layout | title |
---|---|
documentation |
ZW20RM - ZWave |
{% include base.html %}
This describes the Z-Wave device ZW20RM, manufactured by Wenzhou MTLC Electric Appliances Co.,Ltd. with the thing type UID of enerwave_zw20rm_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The ZW20RM supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the ZW20RM -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Sensor (power) | sensor_power | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Indicates the energy consumption (kWh).
The sensor_power
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 6 configuration parameters available in the ZW20RM. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Synchronization of load power and LED indicator | Synchronization of load power and LED indicator |
8 | Instant Meter Autosend Interval | Instant Energy Autosend Interval (send METER_REPORT) |
9 | Instant Sensor Autosend interval | Instant Energy Autosend interval (send SENSOR_MULTILEVEL_REPORT) |
10 | Accumulated Meter Autosend Interval | Accumulated Energy Autosend Interval report (send METER_REPORT) |
11 | Enable automatic notifications | Enable automatic notifications to associated device |
12 | Minimum change to report | Minimum change in wattage report |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Synchronization of load power and LED indicator
The following option values may be configured -:
Value | Description |
---|---|
0 | Power on, LED off |
1 | Power on, LED on |
The manufacturer defined default value is 0
(Power on, LED off).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Instant Energy Autosend Interval (send METER_REPORT)
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Instant Energy Autosend interval (send SENSOR_MULTILEVEL_REPORT)
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Accumulated Energy Autosend Interval report (send METER_REPORT)
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Enable automatic notifications to associated device Device will send a notification whenever the is a wattage change The following option values may be configured -:
Value | Description |
---|---|
0 | Not report (METER_REPORT) |
1 | Send (METER_REPORT) only |
2 | Send (SENSOR_MULTI_LEVEL_REPORT) only |
3 | Send both |
The manufacturer defined default value is 1
(Send (METER_REPORT) only).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Minimum change in wattage report 0-255: 0.0-25.5W Values in the range 0 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW20RM supports 3 association groups.
Lifeline
Association group 1 supports 1 node.
Send basic report
Association group 2 supports 5 nodes.
Send meter power report
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |