layout | title |
---|---|
documentation |
FGGC001 - ZWave |
{% include base.html %}
This describes the Z-Wave device FGGC001, manufactured by Fibargroup with the thing type UID of fibaro_fggc001_00_000
.
The device is in the category of Remote Control, defining Any portable or hand-held device that controls the status of something, e.g. remote control, keyfob etc..
The FGGC001 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The FGGC001 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
FIBARO Swipe is a revolutionary battery gesture control pad that allows you to control devices in your Z-Wave network without actually touching anything. Swipe up, down, left, right, make a circular gesture and use sequences to get full and intuitive control of your home.
- Place the Swipe within the direct range of your Z-Wave controller.
- Set the main controller in (security/non-security) add mode (see the controller’s manual).
- Move and hold your hand close to the center of the pad.
- If the device is battery powered, high pitched beep will signal exiting the Standby Mode.
- Loud sound sequence will confrm entering the menu, keep holding your hand.
- After hearing two short beeps (green indicator colour), withdraw the hand and perform swiping up gesture to confrm selection (two beeps will confrm validity).
- Wait for the adding process to end.
- Successful adding will be confrmed by the Z-Wave controller’s message and 3 short beeps (green visual indicator colour).
- Place the Swipe within the direct range of your Z-Wave controller.
- Set the main controller in remove mode (see the controller’s manual).
- Move and hold your hand close to the center of the pad.
- If the device is battery powered, high pitched beep will signal exiting the Standby Mode.
- Loud sound sequence will confrm entering the menu, keep holding your hand.
- After hearing two short beeps (green indicator colour), withdraw the hand and perform swiping up gesture to confrm selection (two beeps will confrm validity).
- Wait for the removing process to end.
- Successful removing will be confrmed by the Z-Wave controller’s message and sequence of 2 short beeps, pause, 1 short beep (red visual indicator colour).
The FGGC001 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Use 1st menu position to wake up the device or click the button on the back of the device once.
The following table summarises the channels available for the FGGC001 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Scene Number | scene_number | Number | |
Battery Level | battery-level | Battery | Number |
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 26 configuration parameters available in the FGGC001. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Device Orientation | Orientation in relation to default position. |
2 | Buzzer - acoustic signal settings | Acoustic signalling of gestures detection. |
3 | LED diode - visual indicator settings | Visual indication of gestures detection |
4 | Buzzer - signalling result of gesture recognition | Acoustic signalling of gesture recognition result (using the built-in buzzer). |
5 | Powering mode - interval of updating the current mode | Check if the USB pwr supply is connected, update pwr mode |
6 | Power saving mode (battery mode) | This parameter determines operation of gesture detection when battery powered. |
7 | Hold gesture to enter the menu | Choose if the menu can be entered using the Hold gesture. |
10 | Scenes sent to the controller | Defines which actions result in sending scenes to 1st “Lifeline” group. |
11 | Associations in Z-Wave network security mode | Define sent command for specified association groups. |
12 | Control mode of 2nd-5th "Flick UP/DOWN/LEFT/RIGHT” | Choose control mode for 2nd-5th groups and scenes. |
13 | Rate of smooth level control | Choose gesture time for "AirWheel" to reach max/min level. |
20 | SWITCH ON control frame value for FLICK UP gesture | Value sent in SWITCH ON command |
21 | SWITCH OFF control frame value for FLICK UP gesture | Value sent in SWITCH OFF command frame. |
22 | SWITCH ON control frame value for FLICK DOWN gesture | Value sent in SWITCH ON command frame. |
23 | SWITCH OFF control frame value for FLICK DOWN gesture | Value sent in SWITCH OFF command frame. |
24 | SWITCH ON control frame value for FLICK LEFT gesture | Value sent in SWITCH ON command frame. |
25 | SWITCH OFF control frame value for FLICK LEFT gesture | Value sent in SWITCH OFF command frame. |
26 | SWITCH ON control frame value for FLICK RIGHT gesture | Value sent in SWITCH ON command frame. |
27 | SWITCH OFF control frame value for FLICK RIGHT gesture | Value sent in SWITCH OFF command frame. |
30 | Sequence learning mode | Launch sequence learning procedure |
31 | 1st gestures sequence (SLOT 1) | Value containing sequence of gestures. |
32 | 2nd gestures sequence (SLOT 2) | Value containing sequence of gestures. |
33 | 3rd gestures sequence (SLOT 3) | Value containing sequence of gestures. |
34 | 4th gestures sequence (SLOT 4) | Value containing sequence of gestures. |
35 | 5th gestures sequence (SLOT 5) | Value containing sequence of gestures. |
36 | 6th gestures sequence (SLOT 6) | Value containing sequence of gestures. |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Orientation in relation to default position. Parameter determines orientation of the Swipe in relation to its default position. The following option values may be configured -:
Value | Description |
---|---|
0 | Default Orientation |
1 | 180° rotation |
2 | 90° clockwise rotation |
3 | 90° counter-clockwise rotation |
The manufacturer defined default value is 0
(Default Orientation).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Acoustic signalling of gestures detection.
The following option values may be configured -:
Value | Description |
---|---|
0 | Gestures detection is not signalled |
1 | Gestures detection is signalled |
The manufacturer defined default value is 1
(Gestures detection is signalled).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Visual indication of gestures detection
The following option values may be configured -:
Value | Description |
---|---|
0 | Gestures detection is not indicated |
1 | Gestures detection is indicated |
The manufacturer defined default value is 0
(Gestures detection is not indicated).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Acoustic signalling of gesture recognition result (using the built-in buzzer). Parameter 4 is relevant only if parameter 2 is set to 1. The following option values may be configured -:
Value | Description |
---|---|
1 | Only successful recognition is signalled |
2 | Only failed recognition is signalled |
3 | Successful and failed recognition is signalled |
The manufacturer defined default value is 3
(Successful and failed recognition is signalled).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Check if the USB pwr supply is connected, update pwr mode This parameter determines how often the device checks if the USB power supply is connected and updates powering mode if needed. The following option values may be configured, in addition to values in the range 0 to 1080 -:
Value | Description |
---|---|
0 | Powering mode is not updated |
1 | Time interval (in minutes) |
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
This parameter determines operation of gesture detection when battery powered. When Standby Mode is selected, hold gesture must be performed to exit power saving mode and reactivate normal gesture recognition. The device in Standby Mode consumes the least battery life.
When Simple Mode mode is selected, gesture recognition is always active, but only slowly performed gestures will be recognized properly (high battery consumption). The following option values may be configured -:
Value | Description |
---|---|
0 | Standby mode |
1 | Simple mode |
2 | Swipe does not enter power saving mode |
The manufacturer defined default value is 0
(Standby mode).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Choose if the menu can be entered using the Hold gesture. This parameter allows to choose if the menu can be entered using the Hold gesture.
After disabling the Hold gesture in parameter 7, menu can be entered by using the B-button only!This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Hold gesture to enter the menu enabled |
1 | Hold gesture to enter the menu disabled |
The manufacturer defined default value is 0
(Hold gesture to enter the menu enabled).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Defines which actions result in sending scenes to 1st “Lifeline” group. Parameter 10 values may be combined, e.g. 1+2=3 means that scenes for flick UP and DOWN are enabled. The following option values may be configured, in addition to values in the range 1 to 63 -:
Value | Description |
---|---|
1 | Scenes for flick UP gesture enabled |
2 | Scenes for flick DOWN gesture enabled |
4 | Scenes for flick LEFT gesture enabled |
8 | Scenes for flick RIGHT gesture enabled |
16 | Scenes for clockwise circular gesture enabled |
32 | Scenes for counter-clockwise circular gesture enabled |
63 | All commands enabled |
The manufacturer defined default value is 15
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
This is a read only parameter.
Define sent command for specified association groups. Parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st “Lifeline” association group.
Parameter 11 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure. The following option values may be configured, in addition to values in the range 1 to 31 -:
Value | Description |
---|---|
1 | 2nd group ”Flick UP” sent as secure |
2 | 3rd group ”Flick DOWN” sent as secure |
4 | 4th group "Flick LEFT” sent as secure |
8 | 5th group "Flick RIGHT” sent as secure |
16 | 6th group "Circular AirWheel” sent as secure |
The manufacturer defined default value is 31
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Choose control mode for 2nd-5th groups and scenes. Parameter allows to choose control mode for 2nd-5th groups and scenes.
By default, Toggle Mode is active, meaning that a single flick turns ON the group and the same flick turns it OFF, doubled flicks are inactive.
After disabling Toggle Mode a single flick will turn the device ON and the same flick doubled will turn it OFF.
Parameter 12 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are selected.
N.B. Disabling Toggle Mode will introduce delay when performing single gestures. The following option values may be configured, in addition to values in the range 1 to 15 -:
Value | Description |
---|---|
1 | Toggle Mode enabled for 2nd association group |
2 | Toggle Mode enabled for 3rd association group |
4 | Toggle Mode enabled for 4th association group |
8 | Toggle Mode enabled for 5th association group |
The manufacturer defined default value is 15
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Choose gesture time for "AirWheel" to reach max/min level. Parameter allows to choose how long the hand has to be held near the center of the pad after "AirWheel" gesture for the associated devices to reach their maximum/minimum level.
Available settings:
0-10 - duration in seconds
255 - default settings of controlled devices Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_13_2
and is of type INTEGER
.
Value sent in SWITCH ON command This parameter allows to set value sent in SWITCH ON command frame to the association group.
Commands sent to association group for turn ON/OFF can be adjusted in parameters 20-27.
0 - turning off associated devices
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them onThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_20_2
and is of type INTEGER
.
Value sent in SWITCH OFF command frame. This parameter allows to set value sent in SWITCH OFF command frame to the association group.
Commands sent to association group for turn ON/OFF can be adjusted in parameters 20-27.
0 - turning off associated devices
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them onThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_21_2
and is of type INTEGER
.
Value sent in SWITCH ON command frame. This parameter allows to set value sent in SWITCH ON command frame to the association group.
Commands sent to association group for turn ON/OFF can be adjusted in parameters 20-27.
0 - turning off associated devices
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them onThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_22_2
and is of type INTEGER
.
Value sent in SWITCH OFF command frame. This parameter allows to set value sent in SWITCH OFF command frame to the association group.
Commands sent to association group for turn ON/OFF can be adjusted in parameters 20-27.
0 - turning off associated devices
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them onThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_23_2
and is of type INTEGER
.
Value sent in SWITCH ON command frame. This parameter allows to set value sent in SWITCH ON command frame to the association group.
Commands sent to association group for turn ON/OFF can be adjusted in parameters 20-27.
0 - turning off associated devices
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them onThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_24_2
and is of type INTEGER
.
Value sent in SWITCH OFF command frame. This parameter allows to set value sent in SWITCH OFF command frame to the association group.
Commands sent to association group for turn ON/OFF can be adjusted in parameters 20-27.
0 - turning off associated devices
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them onThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_25_2
and is of type INTEGER
.
Value sent in SWITCH ON command frame. This parameter allows to set value sent in SWITCH ON command frame to the association group.
Commands sent to association group for turn ON/OFF can be adjusted in parameters 20-27.
0 - turning off associated devices
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them onThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_26_2
and is of type INTEGER
.
Value sent in SWITCH OFF command frame. This parameter allows to set value sent in SWITCH OFF command frame to the association group.
Commands sent to association group for turn ON/OFF can be adjusted in parameters 20-27.
0 - turning off associated devices
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them onThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_27_2
and is of type INTEGER
.
Launch sequence learning procedure Parameter activated by the main Z-Wave controller. Change its value to launch sequence learning procedure for the desired slot.
0 - learning mode disabled
1-6 - launch sequence learning for selected slot
N.B. Sequences do not allow to use same gestures next to each otherThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 6 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Value containing sequence of gestures. User can create sequences of two or three gestures to expand number of possible actions. Every sequence is saved in its advanced parameter (no. 31-36) with 16 bits, every basic gesture is identified with 4 bits. Gesture Value Empty 0 ^ 1 v 2 < 3 > 4
• Maximum of six sequences can be created.
• Each sequence must be unique.
• Sequence can consist of two or three basic gestures (left, right, up
or down).
• Two identical gestures cannot be used next to each other
To manually create or edit a sequence slot:
- Calculate new value of parameter using table and formula:
Value of parameter = 256 * Value of first gesture + 16 * Value of second gesture + Value of third gesture
- Change the value of corresponding parameter (parameters 31 to 36 for slots 1 to 6).
**N.B. Setting parameter to 0 will delete the sequence.**This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1076 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_31_2
and is of type INTEGER
.
Value containing sequence of gestures. User can create sequences of two or three gestures to expand number of possible actions. Every sequence is saved in its advanced parameter (no. 31-36) with 16 bits, every basic gesture is identified with 4 bits.
Gesture Value
Empty 0
^ 1
v 2
< 3
4
Rules of creating sequences:
• Maximum of six sequences can be created.
• Each sequence must be unique.
• Sequence can consist of two or three basic gestures (left, right, up
or down).
• Two identical gestures cannot be used next to each other
To manually create or edit a sequence slot:
- Calculate new value of parameter using table and formula:
Value of parameter = 256 * Value of first gesture + 16 * Value of second gesture + Value of third gesture
- Change the value of corresponding parameter (parameters 31 to 36 for slots 1 to 6).
**N.B. Setting parameter to 0 will delete the sequence.**This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1076 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_32_2
and is of type INTEGER
.
Value containing sequence of gestures. User can create sequences of two or three gestures to expand number of possible actions. Every sequence is saved in its advanced parameter (no. 31-36) with 16 bits, every basic gesture is identified with 4 bits.
Gesture Value
Empty 0
^ 1
v 2
< 3
4
Rules of creating sequences:
• Maximum of six sequences can be created.
• Each sequence must be unique.
• Sequence can consist of two or three basic gestures (left, right, up
or down).
• Two identical gestures cannot be used next to each other
To manually create or edit a sequence slot:
- Calculate new value of parameter using table and formula:
Value of parameter = 256 * Value of first gesture + 16 * Value of second gesture + Value of third gesture
- Change the value of corresponding parameter (parameters 31 to 36 for slots 1 to 6).
**N.B. Setting parameter to 0 will delete the sequence.**This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1076 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_33_2
and is of type INTEGER
.
Value containing sequence of gestures. User can create sequences of two or three gestures to expand number of possible actions. Every sequence is saved in its advanced parameter (no. 31-36) with 16 bits, every basic gesture is identified with 4 bits.
Gesture Value
Empty 0
^ 1
v 2
< 3
4
Rules of creating sequences:
• Maximum of six sequences can be created.
• Each sequence must be unique.
• Sequence can consist of two or three basic gestures (left, right, up
or down).
• Two identical gestures cannot be used next to each other
To manually create or edit a sequence slot:
- Calculate new value of parameter using table and formula:
Value of parameter = 256 * Value of first gesture + 16 * Value of second gesture + Value of third gesture
- Change the value of corresponding parameter (parameters 31 to 36 for slots 1 to 6).
N.B. Setting parameter to 0 will delete the sequence.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1076 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_34_2
and is of type INTEGER
.
Value containing sequence of gestures. User can create sequences of two or three gestures to expand number of possible actions. Every sequence is saved in its advanced parameter (no. 31-36) with 16 bits, every basic gesture is identified with 4 bits.
Gesture Value
Empty 0
^ 1
v 2
< 3
4
Rules of creating sequences:
• Maximum of six sequences can be created.
• Each sequence must be unique.
• Sequence can consist of two or three basic gestures (left, right, up
or down).
• Two identical gestures cannot be used next to each other
To manually create or edit a sequence slot:
- Calculate new value of parameter using table and formula:
Value of parameter = 256 * Value of first gesture + 16 * Value of second gesture + Value of third gesture
- Change the value of corresponding parameter (parameters 31 to 36 for slots 1 to 6).
**N.B. Setting parameter to 0 will delete the sequence.**This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1076 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_35_2
and is of type INTEGER
.
Value containing sequence of gestures. User can create sequences of two or three gestures to expand number of possible actions. Every sequence is saved in its advanced parameter (no. 31-36) with 16 bits, every basic gesture is identified with 4 bits.
Gesture Value
Empty 0
^ 1
v 2
< 3
4
Rules of creating sequences:
• Maximum of six sequences can be created.
• Each sequence must be unique.
• Sequence can consist of two or three basic gestures (left, right, up
or down).
• Two identical gestures cannot be used next to each other
To manually create or edit a sequence slot:
- Calculate new value of parameter using table and formula:
Value of parameter = 256 * Value of first gesture + 16 * Value of second gesture + Value of third gesture
- Change the value of corresponding parameter (parameters 31 to 36 for slots 1 to 6).
**N.B. Setting parameter to 0 will delete the sequence.**This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1076 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_36_2
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The FGGC001 supports 6 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Reports the device status and allows for assigning single device only (main controller by default).
Association group 1 supports 1 node.
Association ensures direct transfer of control commands between devices, is performed without participation of the main controller and requires associated device to be in the direct range.
The Swipe in 2nd to 6th group allows to control 5 regular or multichannel devices per an association group, with the exception of “LifeLine” that is reserved solely for the controller and hence only 1 node can be assigned.
It is not recommended to associate more than 10 devices in general, as the response time to control commands depends on the number of associated devices. In extreme cases, system response may be delayed.
By default 2nd-5th association groups are set to toggle mode - single gesture will reverse state of the association group (turns ON when it’s OFF, turns OFF when it’s ON). Can be modified via parameter 12.
States of the association groups are affected only by assigned gestures. Changing state of associated device by other means will not update remembered state of association group.
Association group 2 supports 5 nodes.
Association ensures direct transfer of control commands between devices, is performed without participation of the main controller and requires associated device to be in the direct range.
The Swipe in 2nd to 6th group allows to control 5 regular or multichannel devices per an association group, with the exception of “LifeLine” that is reserved solely for the controller and hence only 1 node can be assigned.
It is not recommended to associate more than 10 devices in general, as the response time to control commands depends on the number of associated devices. In extreme cases, system response may be delayed.
By default 2nd-5th association groups are set to toggle mode - single gesture will reverse state of the association group (turns ON when it’s OFF, turns OFF when it’s ON). Can be modified via parameter 12.
States of the association groups are affected only by assigned gestures. Changing state of associated device by other means will not update remembered state of association group.
Association group 3 supports 5 nodes.
Association ensures direct transfer of control commands between devices, is performed without participation of the main controller and requires associated device to be in the direct range.
The Swipe in 2nd to 6th group allows to control 5 regular or multichannel devices per an association group, with the exception of “LifeLine” that is reserved solely for the controller and hence only 1 node can be assigned.
It is not recommended to associate more than 10 devices in general, as the response time to control commands depends on the number of associated devices. In extreme cases, system response may be delayed.
By default 2nd-5th association groups are set to toggle mode - single gesture will reverse state of the association group (turns ON when it’s OFF, turns OFF when it’s ON). Can be modified via parameter 12.
States of the association groups are affected only by assigned gestures. Changing state of associated device by other means will not update remembered state of association group.
Association group 4 supports 5 nodes.
Association ensures direct transfer of control commands between devices, is performed without participation of the main controller and requires associated device to be in the direct range.
The Swipe in 2nd to 6th group allows to control 5 regular or multichannel devices per an association group, with the exception of “LifeLine” that is reserved solely for the controller and hence only 1 node can be assigned.
It is not recommended to associate more than 10 devices in general, as the response time to control commands depends on the number of associated devices. In extreme cases, system response may be delayed.
By default 2nd-5th association groups are set to toggle mode - single gesture will reverse state of the association group (turns ON when it’s OFF, turns OFF when it’s ON). Can be modified via parameter 12.
States of the association groups are affected only by assigned gestures. Changing state of associated device by other means will not update remembered state of association group.
Association group 5 supports 5 nodes.
Association ensures direct transfer of control commands between devices, is performed without participation of the main controller and requires associated device to be in the direct range.
The Swipe in 2nd to 6th group allows to control 5 regular or multichannel devices per an association group, with the exception of “LifeLine” that is reserved solely for the controller and hence only 1 node can be assigned.
It is not recommended to associate more than 10 devices in general, as the response time to control commands depends on the number of associated devices. In extreme cases, system response may be delayed.
By default 2nd-5th association groups are set to toggle mode - single gesture will reverse state of the association group (turns ON when it’s OFF, turns OFF when it’s ON). Can be modified via parameter 12.
States of the association groups are affected only by assigned gestures. Changing state of associated device by other means will not update remembered state of association group.
Association group 6 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V2 | Linked to BASIC |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.