Skip to content

Latest commit

 

History

History
273 lines (163 loc) · 9.14 KB

00110001_1_0.md

File metadata and controls

273 lines (163 loc) · 9.14 KB
layout title
documentation
SmartDimmer - ZWave

{% include base.html %}

SmartDimmer RAone SmartDimmer

This describes the Z-Wave device SmartDimmer, manufactured by INNOVUS with the thing type UID of innovus_00110001_01_000. This version of the device is limited to firmware versions above 1.0

The SmartDimmer supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the SmartDimmer -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Sensor (Power in watts) sensor_power Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Sensor (Power in watts)

Indicates the energy consumption (kWh).

The sensor_power channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the SmartDimmer. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 Maximum dim level Maximum dim level
1 Report node Report Node, reports changes in level to this node id. Disabled if 0.
2 B&O IR support B&O IR support is disabled if 0 otherwise enabled.
3 Dimming type Dimming Type, trailing edge enabled if 0 otherwise leading edge enabled.
4 Dimming level duration Dimming level duration
5 Set level duration Default Set Level Duration, how long time it takes to set one level in 0.01s.
6 Long dim duration Long dim duration
7 Touch press time Touch press time
8 Touch Multiple Press Time No specific usage in this product
9 Touch Hold Time Touch Hold Time
10 Network Update Interval Network Update Interval
11 Rediscover Interval Rediscover Interval, time between rediscoveries in 256 seconds. Disabled if 0.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 0: Maximum dim level

Maximum dim level Maximum Level, a limit on the maximum level the dimmer can reach. Levels larger than 99 will simply be interpreted as 99 ie. no limit. Values in the range 0 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 1: Report node

Report Node, reports changes in level to this node id. Disabled if 0.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: B&O IR support

B&O IR support is disabled if 0 otherwise enabled.

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (enabled).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Dimming type

Dimming Type, trailing edge enabled if 0 otherwise leading edge enabled.

The following option values may be configured -:

Value Description
0 Trailing edge
1 Leading edge

The manufacturer defined default value is 1 (Leading edge).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Dimming level duration

Dimming level duration Default Dimming Level Duration, how long time it takes to dim one level in 0.01s. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 8.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Set level duration

Default Set Level Duration, how long time it takes to set one level in 0.01s.

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Long dim duration

Long dim duration Long Dim Duration, time to use dimming to level 0 when double clicking. Format is the same as multilevel switch duration. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 158.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Touch press time

Touch press time Touch Press Time, time for presses to register as separate and not part of a sequence, measured in 0.01s. 0 is interpreted as a 1. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Touch Multiple Press Time

No specific usage in this product Touch Multiple Press Time, has no specific usage is this product, shouldn't be changed. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Touch Hold Time

Touch Hold Time Touch Hold Time, time for presses to register as being held down in 0.01s. 0 is interpreted as a 1. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 40.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Network Update Interval

Network Update Interval Network Update Interval, time between network updates in 256 seconds. Disabled if 0. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 168.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Rediscover Interval

Rediscover Interval, time between rediscoveries in 256 seconds. Disabled if 0.

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 2362.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The SmartDimmer supports 1 association group.

Group 1: Dimmer

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SWITCH_TOGGLE_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_METER_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_ASSOCIATION_V1

Documentation Links