layout | title |
---|---|
documentation |
GE 14291 (ZW4005) - ZWave |
{% include base.html %}
This describes the Z-Wave device GE 14291 (ZW4005), manufactured by Jasco Products with the thing type UID of ge_ge14291_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The GE 14291 (ZW4005) supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the GE 14291 (ZW4005) -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Scene Number | scene_number | Number |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
The following table provides a summary of the 2 configuration parameters available in the GE 14291 (ZW4005). Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Night Light | Defines the behavior of the blue LED. Default is on when switch is off. |
4 | Invert Switch | Invert the ON/OFF Switch State. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Defines the behavior of the blue LED. Default is on when switch is off.
The following option values may be configured -:
Value | Description |
---|---|
0 | LED on when switch is OFF |
1 | LED on when switch is ON |
2 | LED always off |
The manufacturer defined default value is 0
(LED on when switch is OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Invert the ON/OFF Switch State.
The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes |
The manufacturer defined default value is 0
(No).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GE 14291 (ZW4005) supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.