GE 12725 In-Wall Dimmer

This describes the Z-Wave device GE 12725, manufactured by Jasco Products with the thing type UID of ge_ge12725_00_000.

GE 12725 product image

The GE 12725 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the GE 12725 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the GE 12725. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Night Light Defines the behavior of the blue LED.
Default is Night Light mode where LED is on when switch is off.
4 Invert Switch Invert the ON/OFF Switch State.
Setting this parameter to Yes will change the top of the switch to OFF and the bottom to ON.
Note: If you invert the switches and also install the product upside down, the load will now be control
5 Ignore Start-Level (Receiving) This dimmer will start dimming from its current level.
7 On/Off Command Dim Step Indicates how many levels the dimmer will change for each dimming step.
8 On/Off Command Dim Rate This value indicates in 10 millisecond resolution.
This sets how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the
9 Local Control Dim Step Indicates how many levels the dimmer will change for each dimming step.
10 Local Control Dim Rate This value indicates in 10 millisecond resolution.
This sets how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the
11 ALL ON/ALL OFF Dim Step Indicates how many levels the dimmer will change for each dimming step.
12 ALL ON/ALL OFF Dim Rate This value indicates in 10 millisecond resolution.
This sets how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Night Light

Defines the behavior of the blue LED.
Default is Night Light mode where LED is on when switch is off.

The following option values may be configured -:

Value Description
0 LED on when switch is OFF
1 LED on when switch is ON
2 LED always off

The manufacturer defined default value is 0 (LED on when switch is OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Invert the ON/OFF Switch State.
Setting this parameter to Yes will change the top of the switch to OFF and the bottom to ON.
Note: If you invert the switches and also install the product upside down, the load will now be control

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Ignore Start-Level (Receiving)

This dimmer will start dimming from its current level.

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 7: On/Off Command Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: On/Off Command Dim Rate

This value indicates in 10 millisecond resolution.
This sets how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Local Control Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Local Control Dim Rate

This value indicates in 10 millisecond resolution.
This sets how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: ALL ON/ALL OFF Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: ALL ON/ALL OFF Dim Rate

This value indicates in 10 millisecond resolution.
This sets how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1