78008 Door/Window Sensor with Magnet

This describes the Z-Wave device 78008, manufactured by Good Way Technology Co., Ltd with the thing type UID of goodway_78008_00_000.

The device is in the category of Door, defining Door sensors.

78008 product image

The 78008 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-Wave Door/Window sensor with magnet

can include 2 extern sensors

Inclusion Information

  1. Install the battery and close the lid

  2. Set your gateway/controller to the inclusion mode

  3. Push the TMP button on the bottom side 3 times in 2 seconds

  4. if the inclusion was succesfully the software will show it

Exclusion Information

  1. Set your gateway/controller to the exclusion mode

2. Push the TMP button on the bottom side 3 times in 2 seconds

  1. The device is logged off

Channels

The following table summarises the channels available for the 78008 -:

Channel Channel Id Category Item Type
Binary Sensor sensor_binary Door Switch
Alarm alarm_general Door Switch
Battery Level battery-level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the 78008. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Basic set level for nodes of group2 255: Binary switch ON, 1-99: Dimmer level
2 Basic set OFF delay time for nodes of group2 0: Disable, 0-127 Second
3 Delay time to enter standby mode After force to wake up, delay time to enter standby mode again
4 In standby, delay time to enter standby after wake up In standby mode, after wake up, delay time for standby again
5 Set waiting exclusion time Set waiting exclusion time
6 Activate/Deactivate WUT standby mode 0: Always wake up, 1: Enter standby mode
7 Activate/Deactivate Tamper alarm mode 0: Disable, 1: Enable
8 Tamper alarm continuously send In tamper alarm mode, delay time for continuously send Sensor_Binary_report
9 Interval time for sending battery report The interval time of sending battery report
10 set the configuration of 2 external sensors BIT0: sensor1 (S1), BIT1: sensor2 (S2)
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 1: Basic set level for nodes of group2

255: Binary switch ON, 1-99: Dimmer level 255: Binary switch ON

1-99: Dimmer level  Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Basic set OFF delay time for nodes of group2

0: Disable, 0-127 Second 0: Disable

0-127 Seconds Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Delay time to enter standby mode

After force to wake up, delay time to enter standby mode again After force to wake up, delay time to enter standby mode again Values in the range 1 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: In standby, delay time to enter standby after wake up

In standby mode, after wake up, delay time for standby again In standby mode, after wake up, delay time for standby again Values in the range 1 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Set waiting exclusion time

Set waiting exclusion time

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Activate/Deactivate WUT standby mode

0: Always wake up, 1: Enter standby mode 0: Always wake up

1: Enter standby mode

(Auto-reboot after setting completed) The following option values may be configured -:

Value Description
0 Alwas wake up
1 Enter standby mode

The manufacturer defined default value is 1 (Enter standby mode).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Activate/Deactivate Tamper alarm mode

0: Disable, 1: Enable 0: Disable tamper alarm mode

1: Enable tamper alarm mode

(Auto reboot after setting completed) The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Tamper alarm continuously send

In tamper alarm mode, delay time for continuously send Sensor_Binary_report In tamper alarm mode, delay time for continuously send Sensor_Binary_report Values in the range 3 to 30 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Interval time for sending battery report

The interval time of sending battery report The interval time of sending battery report when the battery runs out of electricity The following option values may be configured -:

Value Description
3 3 minutes
5 5 minutes
10 10 minutes

The manufacturer defined default value is 3 (3 minutes).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: set the configuration of 2 external sensors

BIT0: sensor1 (S1), BIT1: sensor2 (S2) BIT0: sensor1 (S1)

BIT1: sensor2 (S2)

0 (00b): S2 NO, S1 NO

1 (01b): S2 NO, S1 NC

2 (10b): S2 NC, S1 NO

3 (11b): S2 NC, S1 NC Values in the range 0 to 3 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 78008 supports 2 association groups.

Group 1: Reports

All autoreports send to Group 1

Association group 1 supports 1 node.

Group 2: Sensor

ON/OFF status (Basic_set command)

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1