DSC17 Micro Double Smart Switch

This describes the Z-Wave device DSC17, manufactured by AEON Labs with the thing type UID of aeon_dsc17_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

DSC17 product image

The DSC17 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the DSC17 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Sensor (power) sensor_power Energy Number
Electric meter (watts) meter_watts Energy Number
Electric meter (kWh) meter_kwh Energy Number
Reset Meter meter_reset Energy Switch
Switch 1 switch_binary1 Switch Switch
Switch 2 switch_binary2 Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset Meter

Reset the meter.

The meter_reset channel supports the Switch item and is in the Energy category.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 16 configuration parameters available in the DSC17. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Blink This is a double byte value.
3 Current Overload Protection Load current>=10.A,2 minutes later ,automatic turn off the load
80 Notification on Status Change Enables automatic notifications to associated devices
90 Enables/disables parameter 91 and 92 Automated sending of a Report triggered by minimal change of value.
91 Minimum Change to send Report (Watt) The value represents the minimum change in Watts for a Report to be sent
92 Minimum Change to send Report (%) The value represents the min. change in Watts Percent for a report to be sent
100 Set 101-103 to default.
101 Automatic reports for group 1 Which reports need to send automatically in timing intervals for group 1
102 Automatic reports for group 2 Which reports need to send automatically in timing intervals for group 2
103 Automatic reports for group 3 Which reports need to send automatically in timing intervals for group 3
110 Set 111-113 to default.
111 Interval to send out reports of group 1
112 Interval to send out reports of group 2
113 Interval to send out reports of group 3
120 Set External Switch/Button Control mode
255 Reset to the default Configuration.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 2: Blink

This is a double byte value. This is a double byte value. The LSB defines the total time the device need to blink. The value is set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.

Configuration Value 1 is to Specify the time that Micro Double SES need blink, The unit is Second; Configuration Value 2 is to Specify the Cycle of on/off, the unit of it is 0.1 second. For example: if we set Configuration Value 1 to '15',Configuration Value 2 to '10',then Micro Double SES will open 0.5 second, close 0.5 second, and repeat for 14 times.  Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Current Overload Protection

Load current>=10.A,2 minutes later ,automatic turn off the load

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 80: Notification on Status Change

Enables automatic notifications to associated devices Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Smart Switch's load changed The following option values may be configured -:

Value Description
0 nothing
1 Hail CC Sent
2 Basic CC Report Sent

The manufacturer defined default value is 0 (nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 90: Enables/disables parameter 91 and 92

Automated sending of a Report triggered by minimal change of value. Parameter to Enable/Disable automated sending of a Report triggered by minimal change of value. The following option values may be configured -:

Value Description
0 Deavtivate
1 Activate

The manufacturer defined default value is 0 (Deavtivate).

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 91: Minimum Change to send Report (Watt)

The value represents the minimum change in Watts for a Report to be sent

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_91_2 and is of type INTEGER.

Parameter 92: Minimum Change to send Report (%)

The value represents the min. change in Watts Percent for a report to be sent

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_92_1 and is of type INTEGER.

Parameter 100: Set 101-103 to default.

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_100_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 101: Automatic reports for group 1

Which reports need to send automatically in timing intervals for group 1 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. The following option values may be configured, in addition to values in the range 0 to 15 -:

Value Description
0 Disabled
1 Voltage
2 Current
4 Wattage
8 kWh
15 All Values

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Automatic reports for group 2

Which reports need to send automatically in timing intervals for group 2 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. The following option values may be configured, in addition to values in the range 0 to 15 -:

Value Description
0 Disabled
1 Voltage
2 Current
4 Wattage
8 kWh
15 All Values

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Automatic reports for group 3

Which reports need to send automatically in timing intervals for group 3 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. The following option values may be configured, in addition to values in the range 0 to 15 -:

Value Description
0 Disabled
1 Voltage
2 Current
4 Wattage
8 kWh
15 All Values

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 110: Set 111-113 to default.

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_110_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 111: Interval to send out reports of group 1

Values in the range 1 to 2678400 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_111_4 and is of type INTEGER.

Parameter 112: Interval to send out reports of group 2

Values in the range 1 to 2678400 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 113: Interval to send out reports of group 3

Values in the range 1 to 2678400 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_113_4 and is of type INTEGER.

Parameter 120: Set External Switch/Button Control mode

The following option values may be configured -:

Value Description
0 Momentary button mode
1 2-state switch mode
255 Unidentified mode

The manufacturer defined default value is 255 (Unidentified mode).

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Parameter 255: Reset to the default Configuration.

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_255_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DSC17 supports 3 association groups.

Group 1: Group 1

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Group 3: Group 3

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V3
COMMAND_CLASS_METER_V2
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.