This describes the Z-Wave device DSC14, manufactured by AEON Labs with the thing type UID of aeon_dsc14_00_000
.
The DSC14 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the DSC14 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 12 configuration parameters available in the DSC14. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Type of Sensor Report | |
2 | Blinking Behavior | |
80 | Notification on Status Change | |
90 | Disable automated reporting | |
91 | Minimum Change to send Report (Watt) | |
92 | Minimum Change to send Report (%) | |
101 | reports to send automatically | |
102 | Which reports to send automatically to group 2 | |
103 | Which reports to send automatically to group 3 | |
111 | Interval to send out reports of group 1 | |
112 | Interval to send out reports of group 2 | |
113 | Interval to send out reports of group 3 |
The following option values may be configured -:
Value | Description |
---|---|
0 | Power |
1 | Voltage |
The manufacturer defined default value is 0
(Power).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Nothing |
1 | Hail |
2 | Basic CC Report |
The manufacturer defined default value is 0
(Nothing).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Disables Function of automated sending of a Report triggered by minimal change of value. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSC14 supports 1 association group.
Status Reports
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |