This describes the Z-Wave device 12727, manufactured by Jasco Products with the thing type UID of ge_12727_00_000
.
The 12727 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
-
Follow the instructions for your Z-wave certified controller to include a device to the Z-wave network.
-
Once the controller is ready to include your device, press up and release the toggle switch to include it in the network.
Note: Your controller may need to be within 10 feet of the device to be included.
- Once your controller has confirmed that the device has been included, refresh the Z-wave network to optimize performance.
The following table summarises the channels available for the 12727 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 2 configuration parameters available in the 12727. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
4 | Invert switch | Invert switch |
29 | Load Sensing | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Invert switch If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”. The following option values may be configured -:
Value | Description |
---|---|
0 | Normal switch install |
1 | Inverted switch |
The manufacturer defined default value is 0
(Normal switch install).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Load Sensing Load sensing is disabled when shipped from the factory. This feature can be enabled if desired. Setting parameter 29 to a value of 1 will enable the Load Sense function Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_29_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.