Skip to content

Latest commit

 

History

History
411 lines (303 loc) · 7.69 KB

dchz510_0_0.md

File metadata and controls

411 lines (303 loc) · 7.69 KB
layout title
documentation
DCH-Z510 - ZWave

{% include base.html %}

DCH-Z510 Siren

This describes the Z-Wave device DCH-Z510, manufactured by D-Link with the thing type UID of dlink_dchz510_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

DCH-Z510 product image

The DCH-Z510 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The DCH-Z510 mydlink Z-Wave Siren is a wireless siren.

Inclusion Information

  1. Have Z-Wave Controller enter inclusion mode.
  2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.
  3. After add successful, the LED will light ON 1 second 

Exclusion Information

  1. Have Z-Wave Controller enter exclusion mode.
  2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
  3. Node ID has been excluded. 

Channels

The following table summarises the channels available for the DCH-Z510 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Binary Sensor sensor_binary Door Switch
Start sound notification_send Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Start sound

<td>
  <p>
    Notification
  </p>
</td>

<td>
  <p>
    Event
  </p>
</td>

<td>
  <p>
    Sound
  </p>
</td>
<td>
  <p>
    Smokealarm (0x01)
  </p>
</td>

<td>
  <p>
    0x01 ~ 0xFF
  </p>
</td>

<td>
  <p>
    fire alert       <br />
  </p>
</td>
<td>
  <p>
    Accesscontrol (0x06)
  </p>
</td>

<td>
  <p>
    Window/Door open (0x16)
  </p>
</td>

<td>
  <p>
    door chime
  </p>
</td>
<td>
  <p>
    Accesscontrol (0x06)
  </p>
</td>

<td>
  <p>
    Activate alarm system (0x03)
  </p>
</td>

<td>
  <p>
    2x beep
  </p>
</td>
<td>
  <p>
    Accesscontrol (0x06)
  </p>
</td>

<td>
  <p>
    Deactivate alarm system (0x04)
  </p>
</td>

<td>
  <p>
    1x beep
  </p>
</td>
<td>
  <p>
    Homesecurity (0x07)
  </p>
</td>

<td>
  <p>
    0x01 ~ 0xFF
  </p>
</td>

<td>
  <p>
    emergency sound
  </p>
</td>
<td>
  <p>
    Emergency (0x0A)
  </p>
</td>

<td>
  <p>
    Contact police (0x01)
  </p>
</td>

<td>
  <p>
    policecar sound
  </p>
</td>
<td>
  <p>
    Emergency (0x0A)
  </p>
</td>

<td>
  <p>
    Contact fire department (0x02)
  </p>
</td>

<td>
  <p>
    fire engine sound<br />
  </p>
</td>
<td>
  <p>
    Emergency (0x0A)
  </p>
</td>

<td>
  <p>
    Contact ambulance (0x03)
  </p>
</td>

<td>
  <p>
    ambulance
  </p>
  
  <p>
    sound 
  </p>
</td>
<td>
  Emergency (0x0A)
</td>

<td>
  <p>
    Notification (0xFE)
  </p>
</td>

<td>
  <p>
    silent alarm (no sound,  flashing LED)                        <br />
  </p>
</td>
 
event1
event2
event7
event8
event3
event4
event5
event6
event9

Sends a notification.

The notification_send channel supports the Number item.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the DCH-Z510. Detailed information on each parameter can be found in the sections below.

Param Name Description
7 Customer Function
29 Disable Alarm
31 Alarm Duration Play alarm sound duration, 1 tick is 30 seconds. 0 means never auto stop.

Parameter 7: Customer Function

The following option values may be configured -:

Value Description
0 Using Notification Report
16 Using Sensor Binary Report

The manufacturer defined default value is 0 (Using Notification Report).

This parameter has the configuration ID config_7_1_00000010 and is of type INTEGER.

Parameter 29: Disable Alarm

The following option values may be configured -:

Value Description
0 Enable Alarm
1 Disable Alarm

The manufacturer defined default value is 0 (Enable Alarm).

This parameter has the configuration ID config_29_1 and is of type INTEGER.

Parameter 31: Alarm Duration

Play alarm sound duration, 1 tick is 30 seconds. 0 means never auto stop.

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_31_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DCH-Z510 supports 1 association group.

Group 1: Report Messages

The group 1 is for receiving the report message, like tamper event. This is the device's Lifeline group. The group supports 8 nodes maximum.

Association group 1 supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.