layout | title |
---|---|
documentation |
DCH-Z110 - ZWave |
{% include base.html %}
This describes the Z-Wave device DCH-Z110, manufactured by D-Link with the thing type UID of dlink_dchz110_00_000
.
The device is in the category of Door, defining Door sensors.
The DCH-Z110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The DCH-Z110 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The DCH-Z110 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The following table summarises the channels available for the DCH-Z110 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Door / Window Status | sensor_door | Door | Contact |
Sensor (luminance) | sensor_luminance | Number | |
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Alarm | alarm_general | Door | Switch |
Battery Level | battery-level | Battery | Number |
Indicates if the door/window is open or closed.
The sensor_door
channel supports the Contact
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Contact
item type -:
Value | Label |
---|---|
OPEN | Open |
CLOSED | Closed |
Indicates the current light reading.
The sensor_luminance
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 19 configuration parameters available in the DCH-Z110. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | Basic Set Level | Setting the BASIC command value to turn on the light. |
3 | PIR Sensitivity | Set the sensitivity for the PIR (Passive Infrared Sensor). |
4 | Light Threshold | Set the illumination threshold to turn on the light. |
5 | Operation Mode | Parameter to set the Operation Mode. Bit 0: Reserved. Bit 1: 1 means enable test mode; 0 means normal mode. Notice: Ignored if DIP Switch is not set to Customer Mode. Bit 2: Disable the door/window function. 1 |
6 | Multi-Sensor Function Switch | Parameter to set the sensor functions. |
-
Bit 0: Disable magnetic integrate illumination to turn on the lighting nodes in the association group 2. 1: Disable, 0: Enable
-
Bit 1: Disable PIR integrate Illumination to turn on the | | 7 | Customer Function | Parameter to set the Customer Function. | | 7 | Disable send of BASIC OFF after door closed | | | 7 | Notification Type | | | 7 | Disable Multi CC in auto report | | | 7 | Disable to report battery state when the device triggered | | | 8 | PIR Re-Detect Interval Time | In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default is 3 (24 seconds).
-
1 - 127 = Number of ticks. 8 seconds per tick, default value is 3 (24 seconds). | | 9 | Turn Off Light Time | After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected.
-
0 = Never send turn off light command.
-
1 - 127 = Number of ticks. 8 seconds per tick, default value is 4 (32 seconds | | 10 | Auto Report Battery Time | The interval time for auto reporting the battery level.
-
0 = Turn off auto report battery.
-
1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 11 | Auto Report Door/Window State Time | The interval time for auto reporting the door/window state.
-
0 = Turn off auto report door/window state.
-
1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 12 | Auto Report Illumination Time | The Interval time for auto reporting the illumination state.
0 = Turn off auto report illumination. 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 13 | Auto Report Temperature Time | The interval time for auto reporting the temperature state. -
0 = Turn off auto report temperature.
-
1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. | | 20 | Auto Report Tick Interval | The interval time for each auto report tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. 0 = Turn off all auto report functions. 1-255 = Interval time for each tick. Default is 30. Unit is in minutes | | 21 | Temperature Differential Report | The temperature differential to report. The unit is Fahrenheit. When enabled, the device will measure the temperature every minute and when the temperature is over 140 degree Fahrenheit, it will continuesly report. Enabling this functionality will cause s | | 22 | Illumination Differential Report | The illumination differential to report. The unit is percentage. When enabled, the device will measure every minute. Enabling this functionality will cause some issue. Please check the “Illumination Report” section of the Multisensor manual. | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Setting the BASIC command value to turn on the light.
- 0: Turn off the light.
- 1 - 100: For dimmers 1 to 100 means the light level.
- 255: Turns on the light. (Default) The following option values may be configured, in addition to values in the range 0 to 100 -:
Value | Description |
---|---|
0 | Off |
255 | On |
The manufacturer defined default value is 255
(On).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Set the sensitivity for the PIR (Passive Infrared Sensor).
- 0 = Disable the PIR motion detection.
- 1 - 99 = 1 means the lowest sensitivity, 99 means the highest sensitivity
High sensitivity means de The following option values may be configured, in addition to values in the range 0 to 99 -:
Value | Description |
---|---|
0 | Disable |
The manufacturer defined default value is 70
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Set the illumination threshold to turn on the light. When the event triggers and the environment illumination is lower than the threshold, the device will turn on the light.
- 0 = Turn off illumination detected function and never turn The following option values may be configured, in addition to values in the range 0 to 100 -:
Value | Description |
---|---|
0 | Disable |
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter to set the Operation Mode. Bit 0: Reserved. Bit 1: 1 means enable test mode; 0 means normal mode. Notice: Ignored if DIP Switch is not set to Customer Mode. Bit 2: Disable the door/window function. 1
The following option values may be configured, in addition to values in the range 0 to 127 -:
Value | Description |
---|---|
10 | Preset: Celsius and LED on = Bits: 00001010 = 10 |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter to set the sensor functions.
- Bit 0: Disable magnetic integrate illumination to turn on the lighting nodes in the association group 2. 1: Disable, 0: Enable
- Bit 1: Disable PIR integrate Illumination to turn on the
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter to set the Customer Function. lThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 127 -:
Value | Description |
---|---|
20 | Preset: PIR Super Sensitivity and Binary Report = Bits: 00010100 = 20 |
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Enable |
1 | Disable |
The manufacturer defined default value is 1
(Disable).
This parameter has the configuration ID config_7_1_00000008
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Notification Report |
1 | Sensor Binary Report |
The manufacturer defined default value is 0
(Notification Report).
This parameter has the configuration ID config_7_1_00000010
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Enable |
1 | Disable |
The manufacturer defined default value is 0
(Enable).
This parameter has the configuration ID config_7_1_00000020
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Enable |
1 | Disable |
The manufacturer defined default value is 0
(Enable).
This parameter has the configuration ID config_7_1_00000040
and is of type INTEGER
.
In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default is 3 (24 seconds).
- 1 - 127 = Number of ticks. 8 seconds per tick, default value is 3 (24 seconds).
Values in the range 1 to 127 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected.
- 0 = Never send turn off light command.
- 1 - 127 = Number of ticks. 8 seconds per tick, default value is 4 (32 seconds
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
The interval time for auto reporting the battery level.
- 0 = Turn off auto report battery.
- 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
The interval time for auto reporting the door/window state.
- 0 = Turn off auto report door/window state.
- 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
The Interval time for auto reporting the illumination state.
0 = Turn off auto report illumination. 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Values in the range 1 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
The interval time for auto reporting the temperature state.
- 0 = Turn off auto report temperature.
- 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Values in the range 1 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
The interval time for each auto report tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. 0 = Turn off all auto report functions. 1-255 = Interval time for each tick. Default is 30. Unit is in minutes
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
The temperature differential to report. The unit is Fahrenheit. When enabled, the device will measure the temperature every minute and when the temperature is over 140 degree Fahrenheit, it will continuesly report. Enabling this functionality will cause s
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
The illumination differential to report. The unit is percentage. When enabled, the device will measure every minute. Enabling this functionality will cause some issue. Please check the “Illumination Report” section of the Multisensor manual.
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DCH-Z110 supports 2 association groups.
Association group 1 supports 8 nodes.
Association group 2 supports 8 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V2 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CMD_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.