plugInDimmer Plug-in Dimmer

This describes the Z-Wave device plugInDimmer, manufactured by BeNext with the thing type UID of benext_plugindimmer_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

plugInDimmer product image

The plugInDimmer supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the plugInDimmer -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the plugInDimmer. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Reset to factory settings Set all configuration values to default values (factory settings).
4 Enable dimming This parameter is used to enable the dimming option of the product. When disabled the dimming and fading routine are disabled.
6 Maximum powerload The maximum powerload in watts when light is turned on, when measured higher then this value the Plugin Dimmer is automatically stops with dimming or is turned off.
7 Dimming speed The speed of dimming when activated (manual and RF). Dim speed is 1% per value (* 10 ms)
8 Fading up speed The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms)
11 Auto meter report: percentage A percentage that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 1% Maximum value = 100%
12 Auto meter report: watt A watt value that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 5 watt Maximum value = 255 watt
13 Auto meter report: time A time value that has to be passed compared to a previous sent value before a unsolicited meter report is sent. Minimum value = 10 seconds Maximum value = 255 seconds
14 Last known status What to do with lamp status when power applied. If 0x00: Always switch light off when power applied. If > 0x00: Switch lamp on/off depending on last known lampstatus before power was disconnected.
15 Fading down speed The speed of fading down when activated (manual and RF). Fade speed is 1% per value (* 10 ms)
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Reset to factory settings

Set all configuration values to default values (factory settings).

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 4: Enable dimming

This parameter is used to enable the dimming option of the product. When disabled the dimming and fading routine are disabled.

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 6: Maximum powerload

The maximum powerload in watts when light is turned on, when measured higher then this value the Plugin Dimmer is automatically stops with dimming or is turned off.

Values in the range 25 to 150 may be set.

The manufacturer defined default value is 125.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Dimming speed

The speed of dimming when activated (manual and RF). Dim speed is 1% per value (* 10 ms)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Fading up speed

The speed of fading up when activated (manual and RF). Fade speed is 1% per value (* 10 ms)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 11: Auto meter report: percentage

A percentage that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 1% Maximum value = 100%

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Auto meter report: watt

A watt value that an energy value must be different compared to a previous sent value before an unsolicited meter report is sent. Minimum value = 5 watt Maximum value = 255 watt

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Auto meter report: time

A time value that has to be passed compared to a previous sent value before a unsolicited meter report is sent. Minimum value = 10 seconds Maximum value = 255 seconds

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Last known status

What to do with lamp status when power applied. If 0x00: Always switch light off when power applied. If > 0x00: Switch lamp on/off depending on last known lampstatus before power was disconnected.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Fading down speed

The speed of fading down when activated (manual and RF). Fade speed is 1% per value (* 10 ms)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The plugInDimmer supports 2 association groups.

Group 1: Group 1

Receives BASIC SET commands

Association group 1 supports 8 nodes.

Group 2: Group 2

Receives METER and MULTILEVEL_SWITCH commands

Association group 2 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_METER_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1