layout title
documentation
DCH-Z110 - ZWave

{% include base.html %}

DCH-Z110 Door & Window Sensor

This describes the Z-Wave device DCH-Z110, manufactured by D-Link with the thing type UID of dlink_dchz110_00_000.

The device is in the category of Door, defining Door sensors.

DCH-Z110 product image

The DCH-Z110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The DCH-Z110 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Wakeup Information

The DCH-Z110 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Channels

The following table summarises the channels available for the DCH-Z110 -:

Channel Channel Id Category Item Type
Door / Window Status sensor_door Door Contact
Sensor (luminance) sensor_luminance Number
Sensor (temperature) sensor_temperature Temperature Number:Temperature
Alarm alarm_general Door Switch
Battery Level battery-level Battery Number

Door / Window Status

Indicates if the door/window is open or closed.

The sensor_door channel supports the Contact item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Contact item type -:

Value Label
OPEN Open
CLOSED Closed

Sensor (luminance)

Indicates the current light reading.

The sensor_luminance channel supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number:Temperature item and is in the Temperature category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 19 configuration parameters available in the DCH-Z110. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Basic Set Level Setting the BASIC command value to turn on the light.
3 PIR Sensitivity Set the sensitivity for the PIR (Passive Infrared Sensor).
4 Light Threshold Set the illumination threshold to turn on the light.
5 Operation Mode Parameter to set the Operation Mode. Bit 0: Reserved. Bit 1: 1 means enable test mode; 0 means normal mode. Notice: Ignored if DIP Switch is not set to Customer Mode. Bit 2: Disable the door/window function. 1
6 Multi-Sensor Function Switch Parameter to set the sensor functions.
  • Bit 0: Disable magnetic integrate illumination to turn on the lighting nodes in the association group 2. 1: Disable, 0: Enable

  • Bit 1: Disable PIR integrate Illumination to turn on the | | 7 | Customer Function | Parameter to set the Customer Function. | | 7 | Disable send of BASIC OFF after door closed | | | 7 | Notification Type | | | 7 | Disable Multi CC in auto report | | | 7 | Disable to report battery state when the device triggered | | | 8 | PIR Re-Detect Interval Time | In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default is 3 (24 seconds).

  • 1 - 127 = Number of ticks. 8 seconds per tick, default value is 3 (24 seconds). | | 9 | Turn Off Light Time | After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected.

  • 0 = Never send turn off light command.

  • 1 - 127 = Number of ticks. 8 seconds per tick, default value is 4 (32 seconds | | 10 | Auto Report Battery Time | The interval time for auto reporting the battery level.

  • 0 = Turn off auto report battery.

  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 11 | Auto Report Door/Window State Time | The interval time for auto reporting the door/window state.

  • 0 = Turn off auto report door/window state.

  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 12 | Auto Report Illumination Time | The Interval time for auto reporting the illumination state.
    0 = Turn off auto report illumination. 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 13 | Auto Report Temperature Time | The interval time for auto reporting the temperature state.

  • 0 = Turn off auto report temperature.

  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 20 | Auto Report Tick Interval | The interval time for each auto report tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. 0 = Turn off all auto report functions. 1-255 = Interval time for each tick. Default is 30. Unit is in minutes | | 21 | Temperature Differential Report | The temperature differential to report. The unit is Fahrenheit. When enabled, the device will measure the temperature every minute and when the temperature is over 140 degree Fahrenheit, it will continuesly report. Enabling this functionality will cause s | | 22 | Illumination Differential Report | The illumination differential to report. The unit is percentage. When enabled, the device will measure every minute. Enabling this functionality will cause some issue. Please check the “Illumination Report” section of the Multisensor manual. | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light.

  • 0: Turn off the light.
  • 1 - 100: For dimmers 1 to 100 means the light level.
  • 255: Turns on the light. (Default)  The following option values may be configured, in addition to values in the range 0 to 100 -:
Value Description
0 Off
255 On

The manufacturer defined default value is 255 (On).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: PIR Sensitivity

Set the sensitivity for the PIR (Passive Infrared Sensor).

  • 0 = Disable the PIR motion detection.
  • 1 - 99 = 1 means the lowest sensitivity, 99 means the highest sensitivity

High sensitivity means de The following option values may be configured, in addition to values in the range 0 to 99 -:

Value Description
0 Disable

The manufacturer defined default value is 70.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Light Threshold

Set the illumination threshold to turn on the light. When the event triggers and the environment illumination is lower than the threshold, the device will turn on the light.

  • 0 = Turn off illumination detected function and never turn The following option values may be configured, in addition to values in the range 0 to 100 -:
Value Description
0 Disable

The manufacturer defined default value is 100.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Operation Mode

Parameter to set the Operation Mode. Bit 0: Reserved. Bit 1: 1 means enable test mode; 0 means normal mode. Notice: Ignored if DIP Switch is not set to Customer Mode. Bit 2: Disable the door/window function. 1

The following option values may be configured, in addition to values in the range 0 to 127 -:

Value Description
10 Preset: Celsius and LED on = Bits: 00001010 = 10

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Multi-Sensor Function Switch

Parameter to set the sensor functions.

  • Bit 0: Disable magnetic integrate illumination to turn on the lighting nodes in the association group 2. 1: Disable, 0: Enable
  • Bit 1: Disable PIR integrate Illumination to turn on the

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Customer Function

Parameter to set the Customer Function. lThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 127 -:

Value Description
20 Preset: PIR Super Sensitivity and Binary Report = Bits: 00010100 = 20

The manufacturer defined default value is 4.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 7: Disable send of BASIC OFF after door closed

The following option values may be configured -:

Value Description
0 Enable
1 Disable

The manufacturer defined default value is 1 (Disable).

This parameter has the configuration ID config_7_1_00000008 and is of type INTEGER.

Parameter 7: Notification Type

The following option values may be configured -:

Value Description
0 Notification Report
1 Sensor Binary Report

The manufacturer defined default value is 0 (Notification Report).

This parameter has the configuration ID config_7_1_00000010 and is of type INTEGER.

Parameter 7: Disable Multi CC in auto report

The following option values may be configured -:

Value Description
0 Enable
1 Disable

The manufacturer defined default value is 0 (Enable).

This parameter has the configuration ID config_7_1_00000020 and is of type INTEGER.

Parameter 7: Disable to report battery state when the device triggered

The following option values may be configured -:

Value Description
0 Enable
1 Disable

The manufacturer defined default value is 0 (Enable).

This parameter has the configuration ID config_7_1_00000040 and is of type INTEGER.

Parameter 8: PIR Re-Detect Interval Time

In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default is 3 (24 seconds).

  • 1 - 127 = Number of ticks. 8 seconds per tick, default value is 3 (24 seconds).

Values in the range 1 to 127 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Turn Off Light Time

After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected.

  • 0 = Never send turn off light command.
  • 1 - 127 = Number of ticks. 8 seconds per tick, default value is 4 (32 seconds

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Auto Report Battery Time

The interval time for auto reporting the battery level.

  • 0 = Turn off auto report battery.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Auto Report Door/Window State Time

The interval time for auto reporting the door/window state.

  • 0 = Turn off auto report door/window state.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Auto Report Illumination Time

The Interval time for auto reporting the illumination state.
0 = Turn off auto report illumination. 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.

Values in the range 1 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Auto Report Temperature Time

The interval time for auto reporting the temperature state.

  • 0 = Turn off auto report temperature.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.

Values in the range 1 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 20: Auto Report Tick Interval

The interval time for each auto report tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. 0 = Turn off all auto report functions. 1-255 = Interval time for each tick. Default is 30. Unit is in minutes

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: Temperature Differential Report

The temperature differential to report. The unit is Fahrenheit. When enabled, the device will measure the temperature every minute and when the temperature is over 140 degree Fahrenheit, it will continuesly report. Enabling this functionality will cause s

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 22: Illumination Differential Report

The illumination differential to report. The unit is percentage. When enabled, the device will measure every minute. Enabling this functionality will cause some issue. Please check the “Illumination Report” section of the Multisensor manual.

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_22_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DCH-Z110 supports 2 association groups.

Group 1: Reports

Association group 1 supports 8 nodes.

Group 2: Light Control

Association group 2 supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CMD_V1
COMMAND_CLASS_SECURITY_V1