layout | title |
---|---|
documentation |
SmartDimmer - ZWave |
{% include base.html %}
This describes the Z-Wave device SmartDimmer, manufactured by INNOVUS with the thing type UID of innovus_00110001_01_000
.
This version of the device is limited to firmware versions above 1.0
The SmartDimmer supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the SmartDimmer -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Sensor (Power in watts) | sensor_power | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Indicates the energy consumption (kWh).
The sensor_power
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 12 configuration parameters available in the SmartDimmer. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
0 | Maximum dim level | Maximum dim level |
1 | Report node | Report Node, reports changes in level to this node id. Disabled if 0. |
2 | B&O IR support | B&O IR support is disabled if 0 otherwise enabled. |
3 | Dimming type | Dimming Type, trailing edge enabled if 0 otherwise leading edge enabled. |
4 | Dimming level duration | Dimming level duration |
5 | Set level duration | Default Set Level Duration, how long time it takes to set one level in 0.01s. |
6 | Long dim duration | Long dim duration |
7 | Touch press time | Touch press time |
8 | Touch Multiple Press Time | No specific usage in this product |
9 | Touch Hold Time | Touch Hold Time |
10 | Network Update Interval | Network Update Interval |
11 | Rediscover Interval | Rediscover Interval, time between rediscoveries in 256 seconds. Disabled if 0. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Maximum dim level Maximum Level, a limit on the maximum level the dimmer can reach. Levels larger than 99 will simply be interpreted as 99 ie. no limit. Values in the range 0 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_0_1
and is of type INTEGER
.
Report Node, reports changes in level to this node id. Disabled if 0.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
B&O IR support is disabled if 0 otherwise enabled.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(enabled).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Dimming Type, trailing edge enabled if 0 otherwise leading edge enabled.
The following option values may be configured -:
Value | Description |
---|---|
0 | Trailing edge |
1 | Leading edge |
The manufacturer defined default value is 1
(Leading edge).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Dimming level duration Default Dimming Level Duration, how long time it takes to dim one level in 0.01s. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Default Set Level Duration, how long time it takes to set one level in 0.01s.
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Long dim duration Long Dim Duration, time to use dimming to level 0 when double clicking. Format is the same as multilevel switch duration. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 158
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Touch press time Touch Press Time, time for presses to register as separate and not part of a sequence, measured in 0.01s. 0 is interpreted as a 1. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
No specific usage in this product Touch Multiple Press Time, has no specific usage is this product, shouldn't be changed. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Touch Hold Time Touch Hold Time, time for presses to register as being held down in 0.01s. 0 is interpreted as a 1. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 40
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Network Update Interval Network Update Interval, time between network updates in 256 seconds. Disabled if 0. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 168
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Rediscover Interval, time between rediscoveries in 256 seconds. Disabled if 0.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 2362
.
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The SmartDimmer supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SWITCH_TOGGLE_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.