Skip to content

Latest commit

 

History

History
217 lines (129 loc) · 7.19 KB

zw20rm_0_0.md

File metadata and controls

217 lines (129 loc) · 7.19 KB
layout title
documentation
ZW20RM - ZWave

{% include base.html %}

ZW20RM In-wall Smart Meter Duplex Receptacle

This describes the Z-Wave device ZW20RM, manufactured by Wenzhou MTLC Electric Appliances Co.,Ltd. with the thing type UID of enerwave_zw20rm_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZW20RM product image

The ZW20RM supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZW20RM -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Sensor (power) sensor_power Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the ZW20RM. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Synchronization of load power and LED indicator Synchronization of load power and LED indicator
8 Instant Meter Autosend Interval Instant Energy Autosend Interval (send METER_REPORT)
9 Instant Sensor Autosend interval Instant Energy Autosend interval (send SENSOR_MULTILEVEL_REPORT)
10 Accumulated Meter Autosend Interval Accumulated Energy Autosend Interval report (send METER_REPORT)
11 Enable automatic notifications Enable automatic notifications to associated device
12 Minimum change to report Minimum change in wattage report
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Synchronization of load power and LED indicator

Synchronization of load power and LED indicator

The following option values may be configured -:

Value Description
0 Power on, LED off
1 Power on, LED on

The manufacturer defined default value is 0 (Power on, LED off).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 8: Instant Meter Autosend Interval

Instant Energy Autosend Interval (send METER_REPORT)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Instant Sensor Autosend interval

Instant Energy Autosend interval (send SENSOR_MULTILEVEL_REPORT)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Accumulated Meter Autosend Interval

Accumulated Energy Autosend Interval report (send METER_REPORT)

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Enable automatic notifications

Enable automatic notifications to associated device Device will send a notification whenever the is a wattage change The following option values may be configured -:

Value Description
0 Not report (METER_REPORT)
1 Send (METER_REPORT) only
2 Send (SENSOR_MULTI_LEVEL_REPORT) only
3 Send both

The manufacturer defined default value is 1 (Send (METER_REPORT) only).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Minimum change to report

Minimum change in wattage report 0-255: 0.0-25.5W Values in the range 0 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW20RM supports 3 association groups.

Group 1: Notifications

Lifeline

Association group 1 supports 1 node.

Group 2: StatusReport

Send basic report

Association group 2 supports 5 nodes.

Group 3: PowerReport

Send meter power report

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V2
COMMAND_CLASS_METER_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.