layout | title |
---|---|
documentation |
914TRL - ZWave |
{% include base.html %}
This describes the Z-Wave device 914TRL, manufactured by Black & Decker with the thing type UID of kwikset_914trl_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The 914TRL supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The following table provides a reference of the Alarm_Number related messages.
Alarm Type Alarm Level Notification Event
021 001 Lock Secured using Keyed cylinder or inside thumb-turn
022 001 Lock Un-Secured using Keyed cylinder or inside thumb-turn
026 001 Lock Auto Secured – Bolt Jammed (Not fully extended)
027 001 Lock Auto Secured – Successful (Fully extended)
017 001 Lock Secured at Keypad – Bolt Jammed (Not fully extended)
018 000 or User-ID#* Lock Secured at Keypad – Successful (Fully extended)
019 User-ID#* Lock Un-Secured by User (User-ID) at Keypad
023 001 Lock Secured by Controller – Bolt Jammed (Not fully extended)
024 001 Lock Secured by Controller – Successful (Fully extended)
025 001 Lock Un-Secured by Controller – Successful (Fully retracted)
112 User-ID#* New User Code (User-ID#) added to the lock
032 001 All User Codes deleted from lock
161 001 Failed User Code attempt at Keypad
162 User-ID#* Attempted access by user (User-ID#) outside of scheduled
167 001 Low battery level
168 001 Critical battery level
169 001 Battery level too low to operate lock
* User-ID# values: 001 to 030
Press button “A” on the lock one time to include it in your system.
Press button “A” on the lock one time to exclude it in your system.
The following table summarises the channels available for the 914TRL -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Door Lock | lock_door | Door | Switch |
Alarm | alarm_number | Number | |
Alarm Raw | alarm_raw | String | |
Battery Level | battery-level | Battery | Number |
Lock and unlock the door.
The lock_door
channel supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Provides the raw alarm value.
The alarm_number
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Provides the raw alarm status information including alarm type and level in the following json format: {"type":"ACCESS_CONTROL","event":"6","status":"255"}
Provides alarm parameters as json string.
The alarm_raw
channel supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 4 configuration parameters available in the 914TRL. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
31 | Auto Buzzer | Beeping sound enabled. |
31 | Auto Lock | Automatically re-locks door 30 seconds after unlocking. |
31 | Lock LED Status | Door lock status LED blinks every 6 seconds. |
40 | Factory Default | Reset to factory default settings. |
Lock Timeout | Sets the time after which the door will auto lock |
Beeping sound enabled. Beeping sound enabled. When disabled, keypad buttons light red or amber when pressed.
ON position is factory default.
Note: It is recommended that the beeping sound is enabled during programming. The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(ON).
This parameter has the configuration ID config_31_1_00100000
and is of type INTEGER
.
This is a read only parameter.
Automatically re-locks door 30 seconds after unlocking. Lock automatically re-locks door 30 seconds after unlocking. OFF position is factory default. If this switch is turned on, it will be disabled if all codes are deleted from the lock. The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 0
(OFF).
This parameter has the configuration ID config_31_1_01000000
and is of type INTEGER
.
This is a read only parameter.
Door lock status LED blinks every 6 seconds. Door lock status LED blinks every 6 seconds. ON position is factory default. The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(ON).
This parameter has the configuration ID config_31_1_10000000
and is of type INTEGER
.
This is a read only parameter.
Reset to factory default settings. Reset factory default settings, except for the anti-theft setting.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
1 | Factory Default |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_40_1_wo
and is of type INTEGER
.
This is a write only parameter.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 914TRL supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_LOCK_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
- Z-Wave Configuration and Association Parameters
- User Guide
- Installation Guide
- Application Note - Kwikset Home Connect
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.