layout | title |
---|---|
documentation |
ZW15RM-PLUS - ZWave |
{% include base.html %}
This describes the Z-Wave device ZW15RM-PLUS, manufactured by Wenzhou MTLC Electric Appliances Co.,Ltd. with the thing type UID of enerwave_zw15rm_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The ZW15RM-PLUS supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Z-Wave Tamper Resistant Duplex Receptacle that monitors power and allows for Z-Wave control of the "bottom" outlet. The outlet is rated for 120VAC, 15A.
- Active "Inclusion Mode" on your controller.
- Press and hold the manual ON/OFF button on the receptacle for around 3 seconds.
- The primary controller will indicate the inclusion is successful.
- Active "Exclusion Mode" on your controller.
- Press and hold the manual ON/OFF button for 3 seconds.
- The blue LED indicator will blink, indicating exclusion was successful.
The following table summarises the channels available for the ZW15RM-PLUS -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Switch the power on and off.
The switch_binary
channel and is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh
channel and is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel and is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 1 configuration parameters available in the ZW15RM-PLUS. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | ON/OFF | Synchronization of outlet power and LED indicator |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Synchronization of outlet power and LED indicator This value only controls the bottom outlet, the top outlet is always on. The following option values may be configured -:
Value | Description |
---|---|
0 | Power on, LED off |
1 | Power on, LED on |
The manufacturer defined default value is 0
(Power on, LED off).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW15RM-PLUS supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Send device reset local notification
Association group 1 supports 1 node.
Send basic report
Association group 2 supports 5 nodes.
Send meter power report
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.