Skip to content

Latest commit

 

History

History
403 lines (258 loc) · 15.8 KB

mt2652_0_0.md

File metadata and controls

403 lines (258 loc) · 15.8 KB
layout title
documentation
MT2652 - ZWave

{% include base.html %}

MT2652 Scene Switch

This describes the Z-Wave device MT2652, manufactured by Devolo with the thing type UID of devolo_mt2652_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

MT2652 product image

The MT2652 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The MT2652 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The Home Control Wall Switch lets you control your Home Control devices at the press of a button. It has two
different rocker switches.

Inclusion Information

Activate inclusion on the device by pressing any one of the four buttons for one second.

Exclusion Information

Activate exclusion on the device by pressing any one of the four buttons for one second.

Wakeup Information

The MT2652 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Click button 2 in management mode.

Channels

The following table summarises the channels available for the MT2652 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number Number
Battery Level battery-level Battery Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the MT2652. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Button 1 and 3 pair mode Button 1 and 3 pair mode
2 Button 2 and 4 pair mode Button 2 and 4 pair mode
11 Command to control Group A Command sent to devices of control group A
12 Command to control Group B Command sent to devices of control group B
13 Command to control Group C Command sent to devices of control group C
14 Command to control Group D Command sent to devices of control group D
21 Send the following Switch All commands
22 Invert buttons
25 Block wake up even when Wake Up Interval is set
30 Send unsolicited Battery Report on Wake Up
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications
Lock Timeout Sets the time after which the door will auto lock

Parameter 1: Button 1 and 3 pair mode

Button 1 and 3 pair mode In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group 1, double click with group 3. The following option values may be configured -:

Value Description
0 Separately
1 In pair without double clicks
2 In pair with double clicks

The manufacturer defined default value is 1 (In pair without double clicks).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Button 2 and 4 pair mode

Button 2 and 4 pair mode In separate mode button 2 works with group 2, button 4 with groups 4. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group 2, double click with group 4. The following option values may be configured -:

Value Description
0 Separately
1 In pair without double clicks
2 In pair with double clicks

The manufacturer defined default value is 1 (In pair without double clicks).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 11: Command to control Group A

Command sent to devices of control group A Defines the command to be sent to devices of control group A when the related button is pressed.

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop The following option values may be configured -:

Value Description
0 Disabled
1 Switch On/Off/Dim (Basic Set/Switch Multilevel)
2 Switch On/Off only (send Basic Set)
3 Switch all
4 Send Scenes
5 Send Preconfigured Scenes
6 Control devices in proximity
7 Control door lock
8 Central scene to gateway (default)

The manufacturer defined default value is 8 (Central scene to gateway (default)).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Command to control Group B

Command sent to devices of control group B Defines the command to be sent to devices of control group B when the related button is pressed.

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop The following option values may be configured -:

Value Description
0 Disabled
1 Switch On/Off/Dim (Basic/Switch Multilevel)
2 Switch On/Off only (send Basic Set)
3 Switch all
4 Send Scenes
5 Send Preconfigured Scenes
6 Control devices in proximity
7 Control door lock
8 Central scene to gateway (default)

The manufacturer defined default value is 8 (Central scene to gateway (default)).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Command to control Group C

Command sent to devices of control group C Defines the command to be sent to devices of control group C when the related button is pressed.

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop The following option values may be configured -:

Value Description
0 Disabled
1 Switch On/Off/Dim (Basic/Switch Multilevel)
2 Switch On/Off only (send Basic Set)
3 Switch all
4 Send Scenes
5 Send Preconfigured Scenes
6 Control devices in proximity
7 Control door lock
8 Central scene to gateway (default)

The manufacturer defined default value is 8 (Central scene to gateway (default)).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Command to control Group D

Command sent to devices of control group D Defines the command to be sent to devices of control group D when the related button is pressed.

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop The following option values may be configured -:

Value Description
0 Disabled
1 Switch On/Off/Dim (Basic/Switch Multilevel)
2 Switch On/Off only (send Basic Set)
3 Switch all
4 Send Scenes
5 Send Preconfigured Scenes
6 Control devices in proximity
7 Control door lock
8 Central scene to gateway (default)

The manufacturer defined default value is 8 (Central scene to gateway (default)).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 21: Send the following Switch All commands

The following option values may be configured -:

Value Description
1 Switch off only (default)
2 Switch on only
255 Switch all on and off

The manufacturer defined default value is 1 (Switch off only (default)).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 22: Invert buttons

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_22_1 and is of type INTEGER.

Parameter 25: Block wake up even when Wake Up Interval is set

The following option values may be configured -:

Value Description
0 Wake up is blocked
1 Wakeup is not blocked (Default)

The manufacturer defined default value is 1 (Wakeup is not blocked (Default)).

This parameter has the configuration ID config_25_1 and is of type INTEGER.

Parameter 30: Send unsolicited Battery Report on Wake Up

The following option values may be configured -:

Value Description
0 No
1 To same node as wake up notification
2 Broadcast to neighbours

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MT2652 supports 5 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline

Association group 1 supports 10 nodes.

Group 2: Control Group A

Control Group A, controlled by button 1 or single clicks of buttons 1 and 3 Control Group A, controlled by button 1 or single clicks of buttons 1

Association group 2 supports 10 nodes.

Group 3: Control Group B

Control Group B, controlled by button 2 or single clicks of buttons 2 and 4

Association group 3 supports 10 nodes.

Group 4: Control Group C

Control Group C, controlled by button 3 or double clicks of buttons 1 and 3

Association group 4 supports 10 nodes.

Group 5: Control Group D

Control Group D, controlled by button 4 or double clicks of buttons 2 and 4

Association group 5 supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_CONTROLLER_CONF_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1
COMMAND_CLASS_MULTI_CMD_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.