layout | title |
---|---|
documentation |
NZW37 - ZWave |
{% include base.html %}
This describes the Z-Wave device NZW37, manufactured by Inovelli with the thing type UID of inovelli_nzw37_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The NZW37 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Remotely control 2 individual Smart Outlets
Press the Middle Button on the front of your NZW37 3-5 times within 3 seconds to activate inclusion
Press the Middle Button on the front of your NZW37 3-5 times within 3 seconds to activate exclusion
The following table summarises the channels available for the NZW37 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Switch 1 | switch_binary1 | Switch | Switch |
Switch 2 | switch_binary2 | Switch | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Switch the power on and off.
The switch_binary1
channel supports the Switch
item and is in the Switch
category.
Switch the power on and off.
The switch_binary2
channel supports the Switch
item and is in the Switch
category.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The NZW37 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 2 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.