Skip to content

Latest commit

 

History

History
241 lines (127 loc) · 6.89 KB

dsc14_0_0.md

File metadata and controls

241 lines (127 loc) · 6.89 KB
layout title
documentation
DSC14 - ZWave

{% include base.html %}

DSC14 Micro Motor Controller

This describes the Z-Wave device DSC14, manufactured by AEON Labs with the thing type UID of aeon_dsc14_00_000.

The DSC14 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the DSC14 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Dimmer switch_dimmer DimmableLight Dimmer

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the DSC14. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Type of Sensor Report
2 Blinking Behavior
80 Notification on Status Change
90 Disable automated reporting
91 Minimum Change to send Report (Watt)
92 Minimum Change to send Report (%)
101 reports to send automatically
102 Which reports to send automatically to group 2
103 Which reports to send automatically to group 3
111 Interval to send out reports of group 1
112 Interval to send out reports of group 2
113 Interval to send out reports of group 3

Parameter 1: Type of Sensor Report

The following option values may be configured -:

Value Description
0 Power
1 Voltage

The manufacturer defined default value is 0 (Power).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Blinking Behavior

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 80: Notification on Status Change

The following option values may be configured -:

Value Description
0 Nothing
1 Hail
2 Basic CC Report

The manufacturer defined default value is 0 (Nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 90: Disable automated reporting

Disables Function of automated sending of a Report triggered by minimal change of value. The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Minimum Change to send Report (Watt)

Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum Change to send Report (%)

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 101: reports to send automatically

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Which reports to send automatically to group 2

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Which reports to send automatically to group 3

The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 111: Interval to send out reports of group 1

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Interval to send out reports of group 2

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Interval to send out reports of group 3

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DSC14 supports 1 association group.

Group 1: Group 1

Status Reports

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.