layout | title |
---|---|
documentation |
MT02755 - ZWave |
{% include base.html %}
This describes the Z-Wave device MT02755, manufactured by Devolo with the thing type UID of devolo_mt2755_00_000
.
The device is in the category of Door, defining Door sensors.
The MT02755 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The MT02755 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The multisensor MT02755 has temperature and humidity function in one, based on Z-WaveTM technology.
There are one tamper keys in the back side of the device, It can add, remove, reset or association from the Z-WaveTM network.
In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the add mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.
- Have Z-WaveTM Controller entered inclusion mode.
- Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.
- After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
Exclude/Remove:
- Have Z-WaveTM Controller entered exclusion mode.
- Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. Node ID has been excluded.
Reset:
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
-
Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
-
After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
-
IDs are excluded and all settings will reset to factory default.
The MT02755 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Press the tamper button on the back side
The following table summarises the channels available for the MT02755 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Binary Sensor | sensor_binary | Door | Switch |
Sensor (relative humidity) | sensor_relhumidity | Humidity | Number |
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Alarm (burglar) | alarm_burglar | Door | Switch |
Battery Level | battery-level | Battery | Number |
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the current relative humidity.
The sensor_relhumidity
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 10 configuration parameters available in the MT02755. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
5 | Operation Mode | Setting the temperature scale |
6 | Multi Sensor Function Switch | Disable the humidity report after event triggered |
7 | Customer Function | Notification Type |
7 | Customer Function | Disable Multi CC in auto report |
10 | Auto Report Battery Time | The interval time for auto report the battery level. |
13 | Auto Report Temperature Time | The interval time for auto report the temperature. |
14 | Auto Report Humidity Time | The interval time for auto report the humidity |
20 | Auto Report Tick Interval | The interval time for auto report each tick |
21 | Temperature Differential Report | The temperature differential to report |
23 | Humidity Differential Report | The humidity differential to report. |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Setting the temperature scale Setting the temperature scale: 0: Fahrenheit, 1:Celsius The following option values may be configured -:
Value | Description |
---|---|
0 | Fahrenheit |
8 | Celsius |
The manufacturer defined default value is 0
(Fahrenheit).
This parameter has the configuration ID config_5_1_00000008
and is of type INTEGER
.
Disable the humidity report after event triggered Disable the humidity report after event triggered. (1:Disable, 0:Enable) The following option values may be configured -:
Value | Description |
---|---|
0 | Enable |
32 | Disable |
The manufacturer defined default value is 0
(Enable).
This parameter has the configuration ID config_6_1_00000020
and is of type INTEGER
.
Notification Type
Notification Type:
0: Using Notification Report. 1: Using Sensor Binary Report.
The following option values may be configured -:
Value | Description |
---|---|
0 | Using Notification Report |
16 | Using Sensor Binary Report |
The manufacturer defined default value is 0
(Using Notification Report).
This parameter has the configuration ID config_7_1_00000010
and is of type INTEGER
.
Disable Multi CC in auto report Disable Multi CC in auto report. (1:Disable, 0:Enable) The following option values may be configured -:
Value | Description |
---|---|
0 | Enable |
32 | Disable |
The manufacturer defined default value is 0
(Enable).
This parameter has the configuration ID config_7_1_00000020
and is of type INTEGER
.
The interval time for auto report the battery level.
The interval time for auto report the battery level.
0 means turn off auto report.
The default value is 12. The tick time can setting by the configuration No.20.
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
The interval time for auto report the temperature.
The interval time for auto report the temperature.
0 means turn off auto report.
The default value is 12. The tick time can setting by the configuration No.20.
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
The interval time for auto report the humidity
The interval time for auto report the humidity.
0 means turn off auto report.
The default value is 12. The tick time can setting by the configuration No.20.
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
The interval time for auto report each tick Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.
Units of one minute.
Caution1: Setting to 0 means turn off all auto report function.
Caution2: The value is unsigned byte Values in the range 0 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
The temperature differential to report
The temperature differential to report. 0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will detect every 10 seconds.
And when the temperature is over 140 degree Fahrenheit, it will continue report. Values in the range 0 to 127 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
The humidity differential to report.
The humidity differential to report. 0 means turn off this function. The unit is percentage.
Enable this function the device will detect every 10 seconds.
Values in the range 0 to 60 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The MT02755 supports 1 association group.
Group 1 is for receiving the report message, like triggered event, temperature, humidity
Association group 1 supports 8 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V2 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CMD_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.