This describes the Z-Wave device ZW132, manufactured by AEON Labs with the thing type UID of aeon_zw132_00_000
.
This version of the device is limited to firmware versions below 1.9
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZW132 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Aeotec Dual Nano Switch is a low-cost Z-Wave Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status.
It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch.
The Dual Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Reset your Dual Nano Switch.
If at some stage, your primary controller is missing or inoperable, you may wish to reset all of your Dual Nano Switch’s settings to their factory defaults. To do this, press and hold the Action Button for 20 seconds and then release it. Your Dual Nano Switch will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colourful gradient status as a confirmation.
Including Dual Nano Switch as a non-secure device:
If you want your Dual Nano Switch as a non-secure device in your Z-Wave network, press the Action Button once on Dual Nano Switch when you pair it to your gateway. If inclusion is successful, the green LED will be on for 2 seconds, and then return to a solid indication. If inclusion is unsuccessful, the red LED will be on for 2 seconds and then return to a colourful gradient.
Including Dual Nano Switch as a secure device:
In order to take full advantage of the Dual Nano Switch, you will want your Dual Nano Switch as a security device that uses encrypted messages to communicate in your Z-wave network. A security enabled controller/gateway (or Z-Wave Plus controller) is required.
- Set your Z-Wave Plus controller into pairing mode.
- Press the Action Button 2 times within 1 second on the Dual Nano Switch, the blue LED (secure indication) will blink to indicate the Dual Nano Switch is entering into secure pairing mode.
- If the Dual Nano Switch has been successfully added to your Z-Wave network, its RGB LED will be solid. If the pairing was unsuccessful, the red LED will be on for 2 seconds and then remain a colourful gradient, repeat the instructions above from step 1.
Removing Dual Nano Switch from a Z-Wave network.
Your Dual Nano Switch can be removed from your Z-Wave network at any time. You’ll need to use your Z-Wave network’s main controller. To set your Z-Wave controller/gateway into removal mode, please refer to the respective section within your controller instruction manual.
- Set your Z-Wave controller into removal mode.
- Press the Action Button on the Dual Nano Switch or toggle the external manual switch 3 times in fast succession.
- If the Dual Nano Switch has been successfully removed from your Z-Wave network, its RGB LED will remain colourful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load), repeat the instructions above from step 1.
The following table summarises the channels available for the ZW132 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Scene Number | scene_number | Number | |
Electric meter (kWh) | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
Electric meter (amps) | meter_current | Energy | Number |
Electric meter (volts) | meter_voltage | Energy | Number |
Reset Meter | meter_reset | Energy | Switch |
Alarm (power) | alarm_power | Energy | Switch |
Alarm (heat) | alarm_heat | Fire | Switch |
Clock Time Offset | time_offset | Temperature | Number |
Switch 1 | switch_binary1 | Switch | Switch |
Electric meter (kWh) 1 | meter_kwh1 | Energy | Number |
Electric meter (watts) 1 | meter_watts1 | Energy | Number |
Electric meter (amps) 1 | meter_current1 | Energy | Number |
Electric meter (volts) 1 | meter_voltage1 | Energy | Number |
Switch 2 | switch_binary2 | Switch | Switch |
Electric meter (kWh) 2 | meter_kwh2 | Energy | Number |
Electric meter (watts) 2 | meter_watts2 | Energy | Number |
Electric meter (amps) 2 | meter_current2 | Energy | Number |
Electric meter (volts) 2 | meter_voltage2 | Energy | Number |
Reset Meter 2 | meter_reset2 | Energy | Switch |
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel supports the Switch
item and is in the Energy
category.
Indicates if a power alarm is triggered.
The alarm_power
channel supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if a heat alarm is triggered.
The alarm_heat
channel supports the Switch
item and is in the Fire
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Provides the current time difference for the devices time.
The time_offset
channel supports the Number
item and is in the Temperature
category.
Switch the power on and off.
The switch_binary1
channel supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage1
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary2
channel supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh2
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts2
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current2
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage2
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset2
channel supports the Switch
item and is in the Energy
category.
The following table provides a summary of the 24 configuration parameters available in the ZW132. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Current Overload Protection. | Output load will be closed after 30 seconds if the current exceeds 10.5A |
4 | Overheat protection | Output load will be closed after 30 secs if the temp inside exceeds 100 C |
20 | Configure the output status after re-power on it. | Configure the output status after re-power on it. |
80 | Group 1 notifications | To set which notification would be sent to the associated devices (Group 1) |
81 | Group 3 notifications | To set which notification would be sent to association group 3 |
82 | Group 4 notifications | To set which notification would be sent to association group 4 |
83 | LED State | Configure the state of LED |
84 | Night light on/off | Time to turn the light on and off |
90 | Enables/disables parameter 91 and 92 below: | Enables/disables parameter 91 and 92 below: |
91 | Set the threshold value of wattage. | Set the threshold value of wattage. |
92 | Set the threshold value of wattage. | Set the threshold value of wattage. |
100 | Set parameter 101-103 to default value | Reset the parameter 101-103 |
101 | Set group 1 reports | To set which reports need to be sent in Report group 1 |
102 | To set which reports will be sent in Report g2 | To set which reports will be sent in Report group 2. |
103 | To set which reports will be sent in Report g3 | To set which reports need to be sent in Report group 3. |
110 | Set parameter 111-113 to default value. | Set parameter 111-113 to default value. |
111 | Set the interval of automatic report for Report G1 | Set the interval of automatic report for Report group 1. |
112 | Set the interval of automatic report for Report G2 | Set the interval of automatic report for Report group 2. |
113 | Set the interval of automatic report for Report G3 | Set the interval of automatic report for Report group 3. |
120 | Configure the external switch mode for S1 | Configure the external switch mode for S1 |
121 | Configure the external switch mode for S2. | Configure the external switch mode for S2. |
122 | Set the control destination for external switch | Set the control destination for external switch |
252 | Lock/unlock configuration parameters | Lock/unlock configuration parameters |
255 | Reset the Dual Nano Switch | Reset the Dual Nano Switch |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Output load will be closed after 30 seconds if the current exceeds 10.5A
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 1
(Enable).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Output load will be closed after 30 secs if the temp inside exceeds 100 C
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Configure the output status after re-power on it.
The following option values may be configured -:
Value | Description |
---|---|
0 | Last status |
1 | Always on |
2 | Always off |
The manufacturer defined default value is 0
(Last status).
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
To set which notification would be sent to the associated devices (Group 1) Note: When just only one channel load state is changed, the report message Hail CC or Basic Report CC would be Multi Channel encapsulated. The following option values may be configured -:
Value | Description |
---|---|
0 | Send Nothing |
1 | Send Hail CC |
2 | Send Basic CC report |
3 | Send Hail CC when using the manual switch |
The manufacturer defined default value is 3
(Send Hail CC when using the manual switch).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
To set which notification would be sent to association group 3 when using the external switch 1 to switch the loads. The following option values may be configured -:
Value | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
The manufacturer defined default value is 1
(Send Basic Set CC).
This parameter has the configuration ID config_81_1
and is of type INTEGER
.
To set which notification would be sent to association group 4 when using the external switch 2 to switch the loads. The following option values may be configured -:
Value | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
The manufacturer defined default value is 1
(Send Basic Set CC).
This parameter has the configuration ID config_82_1
and is of type INTEGER
.
Configure the state of LED
The following option values may be configured -:
Value | Description |
---|---|
0 | Energy mode |
1 | Momentary mode |
2 | Night light mode |
The manufacturer defined default value is 0
(Energy mode).
This parameter has the configuration ID config_83_1
and is of type INTEGER
.
Time to turn the light on and off value 1 = (range of 0 - 23) // ON (hour) value 2 = (range of 0 - 59) // ON (minute) value 3 = (range of 0 - 23) // OFF (hour) value 4 = (range of 0 - 59) // OFF (minute) It would be best to convert each value into HEX and input them like this: Parameter 84 = (value 1)(value 2)(value 3)(value 4) Using the default values it would look like this = (12)(00)(08)(00) converted to decimal is = 301991936 Values in the range 0 to 593044313 may be set.
The manufacturer defined default value is 301991936
.
This parameter has the configuration ID config_84_4
and is of type INTEGER
.
Enables/disables parameter 91 and 92 below:
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
Set the threshold value of wattage.
Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
Set the threshold value of wattage.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
Reset the parameter 101-103 This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_100_1_wo
and is of type INTEGER
.
This is a write only parameter.
To set which reports need to be sent in Report group 1 Sum the values of the options you want:
1 = Meter REPORT (kWh) of whole Channels
2 = Meter REPORT (Watt) of whole Channels
4 = Meter REPORT (V) of whole Channels
8 = Meter REPORT (A) of whole Channels
256 = Multi Channel Meter Report (W) on Channel 1
512 = Multi Channel Meter Report (W) on Channel 2
2048 = Multi Channel Meter Report (kWh) on Channel 1
4096 = Multi Channel Meter Report (kWh) on Channel 2
65536 = Multi Channel Meter Report (V) on Channel 1
131072 = Multi Channel Meter Report (V) on Channel 2
524288 = Multi Channel Meter Report (A) on Channel 1
1048576 = Multi Channel Meter Report (A) on Channel 2
1776399 = ALL ABOVE OPTIONS The following option values may be configured, in addition to values in the range 0 to 1776399 -:
Value | Description |
---|---|
1 | Send Meter Report of energy (kWh) |
2 | Send Meter Report of wattage (W) |
4 | Send Meter Report of voltage (V) |
8 | Send Meter Report of current (A) |
256 | Send Multi Channel Meter Report of wattage (W) C1 |
512 | Send Multi Channel Meter Report of wattage (W) C2 |
2048 | Send Multi Channel Meter Report of energy (kWh) C1 |
4096 | Send Multi Channel Meter Report of energy (kWh) C2 |
65536 | Send Multi Channel Meter Report of voltage (V) C1 |
131072 | Send Multi Channel Meter Report of voltage (V) C2 |
524288 | Send Multi Channel Meter Report of current (A) C1 |
1048576 | Send Multi Channel Meter Report of current (A) C2 |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
To set which reports will be sent in Report group 2.
Sum the values of the options you want:
1 = Meter REPORT (kWh) of whole Channels
2 = Meter REPORT (Watt) of whole Channels
4 = Meter REPORT (V) of whole Channels
8 = Meter REPORT (A) of whole Channels
256 = Multi Channel Meter Report (W) on Channel 1
512 = Multi Channel Meter Report (W) on Channel 2
2048 = Multi Channel Meter Report (kWh) on Channel 1
4096 = Multi Channel Meter Report (kWh) on Channel 2
65536 = Multi Channel Meter Report (V) on Channel 1
131072 = Multi Channel Meter Report (V) on Channel 2
524288 = Multi Channel Meter Report (A) on Channel 1
1048576 = Multi Channel Meter Report (A) on Channel 2
1776399 = ALL ABOVE OPTIONS The following option values may be configured, in addition to values in the range 0 to 1776399 -:
Value | Description |
---|---|
1 | Send Meter Report of energy (kWh) |
2 | Send Meter Report of wattage (W) |
4 | Send Meter Report of voltage (V) |
8 | Send Meter Report of current (A) |
256 | Send Multi Channel Meter Report of wattage (W) C1 |
512 | Send Multi Channel Meter Report of wattage (W) C2 |
2048 | Send Multi Channel Meter Report of energy (kWh) C1 |
4096 | Send Multi Channel Meter Report of energy (kWh) C2 |
65536 | Send Multi Channel Meter Report of voltage (V) C1 |
131072 | Send Multi Channel Meter Report of voltage (V) C2 |
524288 | Send Multi Channel Meter Report of current (A) C1 |
1048576 | Send Multi Channel Meter Report of current (A) C2 |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
To set which reports need to be sent in Report group 3. Sum the values of the options you want:
1 = Meter REPORT (kWh) of whole Channels
2 = Meter REPORT (Watt) of whole Channels
4 = Meter REPORT (V) of whole Channels
8 = Meter REPORT (A) of whole Channels
256 = Multi Channel Meter Report (W) on Channel 1
512 = Multi Channel Meter Report (W) on Channel 2
2048 = Multi Channel Meter Report (kWh) on Channel 1
4096 = Multi Channel Meter Report (kWh) on Channel 2
65536 = Multi Channel Meter Report (V) on Channel 1
131072 = Multi Channel Meter Report (V) on Channel 2
524288 = Multi Channel Meter Report (A) on Channel 1
1048576 = Multi Channel Meter Report (A) on Channel 2
1776399 = ALL ABOVE OPTIONS The following option values may be configured, in addition to values in the range 0 to 1776399 -:
Value | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
256 | Send Multi Channel Meter Report of wattage (W) C1 |
512 | Send Multi Channel Meter Report of wattage (W) C2 |
2048 | Send Multi Channel Meter Report of energy (kWh) C1 |
4096 | Send Multi Channel Meter Report of energy (kWh) C2 |
65536 | Send Multi Channel Meter Report of voltage (V) C1 |
131072 | Send Multi Channel Meter Report of voltage (V) C2 |
524288 | Send Multi Channel Meter Report of current (A) C1 |
1048576 | Send Multi Channel Meter Report of current (A) C2 |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Set parameter 111-113 to default value. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_110_1_wo
and is of type INTEGER
.
This is a write only parameter.
Set the interval of automatic report for Report group 1.
Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Set the interval of automatic report for Report group 2.
Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Set the interval of automatic report for Report group 3.
Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Configure the external switch mode for S1
The following option values may be configured -:
Value | Description |
---|---|
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Momentary push button mode |
4 | Enter automatic identification mode |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_120_1
and is of type INTEGER
.
Configure the external switch mode for S2.
The following option values may be configured -:
Value | Description |
---|---|
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Momentary push button mode |
4 | Enter automatic identification mode |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_121_1
and is of type INTEGER
.
Set the control destination for external switch
The following option values may be configured -:
Value | Description |
---|---|
1 | control the output loads of itself. |
2 | control the other nodes |
3 | control the output loads of itself and other nodes |
The manufacturer defined default value is 3
(control the output loads of itself and other nodes).
This parameter has the configuration ID config_122_1
and is of type INTEGER
.
Lock/unlock configuration parameters
The following option values may be configured -:
Value | Description |
---|---|
0 | Unlock |
1 | Lock |
The manufacturer defined default value is 0
(Unlock).
This parameter has the configuration ID config_252_1
and is of type INTEGER
.
Reset the Dual Nano Switch This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Nothing |
1 | Reset all params to factory default |
1431655765 | Reset factory settings and remove from network |
The manufacturer defined default value is 0
((Default) Nothing).
This parameter has the configuration ID config_255_4
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW132 supports 4 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. When the load state of Dual Nano Switch (turn on/off the load) is changed, the Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group.
Association group 1 supports 5 nodes.
Switch All, Scene Activation Set to associated nodes in Group 2 when the Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. (E.g. Send/forward Basic Set to control the other nodes in association Group
Association group 2 supports 5 nodes.
(configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated. Note: The Switch Mode of external switch S1 should be identified successfully, which means that the value of Configuration parameter 0x78 should be
Association group 3 supports 5 nodes.
Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated. Note: The Switch Mode of external switch S2 should be identified successfully, which means that the value of Configuration parameter
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_SECURITY_V1 |