This describes the Z-Wave device HKZW-SO05, manufactured by Hank with the thing type UID of hank_so05_00_000
.
The HKZW-SO05 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Smart plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage. Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product's firmware upgrade.
HKZW-SO05 is a Smart Plug based on Z-Wave plus specification
The features list:
-
Supports 1xAC output and 2xUSB outputs;
-
AC output switch on/off by manual or Z-Wave command;
-
RGB LED indicates the Z-Wave network range;
-
RGB LED indicates the load power;
-
Z-Wave plus compatible (500 serials product);
-
supporting power meter;
-
supporting repeater role;
Supporting firmware OTA;
Automatic Z-Wave network inclusion:
-
Set the Z-Wave network main controller into inclusion mode.
-
Insert the Plug into a socket.
-
Auto-inclusion will be activated, i.e. Plug automatically starts looking for Z-Wave network controller. Auto-inclusion activation is signaled by a single, RGB LED indicator blink fast in blue.
-
Smart Plug should be recognized and automatically included into the Z-Wave network.
Manual Z-Wave network inclusion:
-
Connect the power supply.
-
Set the Z-Wave network main controller into inclusion mode.
-
Triple click the Z-button, RGB LED indicator should blink fast in blue.
-
Smart Plug should be recognized and included into the Z-Wave network.
Included as a secure device:
-
Connect the power supply.
-
Set the Z-Wave network main controller into secure inclusion mode.
-
Press and hold the Z-button for more than 3 seconds, RGB LED indicator should blink fast in green.
-
Smart Plug should be recognized and included into the Z-Wave security network.
To remove Smart Plug from the Z-Wave network:
-
Insert the plug into a socket.
-
Set the Z-Wave network main controller into exclusion mode.
-
Triple click the Z-button.
-
RGB LED indicator will blink orange till the removing process is completed, then the indicator will keep orange for 3 seconds.
The following table summarises the channels available for the HKZW-SO05 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Scene Number | scene_number | Number | |
Electric meter (kWh) | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
Electric meter (volts) | meter_voltage | Energy | Number |
Electric meter (amps) | meter_current | Energy | Number |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 10 configuration parameters available in the HKZW-SO05. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
20 | Overload Protection | Turn off if the load power exceeds 0.5A for more than 5s. |
21 | Device Status After Power Failure. | Define how the Plug reacts after the power supply is back on. |
24 | Load Status Change Notification | Send notification to associated devices when load is changed. |
27 | Indicator Modes | The RGB LED indicator will indicate the load. |
151 | Power Report Threshold | Power threashold for when to send reports to associated devices |
152 | Power Report Percentage Threshold | Percentage threshold for when to send report to associated devices |
171 | Power Report Frequence | The interval of sending power report to association device. |
172 | Energy Report Frequence | The interval of sending energy report to association device. |
173 | Voltage Report Frequency | The interval of sending voltage report to association device. |
174 | Electricity Report Frequency | The interval of sending electricity report to association device. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Turn off if the load power exceeds 0.5A for more than 5s.
The following option values may be configured -:
Value | Description |
---|---|
0 | Function Disabled |
1 | Function enabled |
The manufacturer defined default value is 1
(Function enabled).
This parameter has the configuration ID config_20_1_wo
and is of type INTEGER
.
This is a write only parameter.
Define how the Plug reacts after the power supply is back on.
The following option values may be configured -:
Value | Description |
---|---|
0 | Memorizes its state after a power failure |
1 | Always on after power failure. |
2 | Always off after power failure. |
The manufacturer defined default value is 0
(Memorizes its state after a power failure).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Send notification to associated devices when load is changed.
The following option values may be configured -:
Value | Description |
---|---|
0 | Function is disabled |
1 | Send Basic Report |
2 | Only when load condition is not changed by command. |
The manufacturer defined default value is 1
(Send Basic Report).
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
The RGB LED indicator will indicate the load.
The following option values may be configured -:
Value | Description |
---|---|
0 | Will work in indicator mode. |
1 | Indicate load for 5 seconds after load has changed. |
The manufacturer defined default value is 0
(Will work in indicator mode.).
This parameter has the configuration ID config_27_1
and is of type INTEGER
.
Power threashold for when to send reports to associated devices When the change value of the load power exceeds the threshold, the meter report is send to associated devices. 0 -- The function is disabled. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_151_2
and is of type INTEGER
.
Percentage threshold for when to send report to associated devices When the change value of the load power exceeds the threshold, the meter report is send to associated devices.
0 -- The function is disabled. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_152_1
and is of type INTEGER
.
The interval of sending power report to association device. The interval of sending power report to association device.
0 = The function is disabled. Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_171_4
and is of type INTEGER
.
The interval of sending energy report to association device. The interval of sending energy report to association device.
0 = The function is disabled. Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_172_4
and is of type INTEGER
.
The interval of sending voltage report to association device. The interval of sending voltage report to association device.
0 = The function is disabled. Values in the range 0 to 2678400 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_173_4
and is of type INTEGER
.
The interval of sending electricity report to association device. The interval of sending electricity report to association device.
0 = The function is disabled. Values in the range 0 to 2678400 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_174_4
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The HKZW-SO05 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Meter, Basic etc.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |