layout | title |
---|---|
documentation |
NGD00Z-4 - ZWave |
{% include base.html %}
This describes the Z-Wave device NGD00Z-4, manufactured by Linear Corp with the thing type UID of linear_ngd00z4_00_000
.
The device is in the category of Garage Door, defining Garage Door.
The NGD00Z-4 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
GARAGE DOOR OPENER REMOTE COMMAND TRANSCEIVER with TILT SENSOR
TO INCLUDE THE GD00Z-4 INTO YOUR CONTROLLER
- Place your Z-Wave Controller into Discovery or Include mode.
- Press and release the link button on the GD00Z-4.
- Confirm that the GD00Z-4 was recognized by your Z-Wave Controller.
TO EXCLUDE THE GD00Z-4 FROM YOUR CONTROLLER
- Place your Z-Wave Controller into Exclude mode.
- Press and release the link button on the GD00Z-4.
- Confirm that the GD00Z-4 was excluded by your Z-Wave Controller.
The following table summarises the channels available for the NGD00Z-4 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Barrier State | barrier_state | Door | Number |
Alarm (raw) | alarm_raw | String |
Send 0 to CLOSE the Garage Door
Send 255 to OPEN the Garage Door
Reading this value provides the Status of the Garage Door. Status values are:
0 = Closed
252 = Closing
253 = Stopped
254 = Opening
255 = Open
Indicates the state of the barrier.
The barrier_state
channel supports the Number
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Closed |
252 | Closing |
253 | Stopped |
254 | Opening |
255 | Open |
Provides the raw alarm status information as a string, including alarm type and level, in the following json format: {"type":"ACCESS_CONTROL","event":"6","status":"255"}
Provides alarm parameters as json string.
The alarm_raw
channel supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The NGD00Z-4 supports 1 association group.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_BARRIER_OPERATOR_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.