layout | title |
---|---|
documentation |
ph-pse02 - ZWave |
{% include base.html %}
This describes the Z-Wave device ph-pse02, manufactured by Devolo with the thing type UID of devolo_phpse02_00_000
.
The device is in the category of Siren, defining Siren used by Alarm systems.
The ph-pse02 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
### NOTE ###
The XML used for adding this device to the database comes from the Devolo Home Control Alarmsiren (http://www.devolo.de/article/devolo-home-control-alarmsirene/). But it seems to be made by Zipato (https://www.zipato.com/product/multisound-indoor-siren).
### FEATURES ###
- Indoor multichannel siren that works with a a variety of Z-Wave networks/controllers, regardless of the manufacturer
- The new Z-Wave 500 series chip supports multichannel operationand higher data rates (9.6/40/100kbps)
- 110db sound level
- 6 sounds: Door Chime, Bi Bi Arm/Disarm, Intruder alarm, Ambulance, Police car
- Higher output power enhances communication range(+6dBm output power as compared to -2.5dBm 300 series)
- DC or Li-ion battery power (over 24 hours of battery life)
- Battery overcharge protection
- Very low power consumption
- Over-the-air firmware update
- Easy to install in EU/China/Taiwan wall sockets
- Tamperproof protection
### TECHNICAL SPECIFICATIONS ###
PROTOCOL: Z-Wave Plus
POWER
- DC 5V, Li-Ion battery (optional)
- BATTERY CAPACITY 1150mAh
OPERATING CONDITIONS:
- OPERATING VOLTAGE 3.7V
- OPERATING CURRENT 150 mA
- OPERATION TEMPERATURE -10°C ~ 40°C
RANGE
- Minimum 30 meters indoor
- 70 meters outdoor (meant for indoor use only)
DIMENSIONS
- DEVICE DIMENSIONS 110 x 110 x 22 mm
- DEVICE WEIGHT 113g
- PACKAGE DIMENSIONS 117 x 50 x 117 mm
- PACKAGE WEIGHT 217g
FREQUENCY
ph-pse02.au 921.42 MHz (AU)
ph-pse02.eu 868.42 MHz (EU)
ph-pse02.in 865.20 MHz (IN)
ph-pse02.is 916.02 MHz (IS)
ph-pse02.ru 869.02 MHz (RU)
ph-pse02.us 908.42 MHz (US)
Source: https://www.zipato.com/product/multisound-indoor-siren
The following table summarises the channels available for the ph-pse02 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Binary Sensor | sensor_binary | Door | Switch |
Alarm (burglar) | alarm_burglar | Door | Switch |
Alarm (general) | alarm_general | Door | Switch |
Start Sound | notification_send | Number |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
<td>
<p>
Notification
</p>
</td>
<td>
<p>
Event
</p>
</td>
<td>
<p>
Sound
</p>
</td>
<td>
<p>
Smokealarm (0x01)
</p>
</td>
<td>
<p>
0x01 ~ 0xFF
</p>
</td>
<td>
<p>
fire alert
</p>
</td>
<td>
<p>
Accesscontrol (0x06)
</p>
</td>
<td>
<p>
Window/Door open (0x16)
</p>
</td>
<td>
<p>
door chime
</p>
</td>
<td>
<p>
Accesscontrol (0x06)
</p>
</td>
<td>
<p>
Activate alarm system (0x03)
</p>
</td>
<td>
<p>
2x beep
</p>
</td>
<td>
<p>
Accesscontrol (0x06)
</p>
</td>
<td>
<p>
Deactivate alarm system (0x04)
</p>
</td>
<td>
<p>
1x beep
</p>
</td>
<td>
<p>
Homesecurity (0x07)
</p>
</td>
<td>
<p>
0x01 ~ 0xFF
</p>
</td>
<td>
<p>
emergency
</p> sound
</td>
<td>
<p>
Emergency (0x0A)
</p>
</td>
<td>
<p>
Contact police (0x01)
</p>
</td>
<td>
<p>
policecar
</p>
<p>
sound
</p>
</td>
<td>
<p>
Emergency (0x0A)
</p>
</td>
<td>
<p>
Contact fire department (0x02)
</p>
</td>
<td>
<p>
fire engine sound
</p>
</td>
<td>
<p>
Emergency (0x0A)
</p>
</td>
<td>
<p>
Contact ambulance (0x03)
</p>
</td>
<td>
<p>
ambulance
</p>
<p>
sound
</p>
</td>
<td>
Emergency (0x0A)
</td>
<td>
<p>
Notification (0xFE)
</p>
</td>
<td>
<p>
silent alarm (no sound, flashing LED)
</p>
</td>
event1 |
event2 |
event7 |
event8 |
event3 |
event4 |
event5 |
event6 |
event9 |
Sends a notification.
The notification_send
channel supports the Number
item.
The following table provides a summary of the 3 configuration parameters available in the ph-pse02. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
7 | Costumer Function | NotificationReport/BinaryReport |
29 | Disable Alarm | Disable the alarm function. |
31 | Alarm Duration | Play alarm sound duration. |
NotificationReport/BinaryReport Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_7_4
and is of type INTEGER
.
Disable the alarm function. Disable the alarm function.
1: Disable Alarm,
0: Enable Alarm.
Caution: After the power up, this configuration is always 0. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_29_4
and is of type INTEGER
.
Play alarm sound duration. Play alarm sound duration, 1 tick is 30 seconds.
Default is 3 minutes, maximum is 63.5 minutes.
0 means never auto stop. Values in the range 0 to 127 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_31_4_0000000C
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ph-pse02 supports 1 association group.
Report Message, e.g. tamper alarm Notice: The device supports 1 group.
The group 1 is for receiving the report message, like tamper event. And the group 8 nodes maximum
Association group 1 supports 8 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V2 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.