layout | title |
---|---|
documentation |
ZW4005, 12722 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZW4005, 12722, manufactured by Jasco Products with the thing type UID of ge_zw4005_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZW4005, 12722 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Also marketed as GE / Jasco 12722.
The following table summarises the channels available for the ZW4005, 12722 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 2 configuration parameters available in the ZW4005, 12722. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Night Light | Defines the behavior of the blue LED. |
Default is Night Light mode where LED is on when switch is off. | ||
4 | Invert Switch | Invert the ON/OFF Switch State. |
Setting this parameter to Yes will change the top of the switch to OFF and the bottom to ON. | ||
Note: If you invert the switches and also install the product upside down, the load will now be control | ||
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Defines the behavior of the blue LED.
Default is Night Light mode where LED is on when switch is off.
The following option values may be configured -:
Value | Description |
---|---|
0 | LED on when switch is OFF |
1 | LED on when switch is ON |
2 | LED always off |
The manufacturer defined default value is 0
(LED on when switch is OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Invert the ON/OFF Switch State.
Setting this parameter to Yes will change the top of the switch to OFF and the bottom to ON.
Note: If you invert the switches and also install the product upside down, the load will now be control
The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes |
The manufacturer defined default value is 0
(No).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.