layout | title |
---|---|
documentation |
doorSensor - ZWave |
{% include base.html %}
This describes the Z-Wave device doorSensor, manufactured by BeNext with the thing type UID of benext_doorsensor_00_000
.
The device is in the category of Door, defining Door sensors.
The doorSensor supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The doorSensor does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The doorSensor does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The following table summarises the channels available for the doorSensor -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Door Sensor | sensor_door | Door | Contact |
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Alarm (CO) | alarm_co | Door | Switch |
Battery Level | battery-level | Battery | Number |
Indicates if the door/window is open or closed.
The sensor_door
channel supports the Contact
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Contact
item type -:
Value | Label |
---|---|
OPEN | Open |
CLOSED | Closed |
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates if the carbon monoxide alarm is triggered.
The alarm_co
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 4 configuration parameters available in the doorSensor. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Reset to factory settings | Set all configuration values to default values (factory settings). |
2 | External contact behavior | Configure what the external contact sends when triggered. |
5 | Operating mode. | The main operating mode for the device. |
6 | Temperature offset | An offset for the temperature. |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Set all configuration values to default values (factory settings).
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Configure what the external contact sends when triggered.
The following option values may be configured -:
Value | Description |
---|---|
0 | Send alarm |
1 | Send basic frame |
The manufacturer defined default value is 0
(Send alarm).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
The main operating mode for the device.
The following option values may be configured -:
Value | Description |
---|---|
1 | Normal |
2 | Mode 1 report |
3 | Always-on |
The manufacturer defined default value is 1
(Normal).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
An offset for the temperature.
Values in the range -32768 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The doorSensor supports 2 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |