layout title
documentation
GE 14295 - ZWave

{% include base.html %}

GE 14295 In-Wall Dimmer Switch

This describes the Z-Wave device GE 14295, manufactured by Jasco Products with the thing type UID of ge_ge14295_00_000.

GE 14295 product image

The GE 14295 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Inclusion Information

  1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network.

  2. Once the controller is ready to include your device, press and release the top or bottom of the wireless smart dimmer(rocker) to include it in the network. 

Exclusion Information

  1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.

  2. Once the controller is ready to Exclude your device, press and release the top or bottom of the wireless smart dimmer (rocker) to exclude it from the network. 

Channels

The following table summarises the channels available for the GE 14295 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the GE 14295. Detailed information on each parameter can be found in the sections below.

Param Name Description
4 Invert Switch Invert the ON/OFF Switch State.
7 Dim Rate Adjustments Number of steps or levels
8 Dim Rate Adjustments Timing of steps or levels
9 Dim Rate Adjustments Number of steps or levels
10 Dim Rate Adjustments Timing of steps
11 Dim Rate Adjustments Number of steps or levels
12 Dim Rate Adjustments Timing of steps or levels
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 4: Invert Switch

Invert the ON/OFF Switch State.

The following option values may be configured -:

Value Description
0 (Default) No
1 Yes

The manufacturer defined default value is 0 ((Default) No).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 7: Dim Rate Adjustments

Number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Dim Rate Adjustments

Timing of steps or levels

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Dim Rate Adjustments

Number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Dim Rate Adjustments

Timing of steps

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Dim Rate Adjustments

Number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Dim Rate Adjustments

Timing of steps or levels

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The GE 14295 supports 3 association groups.

Group 1: Association Group 1

Z-Wave Plus Lifeline, Multilevel Switch Report

Association group 1 supports 5 nodes.

Group 2: Association Group 2

Supports Basic Set and is controlled with the local load

Association group 2 supports 5 nodes.

Group 3: Association Group 3

Supports Basic Set and is controlled by double pressing the On or Off button

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.