Skip to content

Latest commit

 

History

History
297 lines (162 loc) · 9.26 KB

a803n_0_0.md

File metadata and controls

297 lines (162 loc) · 9.26 KB
layout title
documentation
A803N - ZWave

{% include base.html %}

A803N Motion Sensor

This describes the Z-Wave device A803N, manufactured by Cloud Media with the thing type UID of cloud_a803n_00_000.

A803N product image

The A803N supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The A803N does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Wakeup Information

The A803N does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Channels

The following table summarises the channels available for the A803N -:

Channel Channel Id Category Item Type
Binary Sensor sensor_binary Door Switch
Sensor (luminance) sensor_luminance Number
Alarm (general) alarm_general Door Switch
Battery Level battery-level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (luminance)

Indicates the current light reading.

The sensor_luminance channel supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Alarm (general)

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the A803N. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Param 1 Param 1
2 Param 2 Param 2
3 Param 3 Param 3
4 Param 4 Param 4
5 Param 5 Param 5
6 Param 6 Param 6
7 Param 7 Param 7
8 Param 8 Param 8
9 Param 9 Param 9
10 Param 10 Param 10
11 Param 11 Param 11
12 Param 12 Param 12
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 1: Param 1

Param 1

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Param 2

Param 2

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Param 3

Param 3

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Param 4

Param 4

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 15.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Param 5

Param 5

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Param 6

Param 6

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Param 7

Param 7

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Param 8

Param 8

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Param 9

Param 9

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Param 10

Param 10

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Param 11

Param 11

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Param 12

Param 12

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The A803N supports 4 association groups.

Group 1: Group 1

Association group 1 supports 1 node.

Group 2: Group 2

Association group 2 supports 4 nodes.

Group 3: Group 3

Association group 3 supports 4 nodes.

Group 4: Group 4

Association group 4 supports 4 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.