This describes the Z-Wave device MIMOlite, manufactured by FortrezZ LLC with the thing type UID of fortrezz_mimolite_00_000
.
The device is in the category of Sensor, defining Device used to measure something.
The MIMOlite supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The MIMOlite module provides one analog or digital input and one relay output (isolated dry contacts, NO-COM-NC) and can be controlled by ZWaveTM. The system includes a program switch for Z-WaveTM inclusion/exclusion and a status light (LED) for various indications.
Input SIG1 is an analog input, internally pulled-up to the MIMOlite supply voltage. The system allows trigger conditions to be set based on the input voltage being inside or outside a user-defined range (configured via Z-Wave). This provides great flexibility for capturing events in a wide variety of applications. The trigger status of the input can be read via Z-WaveTM and/or can be automatically sent to a configured node, typically the Controller. In addition, a count of the trigger events that have occurred for the input channel is internally recorded (and stored in the ‘pulse count’) and is available to be requested or automatically sent via Z-Wave. The current triggered/un-triggered status can also be read via ZWave.
The SIG1 input can be associated with up to two other Z-WaveTM devices, such that an associated device will automatically turn on (or off) based on the occurrence of a trigger event. Finally, the analog input channel can be configured so that the analog input level (not just binary trigger status) is periodically sent to up to two other associated nodes.
The output relay is typically commanded via Z-WaveTM commands. In addition, the user can configure the input SIG1 trigger condition to be mapped to the output relay. For example, Relay 1 can be automatically turned on based on Input SIG1 being triggered. The relay activation can be set via a jumper or via Z-WaveTM for either momentary or latched operation.
- Set up the inclusion mode at the controller (for detailed directions, please refer to your controller user manual)
- If the LED has a periodic single blink, the unit will be automatically included. Otherwise, the button has been previously pressed and automatic inclusion mode is no longer active. In this case, briefly press the button once and the controller will indicate that the unit has been included in the network. Also, the Status LED will blink when the inclusion completes. Inclusion and exclusion are always done at normal transmit power mode.
- Set up the exclusion mode at the controller (for detailed directions, please refer to your controller user manual)
- Press the MIMOlite button and the controller will indicate the unit has been removed from the network. The Status LED will blink when the exclusion completes.
The following table summarises the channels available for the MIMOlite -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Binary Sensor | sensor_binary | Door | Switch |
Sensor (general) | sensor_general | Number | |
Alarm | alarm_general | Door | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
The sensor_general
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 9 configuration parameters available in the MIMOlite. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | Clear_Pulse_Meter_Counts | |
3 | Trigger_Mapping | Input-to-relay Mapping |
4 | Lower_Threshold_High | Lower Threshold, High |
5 | Lower_Threshold_Low | Lower Threshold, Low |
6 | Upper_Threshold_High | Upper Threshold, High |
7 | Upper_Threshold_Low | Upper Threshold, Low |
8 | Trigger_Level_And_Input_Threshold | |
9 | Multilevel_AutoReport_Interval | Multilevel AutoReport Interval |
11 | Momentary_Relay1_Duration | Momentary Relay1 output enable/disable (100msec). |
The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
0 | Clear Pulse Meter Counts |
The manufacturer defined default value is 0
(Clear Pulse Meter Counts).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Input-to-relay Mapping The MIMOlite can be configured to automatically turn the relay on when the input is triggered or a Z-Wave command can also turn the relay on. The Configuration Command Class, Parameter 3, is used to set the input-to-relay mapping (See Technical Appendix). When input-to-relay mapping is enabled, Z-WaveTM commands to set the relay are overridden. The default for the relay is no input-to-relay mapping. Momentary vs Latched relay operation is selected by jumper P5 on the circuit board. The Momentary/Latched jumper is read only at power on when the MIMOlite is not in a ZWave network. When the jumper is off, momentary (default 500ms) operation is selected. If desired, once in-network, a Zwave configuration command (Parameter 11) can be used to override the jumper setting. The momentary configuration can be set from 100ms to 25.5ms (approximate) in increments of 100ms via the ZWave command.
Note that neither a Basic Report nor a Binary Switch Report is sent when relay is automatically set or cleared by Trigger Mapping. The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
0 | Disabled |
1 | SIG1 triggered/untriggered sets or clears Relay1 |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Lower Threshold, High Lower Threshold, High (Default=0xBB; must be less than Upper Threshold Low and greater than Lower Threshold Low). The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
187 | Default (0xBB) |
The manufacturer defined default value is 187
(Default (0xBB)).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Lower Threshold, Low
The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
171 | Default (0xAB) |
The manufacturer defined default value is 171
(Default (0xAB)).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Upper Threshold, High
The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
255 | Default (0xFF) |
The manufacturer defined default value is 255
(Default (0xFF)).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Upper Threshold, Low Upper Threshold, Low (Default = 0xFE; must be greater than Lower Threshold High and less than Upper Threshold High). The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
254 | Default (0xFE) |
The manufacturer defined default value is 254
(Default (0xFE)).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | ANALOG, trigger OUTSIDE of thresholds. |
1 | ANALOG, trigger BETWEEN thresholds. |
2 | DIGITAL, trigger OUTSIDE of thresholds. |
3 | DIGITAL, trigger BETWEEN thresholds. |
The manufacturer defined default value is 3
(DIGITAL, trigger BETWEEN thresholds.).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Multilevel AutoReport Interval Periodic send interval of Multilevel Sensor Reports (Association Group 2) and/or Pulse Count Reports (Association Group 5) for SIG1. This parameter has a resolution of 10 seconds; for example, 1 = 10 seconds, 2 = 20 seconds, 3 = 30 seconds (Default), …, 255 = 2550 seconds = 42.5 minutes. A value of 0 disables automatic reporting. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Automatic Reports |
3 | Enable Reports every 30 seconds (Default) |
The manufacturer defined default value is 3
(Enable Reports every 30 seconds (Default)).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Momentary Relay1 output enable/disable (100msec). Momentary Relay1 output enable/disable. 0 = disable (Default) 1..255 = enable / value sets the approximate momentary on time in increments of 100msec. The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
0 | Disabled (Default) |
5 | 500 milliseconds |
The manufacturer defined default value is 0
(Disabled (Default)).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The MIMOlite supports 5 association groups.
When the input is triggered or untriggered, the MIMOlite will automatically send a Basic Set command to turn on or off the device(s) associated with this group.
Association group 1 supports 2 nodes.
The MIMOlite will periodically send a MultiLevel Sensor report indicating the input’s analog voltage level.
Association group 2 supports 2 nodes.
If a power dropout occurs, the MIMOlite will send an Alarm Command Class report (if there is enough available residual power).
Association group 3 supports 2 nodes.
When the input is triggered or untriggered, the MIMOlite will automatically send a Binary Sensor report to this group’s associated device(s).
Association group 4 supports 2 nodes.
Pulse meter counts will be sent to this group’s associated device(s). This will be sent periodically at the same intervals as Association Group 2, MLS Report except that if the pulse meter count is unchanged the report will not be sent.
Association group 5 supports 2 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |