This describes the Z-Wave device Da Vinci v9, manufactured by Avadesign Technology Co. with the thing type UID of avadesign_davinciv9_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The Da Vinci v9 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The Da Vinci wall controller is a Multi Chanel Z-Wave device that contains up to 6 relays and up to 9 touch buttons that can be set to control either the relays (On/Off switches and shutters) or any other on/off (SWITCH_BINARY) , shutter (MULTILEVEL_SWITCH) Z-Wave device.
Double Press the following buttons in the following order 8,1,3. Use the reset procedure only when the primary controller is missing or inoperable.
Press the #1 button 3 times.
Press the #1 button 3 times.
The following table summarises the channels available for the Da Vinci v9 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary1 | Switch | Switch |
Switch the power on and off.
The switch_binary1
channel supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 51 configuration parameters available in the Da Vinci v9. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Button 1 Type | button 1 Type |
2 | Button 1 Partner-Id | Button 1 Partner-Id |
3 | Button 1 Blind Duration | Button 1 Blind Duration |
4 | Button 1 Output | Button 1 Output |
5 | Button 1 attributes | Button 1 attributes |
6 | Button 2 Type | Button 2 Type |
7 | Button 2 Partner-Id | Button 2 Partner-Id |
8 | Button 2 Blind Duration | Button 2 Blind Duration |
9 | Button 2 Output | Button 2 Output |
10 | Button 2 attributes | Button 2 attributes |
11 | Button 3 Type | Button 3 Type |
12 | Button 3 Partner-Id | Button 3 Partner-Id |
13 | Button 3 Blind Duration | Button 3 Blind Duration |
14 | Button 1 Output | Button 1 Output |
15 | Button 3 attributes | Button 3 attributes |
16 | Button 4 Type | Button 4 Type |
17 | Button 4 Partner-Id | Button 4 Partner-Id |
18 | Button 4 Blind Duration | Button 4 Blind Duration |
19 | Button 4 Output | Button 4 Output |
20 | Button 4 attributes | Button 4 attributes |
21 | Button 5 Type | Button 5 Type |
22 | Button 5 Partner-Id | Button 5 Partner-Id |
23 | Button 5 Blind Duration | Button 5 Blind Duration |
24 | Button 5 Output | Button 5 Output |
25 | Button 5 attributes | Button 5 attributes |
26 | Button 6 Type | Button 6 Type |
27 | Button 6 Partner-Id | Button 6 Partner-Id |
28 | Button 6 Blind Duration | Button 6 Blind Duration |
29 | Button 6 Output | Button 6 Output |
30 | Button 6 attributes | Button 6 attributes |
31 | Button 7 Type | Button 7 Type |
32 | Button 7 Partner-Id | Button 7 Partner-Id |
33 | Button 7 Blind Duration | Button 7 Blind Duration |
34 | Button 7 Output | Button 7 Output |
35 | Button 7 attribute | Button 7 attribute |
36 | Button 8 Type | Button 8 Type |
37 | Button 8 Partner-Id | Button 8 Partner-Id |
38 | Button 8 Blind Duration | Button 8 Blind Duration |
39 | Button 8 Output | Button 8 Output |
40 | Button 8 attribute | Button 8 attribute |
41 | Button 9 Type | Button 9 Type |
42 | Button 9 Partner-Id | Button 9 Partner-Id |
43 | Button 9 Blind Duration | Button 9 Blind Duration |
44 | Button 9 Output | Button 9 Output |
45 | Button 9 attributes | Button 9 attributes |
46 | Device Led on intensity | Device Led on intensity |
47 | Device Led off intensity | Device Led off intensity |
48 | Device Toggle or Pulse the output | Device Toggle or Pulse the output |
49 | Device Background LEDs Timeout | Device Background LEDs Timeout |
50 | Device touch sensitivity | Device touch sensitivity |
51 | Save and Reset | Save and Reset |
button 1 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
0 | Null |
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Button 1 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
The manufacturer defined default value is 0
(0).
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Button 1 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | 3 Seconds |
10 | 10 Seconds |
30 | 30 Seconds |
60 | 60 Seconds |
90 | 90 Seconds |
120 | 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Button 1 Output Output = Relay The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 1
(Output number 1).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Button 1 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Button 2 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Button 2 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
The manufacturer defined default value is 0
(0).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Button 2 Blind Duration Possible values
3-127 The following option values may be configured -:
Value | Description |
---|---|
3 | 3 Seconds |
10 | 10 Seconds |
30 | 30 Seconds |
60 | 60 Seconds |
90 | 90 Seconds |
120 | 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Button 2 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 2
(Output number 2).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Button 2 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Button 3 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Button 3 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
The manufacturer defined default value is 0
(0).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Button 3 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | 3 Seconds |
30 | 30 Seconds |
60 | 60 Seconds |
90 | 90 Seconds |
120 | 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Button 1 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 3
(Output number 3).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Button 3 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Button 4 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Button 4 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Button 4 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | 3 Seconds |
30 | 30 Seconds |
60 | 60 Seconds |
90 | 90 Seconds |
120 | 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Button 4 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 4
(Output number 4).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Button 4 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Button 5 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Button 5 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
Button 5 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | Seconds |
30 | 30 Seconds |
60 | 60 Seconds |
90 | 90 Seconds |
120 | 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
Button 5 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 6
(Output number 6).
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
Button 5 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Button 6 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_26_1
and is of type INTEGER
.
Button 6 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_27_1
and is of type INTEGER
.
Button 6 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | 3 Seconds |
30 | 30 Seconds |
60 | 60 Seconds |
90 | 90 Seconds |
120 | 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_28_1
and is of type INTEGER
.
Button 6 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 6
(Output number 6).
This parameter has the configuration ID config_29_1
and is of type INTEGER
.
Button 6 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Button 7 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | On/Off Switch |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(On/Off Switch).
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
Button 7 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
Button 7 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | 3 Seconds |
30 | 30 Seconds |
60 | 60 Seconds |
90 | 90 Seconds |
120 | 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_33_1
and is of type INTEGER
.
Button 7 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_34_1
and is of type INTEGER
.
Button 7 attribute Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_35_1
and is of type INTEGER
.
Button 8 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_36_1
and is of type INTEGER
.
Button 8 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_37_1
and is of type INTEGER
.
Button 8 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | 3 Seconds |
30 | 30 Seconds |
60 | 60 Seconds |
90 | 90 Seconds |
120 | 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_38_1
and is of type INTEGER
.
Button 8 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
255 | BLANK |
The manufacturer defined default value is 0
(No output).
This parameter has the configuration ID config_39_1
and is of type INTEGER
.
Button 8 attribute Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Button 9 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_41_1
and is of type INTEGER
.
Button 9 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | 1 |
2 | 2 |
3 | 3 |
4 | 4 |
5 | 5 |
6 | 6 |
7 | 7 |
8 | 8 |
9 | 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_42_1
and is of type INTEGER
.
Button 9 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | 3 Seconds |
30 | 30 Seconds |
60 | 60 Seconds |
90 | 90 Seconds |
120 | 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_43_1
and is of type INTEGER
.
Button 9 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 0
(No output).
This parameter has the configuration ID config_44_1
and is of type INTEGER
.
Button 9 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_45_1
and is of type INTEGER
.
Device Led on intensity
Values in the range 0 to 7 may be set.
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_46_1
and is of type INTEGER
.
Device Led off intensity
Values in the range 0 to 7 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_47_1
and is of type INTEGER
.
Device Toggle or Pulse the output Device Toggle or Pulse the output:
0 = Toggle
1 = Pulse Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_48_1
and is of type INTEGER
.
Device Background LEDs Timeout Device Background LEDs Timeout:
0 = always Off
10 - 40 = Timeout in seconds
255 = always On!!!!!!! Values in the range 0 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_49_1
and is of type INTEGER
.
Device touch sensitivity You can choose value between 0 – 7
0 = most sensitive
7 = least sensitive Values in the range 0 to 7 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_50_1
and is of type INTEGER
.
Save and Reset 255 = save and reset The following option values may be configured -:
Value | Description |
---|---|
0 | |
255 | Save and Reset |
The manufacturer defined default value is 0
(0).
This parameter has the configuration ID config_51_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The Da Vinci v9 supports 37 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
EP1_SWITCH_BINARY_SET
Association group 2 supports 5 nodes.
EP1_SWITCH_BINARY_REPORT
Association group 3 supports 5 nodes.
EP1_SWITCH_MULTILEVEL_SET
Association group 4 supports 5 nodes.
EP1_SWITCH_MULTILEVEL_REPORT
Association group 5 supports 5 nodes.
EP2_SWITCH_BINARY_SET
Association group 6 supports 5 nodes.
EP2_SWITCH_BINARY_REPORT
Association group 7 supports 5 nodes.
EP2_SWITCH_MULTILEVEL_SET
Association group 8 supports 5 nodes.
EP2_SWITCH_MULTILEVEL_REPORT
Association group 9 supports 5 nodes.
EP3_SWITCH_BINARY_SET
Association group 10 supports 5 nodes.
EP3_SWITCH_BINARY_REPORT
Association group 11 supports 5 nodes.
EP3_SWITCH_MULTILEVEL_SET
Association group 12 supports 5 nodes.
EP3_SWITCH_MULTILEVEL_REPORT
Association group 13 supports 5 nodes.
EP4_SWITCH_BINARY_SET
Association group 14 supports 5 nodes.
EP4_SWITCH_BINARY_REPORT
Association group 15 supports 5 nodes.
EP4_SWITCH_MULTILEVEL_SET
Association group 16 supports 5 nodes.
EP4_SWITCH_MULTILEVEL_REPORT
Association group 17 supports 5 nodes.
EP5_SWITCH_BINARY_SET
Association group 18 supports 5 nodes.
EP5_SWITCH_BINARY_REPORT
Association group 19 supports 5 nodes.
EP5_SWITCH_MULTILEVEL_SET
Association group 20 supports 5 nodes.
EP5_SWITCH_MULTILEVEL_REPORT
Association group 21 supports 5 nodes.
EP6_SWITCH_BINARY_SET
Association group 22 supports 5 nodes.
EP6_SWITCH_BINARY_REPORT
Association group 23 supports 5 nodes.
EP6_SWITCH_MULTILEVEL_SET
Association group 24 supports 5 nodes.
EP6_SWITCH_MULTILEVEL_REPORT
Association group 25 supports 5 nodes.
EP7_ SWITCH_BINARY_SET
Association group 26 supports 5 nodes.
EP7_SWITCH_BINARY_REPORT
Association group 27 supports 5 nodes.
EP7_ SWITCH_MULTILEVEL_SET
Association group 28 supports 5 nodes.
EP7_ SWITCH_MULTILEVEL_REPORT
Association group 29 supports 5 nodes.
EP8_SWITCH_BINARY_SET
Association group 30 supports 5 nodes.
EP8_ SWITCH_BINARY_REPORT
Association group 31 supports 5 nodes.
EP8_ SWITCH_MULTILEVEL_SET
Association group 32 supports 5 nodes.
EP8_ SWITCH_MULTILEVEL_REPORT
Association group 33 supports 5 nodes.
EP9_ SWITCH_BINARY_SET
Association group 34 supports 5 nodes.
EP9_SWITCH_BINARY_REPORT
Association group 35 supports 5 nodes.
EP9_ SWITCH_MULTILEVEL_SET
Association group 36 supports 5 nodes.
EP9_ SWITCH_MULTILEVEL_REPORT
Association group 37 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.