layout | title |
---|---|
documentation |
RSZ1 - ZWave |
{% include base.html %}
This describes the Z-Wave device RSZ1, manufactured by Graber with the thing type UID of graber_rsz1_00_000
.
The RSZ1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the RSZ1 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Rollershutter | blinds_control | Blinds | Rollershutter |
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Battery Level | battery-level | Battery | Number |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
UP, DOWN, STOP
Provides start / stop control of blinds.
The blinds_control
channel supports the Rollershutter
item and is in the Blinds
category.
0-100
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The RSZ1 supports 1 association group.
Lifeline (primary controller) SWITCH MULTILEVEL REPORT after movement
BATTERY STATUS after movement or critical status
DEVICE RESET LOCALLY
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.