layout title
documentation
45605 - ZWave

{% include base.html %}

45605 Duplex receptacle

This describes the Z-Wave device 45605, manufactured by Jasco Products with the thing type UID of ge_45605_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

45605 product image

The 45605 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the 45605 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Night Light config_decimal Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Night Light

Defines the behaviour of the blue LED

0 = LED on when switch is OFF

1 = LED on when switch is ON

2 = LED always OFF

Generic class for configuration parameter.

The config_decimal channel supports the Number item.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the 45605. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Night Light Defines the behavior of the blue LED.
4 Invert Switch Change the top of the switch to OFF
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Night Light

Defines the behavior of the blue LED. Default is Night Light mode where LED is on when switch is off. The following option values may be configured -:

Value Description
0 LED on when switch is OFF
1 LED on when switch is ON
2 LED always off

The manufacturer defined default value is 0 (LED on when switch is OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Change the top of the switch to OFF Change the top of the switch to OFF and the bottom of the switch to ON.

Note: If you invert the switches and also install the product upside down remember the load will now be controlled by the right, not the left switch. The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.