layout | title |
---|---|
documentation |
FGMS001 - ZWave |
{% include base.html %}
This describes the Z-Wave device FGMS001, manufactured by Fibargroup with the thing type UID of fibaro_fgms001_03_002
.
This version of the device is limited to firmware versions above 3.2
The device is in the category of Motion Detector, defining Motion sensors/detectors.
The FGMS001 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The FGMS001 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
FIBARO Motion Sensor is a universal Z-Wave multi-sensor. Along with detecting motion the device measures the temperature and light intensity. The sensor has a built-in accelerometer to detect any tampering of the device. FIBARO Motion Sensor is battery powered device and designed to be installed quickly and easily on any surface.
The LED indicator signals motion, temperature level, operating mode and can be used to see if device is within the Z-Wave network. The motion sensor can be used for lighting scenes and presence monitoring systems.
Quickly, three times press the B-button
Quickly, three times press the B-button
The FGMS001 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Press the B-button once
The following table summarises the channels available for the FGMS001 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Binary Sensor | sensor_binary | Switch | |
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Sensor (seismic intensity) | sensor_seismicintensity | Number | |
Sensor (luminance) | sensor_luminance | Number | |
Motion Alarm | alarm_motion | Motion | Switch |
Tamper Alarm | alarm_tamper | Switch | |
Battery Level | battery-level | Battery | Number |
Alarm (general) | alarm_general | Alarm | Switch |
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current seismic intensity level.
The sensor_seismicintensity
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Indicates the current light reading.
The sensor_luminance
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Indicates if a motion alarm is triggered.
The alarm_motion
channel supports the Switch
item and is in the Motion
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if the tamper alarm is triggered.
The alarm_tamper
channel supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 30 configuration parameters available in the FGMS001. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Motion detection - sensitivity | The lower the value, the more sensitive the PIR sensor. |
2 | Motion detection - blind time | Period of time through which the PIR sensor is “blind”. |
3 | Motion detection - pulse counter | Sets the number of moves required for the PIR sensor to report motion. |
4 | Motion detection - window time | The higher the value, the more sensitive the PIR sensor. |
6 | Motion detection - alarm cancellation delay | Period of time after wich Motion alarm will be cancelled. |
8 | Motion detection - operating mode | The parameter determines the part of day in which the PIR sensor will be active. |
9 | Motion detection - night/day | The parameter defines the difference between night and day. |
12 | BASIC command class configuration | Determines the command frames sent in 2nd association group. |
14 | BASIC ON command frame value | The value of 255 allows to turn ON a device. |
16 | BASIC OFF command frame value | The value of 0 allows to turn OFF a device. |
18 | Associations in Z-Wave network Security Mode | This parameter defines how commands are sent in specified association groups |
20 | Tamper - sensitivity | Change in force that will result in tamper alarm |
22 | Tamper - alarm cancellation delay | Time period after which a tamper alarm will be cancelled. |
24 | Tamper - operating modes | This parameter determines function of the tamper and sent reports |
25 | Tamper - alarm cancellation | This parameter allows to disable cancellation of the tamper alarm. |
28 | Tamper - broadcast mode | Determines whether the tamper alarm frame will be sent in broadcast mode |
29 | Tamper - backward compatible broadcast mode | Determines whether the tamper alarm frame will be sent in broadcast mode |
40 | Illuminance report - threshold | Change in light intensity level resulting in illumination report |
42 | Illuminance report - interval | Time interval between consecutive illumination reports |
60 | Temperature report - threshold | The change in temperature resulting in temperature report |
62 | Temperature measuring - interval | How often the temperature will be measured |
64 | Temperature report - interval | How often the temperature reports will be sent |
66 | Temperature offset | Value added to the actual temperature |
80 | LED - signalling mode | LED signalling mode |
81 | LED - brightness | LED brightness |
82 | LED - illuminance for low indicator brightness | Light intensity level below which brightness of visual indicator is set to 1%. |
83 | LED - illuminance for high indicator brightness | Light intensity level above which brightness of visual indicator is set to 100%. |
86 | LED - temperature for blue colour | Minimum temperature resulting in blue LED illumination |
87 | LED - temperature for red colour | Minimum temperature resulting in red LED illumination |
89 | LED - tamper alarm | Indicating mode resembles a police car (white, red and blue |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
The lower the value, the more sensitive the PIR sensor. The lower the value, the more sensitive the PIR sensor. Available settings: 8 - 255. Values in the range 8 to 255 may be set.
The manufacturer defined default value is 15
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
Period of time through which the PIR sensor is “blind”.
Period of time through which the PIR sensor is “blind” (insensitive) to motion. After this time period the PIR sensor will be again able to detect motion. The longer the insensitivity period, the longer the battery life. If the sensor is required to detect motion quickly, the time period may be shortened. The time of insensitivity should be shorter that the time period set in parameter 6.
Available settings: 0 - 15
Formula to calculate the time: time [s] = 0.5 x (value + 1)
Default setting: 3 (1.5 seconds)
Parameter size: 1 [byte]
Values in the range 0 to 15 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Sets the number of moves required for the PIR sensor to report motion.
Sets the number of moves required for the PIR sensor to report motion. The lower the value, the less sensitive the PIR sensor. It’s not recommended to modify this parameter settings.
Available settings: 0 - 3
Formula to calculate the number of pulses: pulses = (value + 1) Default setting: 1 (2 pulses)
Parameter size: 1 [byte]
The following option values may be configured -:
Value | Description |
---|---|
0 | 1 pulse |
1 | 2 pulses |
2 | 3 pulses |
3 | 4 pulses |
The manufacturer defined default value is 1
(2 pulses).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
The higher the value, the more sensitive the PIR sensor.
Period of time during which the number of moves set in parameter 3 must be detected in order for the PIR sensor to report motion. The higher the value, the more sensitive the PIR sensor. It’s not recommended to modify this parameter setting.
Available settings: 0 - 3
Formula to calculate the time: time [s] = 4 x (value + 1)
Default setting: 2 (12 seconds)
Parameter size: 1 [byte]
The following option values may be configured -:
Value | Description |
---|---|
0 | 4 seconds |
1 | 8 seconds |
2 | 12 seconds |
3 | 16 seconds |
The manufacturer defined default value is 2
(12 seconds).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Period of time after wich Motion alarm will be cancelled.
Motion alarm will be cancelled in the main controller and the associated devices after the period of time set in this parameter. Any motion detected during the cancellation delay time countdown will result in the countdown being restarted. In case of small values, below 10 seconds, the value of parameter 2 must be modified (PIR sensor’s “Blind Time”).
Available settings: 1 - 32767
Default setting: 30 (30 seconds)
Parameter size: 2 [bytes]
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
The parameter determines the part of day in which the PIR sensor will be active. The parameter determines the part of day in which the PIR sensor will be active. This parameter influences only the motion reports and associations. Tamper, light intensity and temperature measurements will be still active, regardless of this parameter settings. 0 - PIR sensor always active 1 - PIR sensor active during the day only 2 - PIR sensor active during the night only. Default setting: 0 Parameter size: 1 [byte] The following option values may be configured -:
Value | Description |
---|---|
0 | PIR sensor always active |
1 | PIR sensor active during the day only |
2 | PIR sensor active during the night only |
The manufacturer defined default value is 0
(PIR sensor always active).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
The parameter defines the difference between night and day. The parameter defines the difference between night and day, in terms of light intensity, used in parameter 8. Available settings: 1 - 32767 Default setting: 200 (200 lux) Parameter size: 2 [bytes] Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 200
.
This parameter has the configuration ID config_9_2
and is of type INTEGER
.
Determines the command frames sent in 2nd association group.
The parameter determines the command frames sent in 2nd association group, assigned to PIR sensor.
0 - BASIC ON and BASIC OFF command frames sent in Basic Command Class.
1 - only the BASIC ON command frame sent in Basic Command Class.
2 - only the BASIC OFF command frame sent in Basic CommandClass.
Values of BASIC ON and BASIC OFF command frames may be modified by dedicated parameters.
Default setting: 0 Parameter size: 1 [byte]
The following option values may be configured -:
Value | Description |
---|---|
0 | BASIC ON and BASIC OFF |
1 | Only the BASIC ON |
2 | Only the BASIC OFF |
The manufacturer defined default value is 0
(BASIC ON and BASIC OFF).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
The value of 255 allows to turn ON a device.
The value of 255 allows to turn ON a device. In case of the Dimmer, the value of 255 means turning ON at the last memorized state, e.g. the Dimmer turned ON at 30% and turned OFF using the value of 255, and then turned OFF, will be turned ON at 30%, i.e. the last memorized state.
Available settings: 0 - 255
Default setting: 255
Parameter size: 2 [byte]
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_14_2
and is of type INTEGER
.
The value of 0 allows to turn OFF a device.
The command frame sent at the moment of motion alarm cancellation, after the cancellation delay time, specified in parameter 6, has passed. The value of 0 allows to turn a device OFF while the value of 255 allows to turn ON a device. In case of the Dimmer, the value of 255 means turning ON at the last memorized state, e.g. the Dimmer turned ON at 30% and turned OFF using the value of 255, and then turned OFF, will be turned ON at 30%, i.e. the last memorized state.
Available settings: 0 - 255
Default setting: 0
Parameter size: 2 [byte]
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_16_2
and is of type INTEGER
.
This parameter defines how commands are sent in specified association groups This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is Active only in Z-Wave network security mode. It doesn’t apply to 1st Lifeline group.
Available settings: 0 - 15
0 - all groups sent as non-secure
1 - 2nd group sent as secure
2 - 3rd group sent as secure
4 - 4th group sent as secure
8 - 5th group sent as secure
Parameter values may be combined, e.g. 1+2=3 means that 2nd &
3rd group are sent as secure.
Default setting: 15 (all groups sent as secure)
Parameter size: 1 [byte]
Values in the range 0 to 15 may be set.
The manufacturer defined default value is 15
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Change in force that will result in tamper alarm This parameter determines the change in force acting on the device, that will result in reporting tamper alarm - g-force acceleration.
Available settigs: 0 - 121 (0.08 - 2g; multiply by 0.016g; 0 = tamper inactive)
Default setting: 15 (0.320g)
Parameter size: 1 [byte]
Values in the range 0 to 121 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Time period after which a tamper alarm will be cancelled. Time period after which a tamper alarm will be cancelled in the main controller and associated devices.
Available settings: 1 - 32767
Default setting: 30 (seconds)
Parameter size: 2 [bytes]
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_22_2
and is of type INTEGER
.
This parameter determines function of the tamper and sent reports This parameter determines function of the tamper and sent reports. It is an advanced feature serving much more functions than just detection of tampering.
0 – Only tamper (default)
1 – Tamper and earthquake detector. Function may be used as a simple seismograph. Two reports including the strength of shock are
always sent. First, right after the detection and second (value=0) after tamper alarm cancellation delay time.
2 – Tamper and orientation in space. Three reports are sent right after tamper alarm cancellation delay time.
The following option values may be configured -:
Value | Description |
---|---|
0 | Only tamper (default) |
1 | Tamper and earthquake detector |
2 | Tamper and orientation in space |
The manufacturer defined default value is 0
(Only tamper (default)).
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
This parameter allows to disable cancellation of the tamper alarm.
0 - Do not send tamper cancellation report
1 - Send tamper cancellation report
The following option values may be configured -:
Value | Description |
---|---|
0 | Do not send tamper cancellation report |
1 | Send tamper cancellation report |
The manufacturer defined default value is 1
(Send tamper cancellation report).
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Determines whether the tamper alarm frame will be sent in broadcast mode The parameter determines whether the tamper alarm frame will or will not be sent in broadcast mode. Alarm frames sent in broadcast mode can be received by all of the devices within Communication range (if they accept such frames). When Fibaro Motion Sensor is operating in protected mode (secure mode), the value should remain default. Device operating in protected mode doesn’t send frames in broadcast mode.
0 - Tamper alarm reported to association groups.
1 - Tamper alarm reported in broadcast mode to 3rd association group.
Default setting: 0
Parameter size: 1 [byte]
The following option values may be configured -:
Value | Description |
---|---|
0 | Reported to association groups. |
1 | Reported in broadcast mode to 3rd assoc grp |
The manufacturer defined default value is 0
(Reported to association groups.).
This parameter has the configuration ID config_28_1
and is of type INTEGER
.
Determines whether the tamper alarm frame will be sent in broadcast mode The parameter determines whether the tamper alarm frame will or will not be sent in broadcast mode. Alarm frames sent in broadcast mode can be received by all of the devices within Communication range (if they accept such frames). When Fibaro Motion Sensor is operating in protected mode (secure mode), the value should remain default. Device operating in protected mode doesn’t send frames in broadcast mode.
0 - Tamper alarm reported to association groups.
1 - Tamper alarm reported in broadcast mode to 5th association group.
Default setting: 0
Parameter size: 1 [byte]
The following option values may be configured -:
Value | Description |
---|---|
0 | Reported to association groups. |
1 | Reported in broadcast mode to 5th assoc grp |
The manufacturer defined default value is 0
(Reported to association groups.).
This parameter has the configuration ID config_29_1
and is of type INTEGER
.
Change in light intensity level resulting in illumination report The parameter determines the change in light intensity level resulting in illumination report being sent to the main controller.
Available settings: 0 - 32767 (1-32767 lux; 0=reports are not sent) Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 200
.
This parameter has the configuration ID config_40_2
and is of type INTEGER
.
Time interval between consecutive illumination reports
Time interval between consecutive illumination reports.
The reports are sent even if there are no changes in the light intensity.
Available settings: 0 - 32767 (1-32767 seconds; 0 = no reports)
Default setting: 3600
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
The change in temperature resulting in temperature report
The parameter determines the change in level of temperature resulting in temperature report being sent to the main controller.
Available settings: 0 - 255 (0.1 - 25.5oC; 0 = reports are not sent)
Default setting: 10 (1oC) Parameter size: 2 [byte]
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_60_2
and is of type INTEGER
.
How often the temperature will be measured
The parameter determines how often the temperature will be measured. The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten.
Available settings: 0 - 32767 (1 - 32767 seconds; 0 = temperature will not be measured)
Default setting: 900 (900 seconds)
Parameter size: 2 [bytes]
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 900
.
This parameter has the configuration ID config_62_2
and is of type INTEGER
.
How often the temperature reports will be sent
The parameter determines how often the temperature reports will be sent to the main controller.
Available settings: 0 - 32767 (1 - 32767 seconds; 0 = no reports)
Default setting: 0 Parameter size: 2 [byte]
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_64_2
and is of type INTEGER
.
Value added to the actual temperature
The value to be added to the actual temperature, measured by the sensor (temperature compensation).
Available settings: -1000 – 1000 (-100-100°C, 0.1°C step)
Default setting: 0 Parameter size: 2 [bytes]
Values in the range -1000 to 1000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_66_2
and is of type INTEGER
.
LED signalling mode
The parameter determines the way in which LED diode behaves after motion has been detected.
Values from 1 to 9 = single long blink at the moment of reporting motion. No other motion will be indicated until alarm is cancelled.
Values from 10 to 18 = single long blink at the moment of reporting motion and one short blink each time the motion is detected again.
Values from 19 to 26 = single long blink at the moment of reporting motion and two short blinks each time the motion is detected again.
The following option values may be configured -:
Value | Description |
---|---|
0 | LED inactive. |
1 | LED colour depends on the temperature |
2 | Flashlight mode - LED glows white for 10 sec |
3 | White. |
4 | Red. |
5 | Green. |
6 | Blue. |
7 | Yellow. |
8 | Cyan. |
9 | Magenta. |
10 | LED colour depends on the temperature |
11 | Flashlight mode |
12 | White. |
13 | Red. |
14 | Green. |
15 | Blue. |
16 | Yellow. |
17 | Cyan. |
18 | Magenta. |
19 | LED colour depends on the temperature |
20 | White. |
21 | Red. |
22 | Green. |
23 | Blue. |
24 | Yellow. |
25 | Cyan. |
26 | Magenta. |
The manufacturer defined default value is 10
(LED colour depends on the temperature).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
LED brightness
The parameter determines the brightness of LED when indicating motion.
Available settings: 0 - 100 (1 - 100%; 0 = brightness determined by the ambient lighting - see parameters 82 and 83)
Default setting: 50 Parameter size: 1 [byte]
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_81_1
and is of type INTEGER
.
Light intensity level below which brightness of visual indicator is set to 1%. AMBIENT ILLUMINATION LEVEL BELOW WHICH LED BRIGHTNESS IS SET TO 1%
The parameter is relevant only when the parameter 81 is set to 0.
Available settings: 0 to parameter 83 value
Default setting: 100 (100 lux)
Parameter size: 2 [bytes]
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_82_2
and is of type INTEGER
.
Light intensity level above which brightness of visual indicator is set to 100%. ABOVE WHICH LED BRIGHTNESS IS SET TO 100%
The parameter is relevant only when the parameter 81 is set to 0.
Available settings: parameter 82 value to 65535
Default setting: 1 000 (1 000 lux)
Parameter size: 2 [bytes]
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 1000
.
This parameter has the configuration ID config_83_2
and is of type INTEGER
.
Minimum temperature resulting in blue LED illumination
This parameter is relevant only when parameter 80 has been properly configured.
Available settings: 0 to parameter 87 value (degrees celsius)
Default setting: 18 (18oC)
Parameter size: 2 [byte]
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 18
.
This parameter has the configuration ID config_86_2
and is of type INTEGER
.
Minimum temperature resulting in red LED illumination
This parameter is relevant only when parameter 80 has been properly configured.
Available settings: parameter 86 value to 255 (degrees celsius)
Default setting: 28 (28oC)
Parameter size: 2 [byte]
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 28
.
This parameter has the configuration ID config_87_2
and is of type INTEGER
.
Indicating mode resembles a police car (white, red and blue
The following option values may be configured -:
Value | Description |
---|---|
0 | LED does not indicate tamper alarm. |
1 | LED indicates tamper alarm. |
The manufacturer defined default value is 1
(LED indicates tamper alarm.).
This parameter has the configuration ID config_89_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The FGMS001 supports 5 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Device status "Lifeline" is a reporting group, assigned to the device status. Main Z-Wave+ network controller should be added to this group. The "Lifeline" group can handle only one device. If Fibaro Motion Sensor operates in protected mode, outgoing messages are always encrypted.
Association group 1 supports 1 node.
"Motion" is assigned to the motion sensor. At the moment of motion detection or alarm state cancellation, nodes added to this group will receive control frames. The "Motion" group can handle up to five devices (one or multi-channel). If Fibaro Motion Sensor operates in protected mode, outgoing messages are encrypted, depending on whether the added node also operates in secure mode.
Association group 2 supports 5 nodes.
"Tamper" is assigned to the tamper alarm. Once tampering is detected or cancelled, nodes added to this group will receive alarm frames. The "Tamper" group can handle up to five devices (one or multi-channel). If Fibaro Motion Sensor operates in protected mode, outgoing messages are always encrypted.
Association group 3 supports 5 nodes.
Motion BC (backward compatibility) "Motion BC" is assigned to the motion sensor. Once motion is detected or alarm state cancelled, nodes added to this group will receive report frames. This group aims to provide backward compatibility with controllers not supporting the Z-Wave+ protocol. Only a main controller not supporting the Z-wave+ protocol should be added to this group. The "Motion BC" group can handle up to five devices (one or multi-channel). If Fibaro Motion Sensor operates in protected mode, outgoing messages are always encrypted.
Association group 4 supports 5 nodes.
Tamper BC (backward compability) "Tamper BC" is assigned to the tamper alarm. Once tampering is detected or cancelled, nodes added to this group will receive alarm frames. This group aims to provide backward compatibility with devices not supporting the Z-Wave+ protocol. Only nodes not supporting the Z-wave+ protocol should be added to this group. The "Tamper BC" group can handle up to five devices (one or multi-channel). If Fibaro Motion Sensor operates in protected mode, outgoing messages are always encrypted. The Fibaro Motion Sensor allows for controlling 5 regular and 5 multichannel devices per an association group, out of which 1 field is reserved for the Z-Wave network main controller.
Association group 5 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_SENSOR_ALARM_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.