This describes the Z-Wave device FGS222, manufactured by Fibargroup with the thing type UID of fibaro_fgs222_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The FGS222 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Remotely Controlled Relay Switch of Fibaro System is designed to operate in a wall switch box or in locations where the control of an electric device (up to 3kW) is needed.
It is also possible to send a signal to any system that is to be integrated with Fibaro system.
Add Fibaro Switch to the network by pushing three times key no. 1 or push-button B located inside the housing of the device. For toggle switch perform 3 position changes.
Remove Fibaro Switch from the network by pushing three times key no. 1 or push-button B located inside the housing of the device. For toggle switch perform 3 position changes.
The following table summarises the channels available for the FGS222 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Switch 1 | switch_binary1 | Switch | Switch |
Switch 2 | switch_binary2 | Switch | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Switch the power on and off.
The switch_binary1
channel supports the Switch
item and is in the Switch
category.
Switch the power on and off.
The switch_binary2
channel supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 19 configuration parameters available in the FGS222. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Enable/Disable ALL ON/OFF | Activate/Deactive ALL ON/OFF |
3 | Override OFF-delay | Forced auto off period |
4 | Relay 1: OFF-delay time (100ms steps) | Auto off relay 1 after set time, in 100ms increments (default: 0 - off) |
5 | Relay 2: OFF-delay time (100ms steps) | Auto off relay 2 after set time, in 100ms increments (default: 0 - off) |
6 | Separation of association sending (key 1) | Activate/Deactivate association sending for group 1 - Also see param #16 |
7 | Control key #2 behaviour | ![CDATA[NOTE: Parameter 15 value must be set to 1 to work properly. |
13 | Inputs behaviour | In case of bi-stable switches, define their behaviour (toggle or follow) |
14 | Inputs Button/Switch configuration | Binary inputs type configuration |
15 | Dimmer/Roller shutter control | Enable/Disable operation of devices associated to group 1 |
16 | Saving state before power failure | Saving state before power failure |
30 | Relay 1: Response to General Alarm | |
31 | Relay 1: Response to Water Flood Alarm | |
32 | Relay 1: Response to Smoke, CO, CO2 Alarm | |
33 | Relay 1: Response to Temperature Alarm | |
39 | ALARM FLASHING alarm time | Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame |
40 | Relay 2: Response to General Alarm | |
41 | Relay 2: Response to Water Flood Alarm | |
42 | Relay 2: Response to Smoke, CO, CO2 Alarm | |
43 | Relay 2: Response to Temperature Alarm | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Activate/Deactive ALL ON/OFF
The following option values may be configured -:
Value | Description |
---|---|
-1 | ALL ON active / ALL OFF active |
0 | ALL ON disabled/ ALL OFF disabled |
1 | ALL ON disabled/ ALL OFF active |
2 | ALL ON active / ALL OFF disabled |
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Forced auto off period If Parameter 4 or 5 states an auto off period, this parameter enable the possibility to turn off the relay with a button push. Default value 0 disallow turn off with a button push during the auto off interval. The following option values may be configured -:
Value | Description |
---|---|
0 | Manual override disabled |
1 | Manual override enabled. |
The manufacturer defined default value is 0
(Manual override disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Auto off relay 1 after set time, in 100ms increments (default: 0 - off)
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Auto off relay 2 after set time, in 100ms increments (default: 0 - off)
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
Activate/Deactivate association sending for group 1 - Also see param #16
The following option values may be configured -:
Value | Description |
---|---|
0 | Commands sent when device is turned on/off. |
1 | Commands sent when device turned off. |
2 | Commands sent when device turned off. |
The manufacturer defined default value is 0
(Commands sent when device is turned on/off.).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
![CDATA[NOTE: Parameter 15 value must be set to 1 to work properly.
The following option values may be configured -:
Value | Description |
---|---|
0 | Commands sent when device is turned on/off |
1 | Commands sent when turned off-last state |
2 | Commands sent when turned off-full brightness |
The manufacturer defined default value is 1
(Commands sent when turned off-last state).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
In case of bi-stable switches, define their behaviour (toggle or follow)
The following option values may be configured -:
Value | Description |
---|---|
0 | Toggle |
1 | Follow switch contact (closed=ON, open=OFF) |
The manufacturer defined default value is 0
(Toggle).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Binary inputs type configuration
The following option values may be configured -:
Value | Description |
---|---|
0 | Mono-stable input (button) |
1 | Bi-stable input (switch) |
The manufacturer defined default value is 1
(Bi-stable input (switch)).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Enable/Disable operation of devices associated to group 1 Enable/Disable operation of dimmer or roller shutter devices associated to group 1. Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Dimmer/Roller shutter control |
1 | Enable Dimmer/Roller shutter control |
The manufacturer defined default value is 0
(Disable Dimmer/Roller shutter control).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Saving state before power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | State NOT saved at power failure |
1 | State saved at power failure |
The manufacturer defined default value is 1
(State saved at power failure).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 3
(Alarm Flashing).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 2
(Alarm Relay OFF).
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 3
(Alarm Flashing).
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 1
(Alarm Relay ON).
This parameter has the configuration ID config_33_1
and is of type INTEGER
.
Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_39_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 3
(Alarm Flashing).
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 2
(Alarm Relay OFF).
This parameter has the configuration ID config_41_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 3
(Alarm Flashing).
This parameter has the configuration ID config_42_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 1
(Alarm Relay ON).
This parameter has the configuration ID config_43_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The FGS222 supports 3 association groups.
Association group 1 supports 16 nodes.
Association group 2 supports 16 nodes.
Association group 3 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |