage to induce a automatic report (Socket 5). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Threshold change in wattage to induce a automatic report Threshold change in wattage to induce a automatic report (Socket 6). (Valid values 0-60000) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
Percentage change in wattage to induce a automatic report Percentage change in wattage to induce a automatic report (Whole Smart Strip). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Percentage change in wattage to induce a automatic report Percentage change in wattage to induce a automatic report (Socket 1). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Percentage change in wattage to induce a automatic report Percentage change in wattage to induce a automatic report (Socket 2). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Percentage change in wattage to induce a automatic report Percentage change in wattage to induce a automatic report (Socket 3). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Percentage change in wattage to induce a automatic report Percentage change in wattage to induce a automatic report (Socket 4). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Percentage change in wattage to induce a automatic report Percentage change in wattage to induce a automatic report (Socket 5). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Percentage change in wattage to induce a automatic report Percentage change in wattage to induce a automatic report (Socket 6). (Valid values 0-100) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Status of load changed,send group 1 Status of load changed,send group 1 associate nodes Hail CC or Basic report CC. The following option values may be configured -:
Value | Description |
---|---|
0 | Not sent |
1 | Send Hail |
2 | Send Basic |
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_80_4
and is of type INTEGER
.
Get temperature of Smart Strip Get temperature of Smart Strip (Only GET is valid) Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_90_2
and is of type INTEGER
.
Reset 0x65~0x67 to default value
The following option values may be configured -:
Value | Description |
---|---|
0 | Reset |
The manufacturer defined default value is 0
(Reset).
This parameter has the configuration ID config_100_1
and is of type INTEGER
.
A binary field for reporting consumption (kWh) of channels Choose the channel or channels to auto-report kWh based on a time interval set in parameter 111. This is the LSB
1 - report only a summary of all channels ( bit 1)
2 - report channel 1 wattage (bit 2)
3 - report a summary of all channels and channel 1 (bits 1 and 2)
4 - report channel 2 wattage
<...>
14 - channel 3, channel 2, and channel 1
15 - channel 3, channel 2, channel 1, and summary
etc.
127 - in the end is reporting values for each individual channel (1-6) and the summary data. In binary, bits 1 through 7 set to 1.
The bit values are as follows:
1 - summary report
2 - channel 1 report
4 - channel 2 report
8 - channel 3 report
16 - channel 4 report
32 - channel 5 report
64 - channel 6 report Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_101_4_000000FF
and is of type INTEGER
.
A binary field to choose channels to report power Choose the channel or channels to auto-report wattage based on a time interval set in parameter 111.
** examples:**
1 - report only a summary of all channels ( bit 1)
2 - report channel 1 wattage (bit 2)
3 - report a summary of all channels and channel 1 (bits 1 and 2)
4 - report channel 2 wattage
<...>
14 - channel 3, channel 2, and channel 1
15 - channel 3, channel 2, channel 1, and summary
etc.
127 - in the end is reporting values for each individual channel (1-6) and the summary data. In binary, bits 1 through 7 set to 1.
The bit values are as follows:
1 - summary report
2 - channel 1 report
4 - channel 2 report
8 - channel 3 report
16 - channel 4 report
32 - channel 5 report
64 - channel 6 report Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_101_4_0000FF00
and is of type INTEGER
.
Channel(s) to auto-report kWh Choose the channel or channels to auto-report kWh based on a time interval set in parameter 112. This is the LSB
1 - report only a summary of all channels ( bit 1)
2 - report channel 1 wattage (bit 2)
3 - report a summary of all channels and channel 1 (bits 1 and 2)
4 - report channel 2 wattage
<...>
14 - channel 3, channel 2, and channel 1
15 - channel 3, channel 2, channel 1, and summary
etc.
127 - in the end is reporting values for each individual channel (1-6) and the summary data. In binary, bits 1 through 7 set to 1.
The bit values are as follows:
1 - summary report
2 - channel 1 report
4 - channel 2 report
8 - channel 3 report
16 - channel 4 report
32 - channel 5 report
64 - channel 6 report Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_102_4_000000FF
and is of type INTEGER
.
Channel(s) to auto-report wattage Choose the channel or channels to auto-report wattage based on a time interval set in parameter 112.
** examples:**
1 - report only a summary of all channels ( bit 1)
2 - report channel 1 wattage (bit 2)
3 - report a summary of all channels and channel 1 (bits 1 and 2)
4 - report channel 2 wattage
<...>
14 - channel 3, channel 2, and channel 1
15 - channel 3, channel 2, channel 1, and summary
etc.
127 - in the end is reporting values for each individual channel (1-6) and the summary data. In binary, bits 1 through 7 set to 1.
The bit values are as follows:
1 - summary report
2 - channel 1 report
4 - channel 2 report
8 - channel 3 report
16 - channel 4 report
32 - channel 5 report
64 - channel 6 report Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_102_4_0000FF00
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSC11 supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.