Skip to content

Latest commit

 

History

History
180 lines (109 loc) · 5.69 KB

dsd31_0_0.md

File metadata and controls

180 lines (109 loc) · 5.69 KB
layout title
documentation
DSD31 - ZWave

{% include base.html %}

DSD31 Outlet Plugable Siren

This describes the Z-Wave device DSD31, manufactured by AEON Labs with the thing type UID of aeon_dsd31_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

DSD31 product image

The DSD31 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the DSD31 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Siren sound and volume config_decimal Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Siren sound and volume

Generic class for configuration parameter.

The config_decimal channel supports the Number item.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the DSD31. Detailed information on each parameter can be found in the sections below.

Param Name Description
37 Sirensound and Volume Sets the sound type and volume
37 Siren Sound
37 Siren Volume
80 Send Notifications send notifications to associated devices
252 Enable/Disable 'Lock' - Configuration

Parameter 37: Sirensound and Volume

Sets the sound type and volume The Value1(low byte) is used to select the Siren sound. The Value2(high byte) is used to adjust the volume. Other values will be ignored. 0 1  ->   do not change the current sound.1 1  ->   Siren sound 1 is selected.2 1  ->   Siren sound 2 iThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 13.

This parameter has the configuration ID config_37_2 and is of type INTEGER.

Parameter 37: Siren Sound

The following option values may be configured -:

Value Description
1 Siren Sound 1
2 Siren Sound 2
3 Siren Sound 3
4 Siren Sound 4
5 Siren Sound 5

The manufacturer defined default value is 1 (Siren Sound 1).

This parameter has the configuration ID config_37_2_0000000F and is of type INTEGER.

Parameter 37: Siren Volume

The following option values may be configured -:

Value Description
1 88dB
2 100dB
3 105dB

The manufacturer defined default value is 3 (105dB).

This parameter has the configuration ID config_37_2_00000F00 and is of type INTEGER.

Parameter 80: Send Notifications

send notifications to associated devices Enable to send notifications to associated devices when the state of Siren changed. The following option values may be configured -:

Value Description
0 Nothing
1 Hail CC
2 Basic CC Report

The manufacturer defined default value is 0 (Nothing).

This parameter has the configuration ID config_80_1 and is of type INTEGER.

Parameter 252: Enable/Disable 'Lock' - Configuration

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_252_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DSD31 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.