This describes the Z-Wave device 78008, manufactured by Good Way Technology Co., Ltd with the thing type UID of goodway_78008_00_000
.
The device is in the category of Door, defining Door sensors.
The 78008 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Z-Wave Door/Window sensor with magnet
can include 2 extern sensors
-
Install the battery and close the lid
-
Set your gateway/controller to the inclusion mode
-
Push the TMP button on the bottom side 3 times in 2 seconds
-
if the inclusion was succesfully the software will show it
- Set your gateway/controller to the exclusion mode
2. Push the TMP button on the bottom side 3 times in 2 seconds
- The device is logged off
The following table summarises the channels available for the 78008 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Binary Sensor | sensor_binary | Door | Switch |
Alarm | alarm_general | Door | Switch |
Battery Level | battery-level | Battery | Number |
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 10 configuration parameters available in the 78008. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Basic set level for nodes of group2 | 255: Binary switch ON, 1-99: Dimmer level |
2 | Basic set OFF delay time for nodes of group2 | 0: Disable, 0-127 Second |
3 | Delay time to enter standby mode | After force to wake up, delay time to enter standby mode again |
4 | In standby, delay time to enter standby after wake up | In standby mode, after wake up, delay time for standby again |
5 | Set waiting exclusion time | Set waiting exclusion time |
6 | Activate/Deactivate WUT standby mode | 0: Always wake up, 1: Enter standby mode |
7 | Activate/Deactivate Tamper alarm mode | 0: Disable, 1: Enable |
8 | Tamper alarm continuously send | In tamper alarm mode, delay time for continuously send Sensor_Binary_report |
9 | Interval time for sending battery report | The interval time of sending battery report |
10 | set the configuration of 2 external sensors | BIT0: sensor1 (S1), BIT1: sensor2 (S2) |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
255: Binary switch ON, 1-99: Dimmer level 255: Binary switch ON
1-99: Dimmer level Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
0: Disable, 0-127 Second 0: Disable
0-127 Seconds Values in the range 0 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
After force to wake up, delay time to enter standby mode again After force to wake up, delay time to enter standby mode again Values in the range 1 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
In standby mode, after wake up, delay time for standby again In standby mode, after wake up, delay time for standby again Values in the range 1 to 255 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Set waiting exclusion time
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
0: Always wake up, 1: Enter standby mode 0: Always wake up
1: Enter standby mode
(Auto-reboot after setting completed) The following option values may be configured -:
Value | Description |
---|---|
0 | Alwas wake up |
1 | Enter standby mode |
The manufacturer defined default value is 1
(Enter standby mode).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
0: Disable, 1: Enable 0: Disable tamper alarm mode
1: Enable tamper alarm mode
(Auto reboot after setting completed) The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
In tamper alarm mode, delay time for continuously send Sensor_Binary_report In tamper alarm mode, delay time for continuously send Sensor_Binary_report Values in the range 3 to 30 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
The interval time of sending battery report The interval time of sending battery report when the battery runs out of electricity The following option values may be configured -:
Value | Description |
---|---|
3 | 3 minutes |
5 | 5 minutes |
10 | 10 minutes |
The manufacturer defined default value is 3
(3 minutes).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
BIT0: sensor1 (S1), BIT1: sensor2 (S2) BIT0: sensor1 (S1)
BIT1: sensor2 (S2)
0 (00b): S2 NO, S1 NO
1 (01b): S2 NO, S1 NC
2 (10b): S2 NC, S1 NO
3 (11b): S2 NC, S1 NC Values in the range 0 to 3 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 78008 supports 2 association groups.
All autoreports send to Group 1
Association group 1 supports 1 node.
ON/OFF status (Basic_set command)
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |