12718 - ZWave

{% include base.html %}

12718 Smart Dimmer

This describes the Z-Wave device 12718, manufactured by Jasco Products with the thing type UID of ge_12718_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

The 12718 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the 12718 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the 12718. Detailed information on each parameter can be found in the sections below.

Param Name Description
7 Dimmer steps number of steps or levels
8 Time between dimmer steps Timing of the steps (10ms increments)
29 Load sensing Turn load sensing on or off
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 7: Dimmer steps

number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Time between dimmer steps

Timing of the steps (10ms increments)

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 29: Load sensing

Turn load sensing on or off

The following option values may be configured -:

Value Description
0 disable (default)
1 enable load sensing

The manufacturer defined default value is 0 (disable (default)).

This parameter has the configuration ID config_29_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_VERSION_V1

Documentation Links