MT02755 - ZWave

{% include base.html %}

MT02755 Humidity Sensor

This describes the Z-Wave device MT02755, manufactured by Devolo with the thing type UID of devolo_mt2755_00_000.

The device is in the category of Door, defining Door sensors.

MT02755 product image

The MT02755 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The MT02755 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The multisensor MT02755 has temperature and humidity function in one, based on Z-WaveTM technology.

Inclusion Information

There are one tamper keys in the back side of the device, It can add, remove, reset or association from the Z-WaveTM network.

In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the add mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.

  1. Have Z-WaveTM Controller entered inclusion mode.
  2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.
  3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.

Exclusion Information

Exclude/Remove:

  1. Have Z-WaveTM Controller entered exclusion mode.
  2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. Node ID has been excluded. 

Reset:

Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.

  1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.

  2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. 

  3. IDs are excluded and all settings will reset to factory default. 

Wakeup Information

The MT02755 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Press the tamper button on the back side

Channels

The following table summarises the channels available for the MT02755 -:

Channel Channel Id Category Item Type
Binary Sensor sensor_binary Door Switch
Sensor (relative humidity) sensor_relhumidity Humidity Number
Sensor (temperature) sensor_temperature Temperature Number:Temperature
Alarm (burglar) alarm_burglar Door Switch
Battery Level battery-level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number:Temperature item and is in the Temperature category.

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the MT02755. Detailed information on each parameter can be found in the sections below.

Param Name Description
5 Operation Mode Setting the temperature scale
6 Multi Sensor Function Switch Disable the humidity report after event triggered
7 Customer Function Notification Type
7 Customer Function Disable Multi CC in auto report
10 Auto Report Battery Time The interval time for auto report the battery level.
13 Auto Report Temperature Time The interval time for auto report the temperature.
14 Auto Report Humidity Time The interval time for auto report the humidity
20 Auto Report Tick Interval The interval time for auto report each tick
21 Temperature Differential Report The temperature differential to report
23 Humidity Differential Report The humidity differential to report.
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 5: Operation Mode

Setting the temperature scale Setting the temperature scale: 0: Fahrenheit, 1:Celsius The following option values may be configured -:

Value Description
0 Fahrenheit
8 Celsius

The manufacturer defined default value is 0 (Fahrenheit).

This parameter has the configuration ID config_5_1_00000008 and is of type INTEGER.

Parameter 6: Multi Sensor Function Switch

Disable the humidity report after event triggered Disable the humidity report after event triggered. (1:Disable, 0:Enable)  The following option values may be configured -:

Value Description
0 Enable
32 Disable

The manufacturer defined default value is 0 (Enable).

This parameter has the configuration ID config_6_1_00000020 and is of type INTEGER.

Parameter 7: Customer Function

Notification Type Notification Type:
0: Using Notification Report. 1: Using Sensor Binary Report.  The following option values may be configured -:

Value Description
0 Using Notification Report
16 Using Sensor Binary Report

The manufacturer defined default value is 0 (Using Notification Report).

This parameter has the configuration ID config_7_1_00000010 and is of type INTEGER.

Parameter 7: Customer Function

Disable Multi CC in auto report Disable Multi CC in auto report. (1:Disable, 0:Enable)  The following option values may be configured -:

Value Description
0 Enable
32 Disable

The manufacturer defined default value is 0 (Enable).

This parameter has the configuration ID config_7_1_00000020 and is of type INTEGER.

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level. The interval time for auto report the battery level.
0 means turn off auto report.
The default value is 12. The tick time can setting by the configuration No.20.  Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 13: Auto Report Temperature Time

The interval time for auto report the temperature. The interval time for auto report the temperature.
0 means turn off auto report.
The default value is 12. The tick time can setting by the configuration No.20.  Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Auto Report Humidity Time

The interval time for auto report the humidity The interval time for auto report the humidity.
0 means turn off auto report.
The default value is 12. The tick time can setting by the configuration No.20.  Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.

Units of one minute.
Caution1: Setting to 0 means turn off all auto report function.

Caution2: The value is unsigned byte  Values in the range 0 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: Temperature Differential Report

The temperature differential to report The temperature differential to report. 0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will detect every 10 seconds.

And when the temperature is over 140 degree Fahrenheit, it will continue report.  Values in the range 0 to 127 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 23: Humidity Differential Report

The humidity differential to report. The humidity differential to report. 0 means turn off this function. The unit is percentage.
Enable this function the device will detect every 10 seconds.  Values in the range 0 to 60 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_23_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MT02755 supports 1 association group.

Group 1: Receiving Report Message

Group 1 is for receiving the report message, like triggered event, temperature, humidity 

Association group 1 supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CMD_V1
COMMAND_CLASS_SECURITY_V1