This describes the Z-Wave device FGFS101, manufactured by Fibargroup with the thing type UID of fibaro_fgfs101_00_000
.
This version of the device is limited to firmware versions below 3.0
The device is in the category of Sensor, defining Device used to measure something.
The FGFS101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Fibaro Flood Sensor is a universal flood and temperature sensor. Device can be battery (ca. 2 years battery life) or VDC powered (12 or 24 VDC).
Connect a DC power source to include the Fibaro Flood Sensor into the Z-Wave network in autoinclusion mode or triple click TMP button for manual inclusion.
Triple click TMP button
The following table summarises the channels available for the FGFS101 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Binary Sensor | sensor_binary | Door | Switch |
Battery Level | battery-level | Battery | Number |
Alarm (general) | alarm_general | Door | Switch |
Alarm (water) | sensor_flood | Switch | |
Binary Sensor 1 | sensor_binary1 | Door | Switch |
Sensor (temperature) 2 | sensor_temperature2 | Temperature | Number:Temperature |
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates a flood sensor is activated.
The sensor_flood
channel supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Flood |
OFF | OK |
Indicates if a sensor has triggered.
The sensor_binary1
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the current temperature.
The sensor_temperature2
channel supports the Number:Temperature
item and is in the Temperature
category.
The following table provides a summary of the 18 configuration parameters available in the FGFS101. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Alarm Cancellation Delay | Time alarm still indicated after alarm condition has ceased |
2 | Acoustic/visual signals On/Off in case of flooding | LED indicator/acoustic alarm deactivation |
5 | Type alarm frame sent to 1-st assoc group | Type of cmd frame sent in case of flooding |
7 | Forced Level of Dimming group 1 | Parameter specifying forced level of dimming f. asoc grp 1 |
9 | Alarm cancelling or turning a device off | Disable all-clear basic set & alarm frame generation |
10 | Interval betw. successive readings of temp sensors | Interval betw. successive readings of temperature |
12 | Insensitiveness to temperature changes. | Minimum temperature change value |
13 | Alarm BROADCAST | Transmit the alarm or control frame in 'broadcast' mode |
50 | Low temperature alarm threshold | Temperature value below which LED indicator blinks |
51 | High temperature alarm threshold | Temperature value above which LED indicator blinks |
61 | Low temperature alarm indicator colour | Default is blue (0x000000FF). |
62 | High temperature alarm indicator colour | Default is red (0x00FF0000). 65535 * Red + 256 * Green + Blue |
63 | Managing a LED indicator under standard operation | Parameter determines LED indicator’s operation |
73 | Temperature measurement compensation | Temperature value to compensate between air temp |
74 | Alarm frame sent to 2-nd Assoc Grp | Aalarms resulting from sensor’s vibrations |
75 | Visual and audible alarms duration | Visual and audible alarm duration |
76 | Alarm/basic retransmission time when flooding | Time period after which alarm frames will be retransmitted |
77 | Flood sensor functionality turned off | Allows for turning of the internal flood sensor |
Time alarm still indicated after alarm condition has ceased Time period (in seconds) that an alarm will still be indicated after the alarm condition has ceased. Values in the range 0 to 3600 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
LED indicator/acoustic alarm deactivation Parameter allows for LED indicator and acoustic alarm deactivation in case of flooding detection The following option values may be configured -:
Value | Description |
---|---|
0 | Acoustic and visual alarms inactive |
1 | Acoustic alarm inactive, visual alarm active |
2 | Acoustic alarm active, visual alarm inactive |
3 | Acoustic and visual alarms active |
The manufacturer defined default value is 3
(Acoustic and visual alarms active).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Type of cmd frame sent in case of flooding Parameter determines a type of command frame sent by the Sensor in case flooding has been detected or cancelled The following option values may be configured -:
Value | Description |
---|---|
0 | ALARM WATER |
255 | BASIC_SET |
The manufacturer defined default value is 255
(BASIC_SET).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter specifying forced level of dimming f. asoc grp 1 Value of the parameter specifying the forced level of dimming / opening sun blinds when comes 'switch on' / 'open' command to devices from association group 1. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Disable all-clear basic set & alarm frame generation Set to 0 to disable all-clear basic set & alarm frame generation. After flooding, device will keep reporting flooding even if flooding ceased. The following option values may be configured -:
Value | Description |
---|---|
0 | Alarm (flooding) cancellation inactive |
1 | Alarm (flooding) cancellation active |
The manufacturer defined default value is 1
(Alarm (flooding) cancellation active).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Interval betw. successive readings of temperature Interval between successive readings of temperature in seconds. Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Minimum temperature change value Determines a minimum temperature change value (insensitivity level; def: 0,5C), resulting in a temperature report being sent to the main controller, according to the Parameter 10 settings Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Transmit the alarm or control frame in 'broadcast' mode Transmit the alarm or control frame in 'broadcast' mode. Information sent in this mode is not repeated by the mesh network.
NOTE: If the broadcast mode of information transmission is activated for a given alarm, then the information is not relayed through the mesh network. It is only heard by directly reachable devices. The following option values may be configured -:
Value | Description |
---|---|
0 | Broadcast inactive |
1 | Flood broadcast active, Tamper broadcast inactive |
2 | Flood broadcast inactive, Tamper broadcast active |
3 | Flood and Tamper broadcast mode active |
The manufacturer defined default value is 0
(Broadcast inactive).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Temperature value below which LED indicator blinks The parameter stores a temperature value (def. 15C), below which LED indicator blinks with a colour determined by a Parameter 61 settings. By default the LED indicator blinks blue.
Negative numbers are encoded in U2 (two's compliment) standard.
- -1 actual temperature = 65535 reported
- -10000 = 55536
- -32768 = 32768
- 32767 = 32767 Values in the range -10000 to 10000 may be set.
The manufacturer defined default value is 1500
.
This parameter has the configuration ID config_50_2
and is of type INTEGER
.
Temperature value above which LED indicator blinks The parameter stores a temperature value (def. 35C), above which LED indicator blinks with a colour determined by the Parameter 62 settings. By default the LED indicator blinks red Values in the range -10000 to 10000 may be set.
The manufacturer defined default value is 3500
.
This parameter has the configuration ID config_51_2
and is of type INTEGER
.
Default is blue (0x000000FF). NOTE: A main controller interprets colours as a sum of it component colours value. Each colours value is a number from 0 to 255. Eg: Indicated colour = 65536 * RED value + 256 * GREEN value + BLUE value Values in the range 0 to 16777215 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_61_4
and is of type INTEGER
.
Default is red (0x00FF0000). 65535 * Red + 256 * Green + Blue NOTE: A main controller interprets colours as a sum of it component colours value. Each colours value is a number from 0 to 255. Eg: Indicated colour = 65536 * RED value + 256 * GREEN value + BLUE value Values in the range 0 to 16777215 may be set.
The manufacturer defined default value is 16711680
.
This parameter has the configuration ID config_62_4
and is of type INTEGER
.
Parameter determines LED indicator’s operation Parameter determines LED indicator’s operation. Set to 0 turns the indicator off, saving a battery life The following option values may be configured -:
Value | Description |
---|---|
0 | LED indicator doesn’t indicate the temperature |
1 | LED blinks temperature every measurement |
2 | LED indicates the temperature continuously |
The manufacturer defined default value is 2
(LED indicates the temperature continuously).
This parameter has the configuration ID config_63_1
and is of type INTEGER
.
Temperature value to compensate between air temp Parameter stores a temperature value to be added to or deducted from the current temperature measured by internal temperature sensor in order to compensate the difference between air temperature and temperature at the floor level Values in the range -10000 to 10000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_73_2
and is of type INTEGER
.
Aalarms resulting from sensor’s vibrations (MOVEMENT_TAMPER / BUTTON_TAMPER) The device is able to turn on alarms resulting from sensor’s vibrations e.g. when the sensor is moved, or the TMP button released. 2-nd Association Group alarms are not cancelled. The following option values may be configured -:
Value | Description |
---|---|
0 | Tamper alarms inactive |
1 | Button tamper alarm active |
2 | Movement tamper alarm active |
3 | Button and movement tampers alarm active |
The manufacturer defined default value is 2
(Movement tamper alarm active).
This parameter has the configuration ID config_74_1
and is of type INTEGER
.
Visual and audible alarm duration User can silence the Flood Sensor. Because the Sensor’s alarm may last for a long time, it’s possible to turn off visual and audible alarm signaling to save battery. The parameter determines a time period after which alarm will become “quiet” - still active but the device will go into battery saving mode. Visual or acoustic alarm will be reactivated after time period specified in parameter 76. When alarm status ceases, alarm will be turned off immediately.
Value of 0 means visual and accoustic alarms are active indefinitely. In battery power mode sensor will never go to sleep which may shorten battery life significantly. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_75_2
and is of type INTEGER
.
Time period after which alarm frames will be retransmitted Parameter determines time period after which an alarm frame will be retransmitted. Value of 0 disables alarm frame retransmission.
NOTE: In case the time period set in this parameter is shorter than the one specified in parameter 75, the device will not quiet the alarm; it will remain active. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_76_2
and is of type INTEGER
.
Allows for turning of the internal flood sensor Allows for turning of the internal flood sensor. Tamper and built in temperature sensor will remain active The following option values may be configured -:
Value | Description |
---|---|
0 | Default flood sensor operation |
1 | Built in flood sensor TURNED OFF |
The manufacturer defined default value is 0
(Default flood sensor operation ).
This parameter has the configuration ID config_77_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The FGFS101 supports 3 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_SENSOR_ALARM_V1 | Linked to BASIC |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | Linked to BASIC |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.