This describes the Z-Wave device FGD211, manufactured by Fibargroup with the thing type UID of fibaro_fgd211_01_009
.
This version of the device is limited to firmware version 1.9
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The FGD211 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Remotely controlled Dimmer is designed to operate with or without neutral lead. It may be used as a switch in systems without neutral lead.
The Dimmer enters the mode of inclusion after quick pressing three times the push-button connected to S1 terminal or push-button B located inside the housing.
The Dimmer enters the mode of exclusion after quick pressing three times the push-button connected to S1 terminal or push-button B located inside the housing.
The following table summarises the channels available for the FGD211 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Updating the dimming level without switch | config_decimal | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Generic class for configuration parameter.
The config_decimal
channel supports the Number
item.
The following table provides a summary of the 20 configuration parameters available in the FGD211. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Enable/Disable ALL ON/OFF | Activate/Deactive ALL ON/OFF |
6 | Separation of association sending (key 1) | Activate/Deactivate association sending for group 1 - Also see param #16 |
7 | Control key #2 behaviour | Key no.2 is not represented by any physical device |
8 | Dimming step at automatic control | |
9 | Time of MANUALLY moving between dimming values | Options for changing parameter 1-255 (10ms - 2,5s) |
10 | Time of AUTOMATIC moving between dimming values | Options for changing parameter 1-255 |
11 | Dimming step at manual control | Options for changing parameter 1-99 |
12 | Maximum dimmer level control | Options for changing parameter 2-99 |
13 | Minimum dimmer level control | Options for changing parameter 1-98 |
14 | Inputs Button/Switch configuration | Binary inputs type configuration |
15 | Parm 15 | Double-click set lighting at 100% |
16 | Saving state before power failure | Saving state before power failure |
17 | 3-way switch | Function of 3-way switch |
18 | Synchronizing light level for associated devices | The dimmer communicate the level to the associated devices. (default value 0) |
19 | Change [On-Off] bi-stable keys | Function to change [On-Off] bi-stable keys |
20 | Parm 20 | Enable decreasing the minimum level |
30 | Relay 1: Response to General Alarm | |
39 | ALARM FLASHING alarm time | Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame |
40 | Updating the dimming level without switch. | Parameter’s value changes depending on the dimming level. |
41 | Scene activation functionality | Command class scene activation for group no. 3 |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Activate/Deactive ALL ON/OFF
The following option values may be configured -:
Value | Description |
---|---|
-1 | ALL ON active / ALL OFF active |
0 | ALL ON disabled / ALL OFF disabled |
1 | ALL ON disabled / ALL OFF active |
2 | ALL ON active / ALL OFF disabled |
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Activate/Deactivate association sending for group 1 - Also see param #16
The following option values may be configured -:
Value | Description |
---|---|
0 | Map status to all devices in group 1 |
1 | Map OFF status to group 1, memorize state |
2 | Map OFF status group 1, full brightness |
The manufacturer defined default value is 0
(Map status to all devices in group 1).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Key no.2 is not represented by any physical device Key no.2 is not represented by any physical device - only devices in the association list.
This functionality prevents of lack of reaction on pressing key no.2 through polling devices from association list one by one and checking their The following option values may be configured -:
Value | Description |
---|---|
0 | Status not checked |
1 | Status checked |
The manufacturer defined default value is 1
(Status checked).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Options for changing parameter 1-255 (10ms - 2,5s)
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Options for changing parameter 1-255 Options for changing parameter 1-255 (10ms - 2,5s) - 0: this value disables the smooth change in light intensity. NOTE: value 0 is required for inductive and capacitive devices unsuitable for dimming (e.g. fluorescent lamps, motors, etc...) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Options for changing parameter 1-99
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Options for changing parameter 2-99
Values in the range 2 to 99 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Options for changing parameter 1-98
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Binary inputs type configuration
The following option values may be configured -:
Value | Description |
---|---|
0 | Mono-stable input (button) |
1 | Bi-stable input (switch) |
The manufacturer defined default value is 0
(Mono-stable input (button)).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Double-click set lighting at 100%
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable double click |
1 | Enable double click |
The manufacturer defined default value is 0
(Disable double click).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Saving state before power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | State NOT saved at power failure |
1 | State saved at power failure |
The manufacturer defined default value is 1
(State saved at power failure).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Function of 3-way switch The function of 3-way switch provides the option to double key no. 1. The dimmer may control two bi-stable push-buttons or an infinite number of mono-stable push-buttons. (default value 0) The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
The dimmer communicate the level to the associated devices. (default value 0)
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Function to change [On-Off] bi-stable keys This function allow user to change [On-Off] bi-stable keys (parameter no. 14) (default value 0) The following option values may be configured -:
Value | Description |
---|---|
0 | Device changes status on key status change |
1 | Device status depends on key status |
The manufacturer defined default value is 0
(Device changes status on key status change).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Enable decreasing the minimum level This function will enable decreasing the minimum level of the Dimmer by extending the control impulse.[100 - 170]
By changing the minimem level, the user may completely dim LED bulbs.
Not all LED bulbs available on the market support this. Values in the range 100 to 170 may be set.
The manufacturer defined default value is 110
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm relay ON |
2 | Alarm relay OFF |
3 | ALARM FLASHING |
The manufacturer defined default value is 3
(ALARM FLASHING).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_39_2
and is of type INTEGER
.
Parameter’s value changes depending on the dimming level. Available settings: from 1 to 99. Parameter’s value changes depending on the dimming level. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Command class scene activation for group no. 3 The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3. The following option values may be configured -:
Value | Description |
---|---|
0 | Scene functionality deactivated |
1 | Scene functionality activated |
The manufacturer defined default value is 0
(Scene functionality deactivated).
This parameter has the configuration ID config_41_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The FGD211 supports 3 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1 |