PD300EMZ5-1 300 Watt, Plug-In Dimmer Series 500

This describes the Z-Wave device PD300EMZ5-1, manufactured by Linear Corp with the thing type UID of linear_pd300emz5_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

PD300EMZ5-1 product image

The PD300EMZ5-1 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The GoControl PD300EMZ5-1 Plug-in Lamp Module is designed to provide Z-Wave control to a connected dimmable lamp. The PD300EMZ5-1 module is plugged into any standard grounded AC wall outlet, and the lamp is then plugged into the module. Once connected, the lamp can be dimmed or turned on or off remotely via the Z-Wave controller. The module contains two power receptacles - one controlled, and one pass-through (powered at all times).

This Plug-in Lamp Module integrates with other Nortek Security & Control Z-Wave enabled products, and can also act as a wireless repeater to ensure that commands intended for another device in the network are received (useful when a device would otherwise be out of radio range).

Auto-Sense

Unique to Nortek Security & Control, the Auto-Sense feature allows for local lamp activation independent of the Z-Wave controller status. With AutoSense, one can simply switch the connected lamp's manual switch off, then on, and AutoSense will instruct the PD300EMZ5-1 to turn the lamp on.

Specifications

  • Signal (Frequency): 908.42 MHz
  • Maximum Load:
    Incandescent: 300W maximum, 120 VAC
  • Range: Up to 100 feet line of sight between the wireless controller and/or the closest Z-Wave device
  • Network wide inclusion
  • One controlled and one pass-through outlet
  • Security beaming

Inclusion Information

Refer to your Controller operating instructions to add this switch under the command of the Wireless Controller.

  1. With your Controller in Discovery or Add Mode, tap the button on the face of the outlet. The LED will blink slowly when in ADD Mode.
  2. You should see an indication on your Controller that the "device was added" to the network and the LED will stop blinking.
  3. The device will appear in the list of Switches. It should display as a switch.
    If the Controller/Gateway shows the addition failed, repeat Steps 1-3.

NOTE: If you have trouble adding the PD300EMZ5-1 to a group it may be that the Home ID and Node ID were not cleared from it after testing. You must first "RESET UNIT" to remove it from the network. Although adding it to a group includes it in the network, removing it from a group does not remove it from the network. If removed from a group, it functions as a repeater (only). "RESET UNIT" removes it completely from the network.

Exclusion Information

To Reset Unit (If Required):
In the event that your primary Controller is lost or otherwise inoperable, to reset the PD300EMZ5-1 and clear all network information, follow these steps:

  1. Tap the button on the face of the outlet five (5) times.
  2. Press and hold the button for 15 seconds. The LED will increasingly blink faster to indicate that a Reset is taking place.

Removing from a network:
The PD300EMZ5-1 can be removed from the network by the Controller / Gateway. Refer to the Controller operating instructions for details.

  1. Set the Controller into Removal Mode and follow its instruction to delete the PD300EMZ5-1 from the Controller.
  2. Remove the switch by tapping the button on the face of the outlet 2 times. The LED will begin blinking slowly for 10 seconds indicating that it has been removed.
  3. You should see an indication on your Controller that the "device was removed" from the network.

Wakeup Information

The PD300EMZ5-1 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Channels

The following table summarises the channels available for the PD300EMZ5-1 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number Number
Electric meter (amps) meter_current Energy Number
Electric meter (volts) meter_voltage Energy Number
Electric meter (watts) meter_watts Energy Number
Electric meter (kWh) meter_kwh Energy Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 11 configuration parameters available in the PD300EMZ5-1. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 LED Intensity How bright the device LEDs should be
3 Night Light LED "Night Light" behavior
7 Remote Dim Step How many levels the dimmer will change each time the Dim Timer expires
8 Remote Dim Time How often the dim level will change (in 10 ms resolution)
9 Local Dim Step How many levels the dimmer will change each time the Dim Timer expires
11 Power Monitoring Provide a visual display of the ammount of energy being consumed
12 Energy display duration Number of seconds LED displays power level usage
13 Engery report frequency Number of minutes between automatic reporting
16 Local Dim Time How often the dim level will change (in 10 ms resolution)
17 AllSwitch Dim Step How many levels the dimmer will change each time the Dim Timer expires
18 AllSwitch Dim Time How often the dim level will change (in 10 ms resolution)
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 2: LED Intensity

How bright the device LEDs should be 0 = OFF, 1 = Very Dim, 100 = Full Brightness (default) Values in the range 0 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Night Light

LED "Night Light" behavior

The following option values may be configured -:

Value Description
0 LED on when load is on, off when load is off
1 LED off when load is on, on when load is off
2 LED is always on
3 LED is always off

The manufacturer defined default value is 1 (LED off when load is on, on when load is off).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 7: Remote Dim Step

How many levels the dimmer will change each time the Dim Timer expires

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Remote Dim Time

How often the dim level will change (in 10 ms resolution)

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Local Dim Step

How many levels the dimmer will change each time the Dim Timer expires

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 11: Power Monitoring

Provide a visual display of the ammount of energy being consumed The PD300EMZ5-1 provides a visual display of the amount of energy being consumed when the switch is turned on by illuminating the LEDs in one of 5 different colors.

<td>
   
</td>
<td>
  White
</td>
<td>
  Green
</td>
<td>
  Blue
</td>
<td>
  Yellow
</td>
<td>
  Red
</td>
Energy
0 to 2 Watts
3 to 60 Watts
60 to 100 Watts
101 to 200 Watts
201 to 300 Watts

The Power Monitoring can be turned off utilizing Parameter 11. When turned off, the PD300EMZ5-1 will no longer illuminate the LED to indicate any energy use and periodic reports to the hub on energy use will also be turned off. The following option values may be configured -:

Value Description
0 Power Monitoring Off
1 Power Monitoring On

The manufacturer defined default value is 1 (Power Monitoring On).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Energy display duration

Number of seconds LED displays power level usage The duration the LED will change color to indicate the amount of energy being used can be set using Parameter 12. After displaying the "energy used" color, the LED will revert to OFF or ON (white) as determined by configuration parameter #3. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 13: Engery report frequency

Number of minutes between automatic reporting 0: Automatic reporting OFF

1-255: Number of minutes between automatic reporting Values in the range 0 to 255 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_13_2 and is of type INTEGER.

Parameter 16: Local Dim Time

How often the dim level will change (in 10 ms resolution)

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_16_2 and is of type INTEGER.

Parameter 17: AllSwitch Dim Step

How many levels the dimmer will change each time the Dim Timer expires

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: AllSwitch Dim Time

How often the dim level will change (in 10 ms resolution)

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_18_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PD300EMZ5-1 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links