layout | title |
---|---|
documentation |
NZW30S - ZWave |
{% include base.html %}
This describes the Z-Wave device NZW30S, manufactured by Inovelli with the thing type UID of inovelli_nzw30s_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The NZW30S supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Turn ON/OFF manually or remotely via the Z-Wave controller
• Can be Included in multiple Groups and Scenes
• Compatible with all incandescent and CFL/ LED bulbs
• Blue LED indicates switch location in a dark room
• Z-Wave Certified for simple pairing and integrated home automation
• Screw Terminal Installation — requires wiring connections for Line (Hot), Load, Neutral.
AUTO-INCLUSION! PLEASE READ.
PLEASE NOTE: This product is equipped with auto-inclusion to make your life easier. However, please read below to make sure you set it up properly:
- Please DO NOT switch on your power until you are physically including the switch to [your controller] as auto-inclusion will time-out in 30 seconds
- If successful, the switch will blink twice
- If unsuccessful, please use the backup method, which is to press the top button 6x within 2 seconds
- Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.
- Once the controller is ready to Exclude your device, press the B button 6 times within two seconds.
- Manual removal by pressing B button 5 seconds after shutting power off and turning it back on)
The following table summarises the channels available for the NZW30S -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Scene Number | scene_number | Number |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
The following table provides a summary of the 3 configuration parameters available in the NZW30S. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | LED ON - Switch ON | LED Indicator. Default = Switch On / LED Off |
4 | Invert | Invert switch |
5 | Countdown | Countdown Timer |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
LED Indicator. Default = Switch On / LED Off
The following option values may be configured -:
Value | Description |
---|---|
0 | Switch On / LED On |
1 | Switch Off / LED On |
2 | Disable LED |
The manufacturer defined default value is 0
(Switch On / LED On).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Invert switch To change the top of the switch to OFF and the bottom to ON. The following option values may be configured -:
Value | Description |
---|---|
0 | Up=On, Down=Off |
1 | Up=Off, Down=On |
The manufacturer defined default value is 0
(Up=On, Down=Off).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Countdown Timer Value 0 (default) = No Timer
Range = 0 - 32768 Seconds Values in the range 0 to 32768 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The NZW30S supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. An association command class that allows the device to communicate with other Z-Wave devices directly -- such as sending BASIC REPORT whenever the switch is turned on or off.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.